background image

Holmes Ecowater 

Phone 403-327-7867 / Toll Free 877-327-9007 

925 – 2 A Ave. N. 

Lethbridge, AB 

mailto:[email protected]

 

 

  

REPLACING PREFILTER AND POSTFILTER CARTRIDGES 

 
When  replacing  cartridges,  you  can  keep  the  RO  assembly  wall  mounted,  or  simply  lift  from  the  mounting 
screws and lay in a leak-proof container on the cabinet floor. 
 

1. CAUTION: 

Before removing cartridges, be sure to close the 

water supply valve 

to the RO, and the 

shutoff 

valve 

on the storage tank. Then, open the RO faucet until 

pressure is relieved 

and water flow stops. 

2. Turn (1/4 turn to the left) and pull downward either or both cartridges from the RO head assembly. 
3. Remove new cartridge(s) from the sanitary bag. Be sure O-ring seals on top of cartridge are lubricated. Use 
silicone grease approved for use on potable water supplies. 
4. Insert the top end of either or both cartridges into the applicable head, push upward and rotate 1/4 turn to 
the right to lock in place. 

Be sure to locate the prefilter to the right and the postfilter to the left, as shown. 

5. Turn on the water supply and check for leaks. 
 
  

REPLACING RO MEMBRANE CARTRIDGE 

 

1. CAUTION: 

Before removing the cartridge, be sure to close the 

water supply valve 

to the RO, and the 

shutoff 

valve 

on the storage tank. Then, open the RO faucet until 

pressure is relieved 

and water flow stops. 

2. Be sure there is some slack in the red flow control drain tubing, shown in the figure, above. Then, turn (1/4 
turn to the left) the cartridge and pull downward. 
3. Depress the elbow fitting collet with a finger while carefully pulling the red tubing out. 
4. Remove the new RO cartridge from the sanitary bag. Rinse the cartridge in fresh tap water and dry. Depress 
the elbow fitting collet and remove the plug. 
5.  Remove  the  protective  cap  (not  shown)  from  the  top  end  of  the  cartridge.  Be  sure  the  o-ring  seals  are 
lubricated. Use silicone grease approved for use on potable water supplies. 
6. Inspect the end of the red flow control tubing for nicks, scratches or other rough spot. If needed, use a sharp 
knife and carefully cut 1/4" from the end of the tubing. Check to be sure the center hole is unobstructed. 
7.  Insert the end of the tubing into the elbow fitting on the new RO  cartridge. Gently pull on the tubing to be 
sure it is secure. 
8.  Insert  the  top  end  of  the  cartridges  into  the  head,  push  upward  and  rotate  1/4  turn  to  the  right  to  lock  in 
place. 

Be sure to locate the RO cartridge in the center, as shown. 

9. Turn on the water supply and check for leaks at the top, and at the red tubing connection. 
10.  Purge  the  cartridge.  The  RO  Cartridge  contains  a  food  grade  preservative  that  you  should  clean  from  it 
before using water from the system. The preservative will give the product water an unpleasant taste and odor. 
After  the  storage  tank  has  filled  (takes  about  4  hours).  Open  the  RO faucet  until  the  tnak  is  empty  and  flow 
stops. Close the RO faucet and allow the tank to fill again for 4 hours. Then, open the RO faucet and empty 
again. After purging 4 times, the system is ready to make product water for use. 

Содержание ERO335

Страница 1: ...ften than 6 months if it begins to plug with sediments If the water has sediments only with no chlorine you may notice a slower making of product water as the prefilter collects the sediments When this occurs replacement is needed to restore full flow Postfiliter Cartridge The carbon postfilter removes any remaining taste and or odors from the product water before it goes to the RO faucet Replace ...

Страница 2: ...en turn 1 4 turn to the left the cartridge and pull downward 3 Depress the elbow fitting collet with a finger while carefully pulling the red tubing out 4 Remove the new RO cartridge from the sanitary bag Rinse the cartridge in fresh tap water and dry Depress the elbow fitting collet and remove the plug 5 Remove the protective cap not shown from the top end of the cartridge Be sure the o ring seal...

Страница 3: ...e storage tank is completely empty and the bleach odor is gone 9 Close the RO faucet after water flow stops LEAK AT FAUCET If the sink p trap is used as the drain point RO reject water is routed to the faucet air gap through 1 4 tubing It gravity drains from the faucet through 3 8 tubing to the drain point The hole in the faucet body below the lever is the air gap vent If the 3 8 tubing is restric...

Страница 4: ...Holmes Ecowater Phone 403 327 7867 Toll Free 877 327 9007 925 2 A Ave N Lethbridge AB mailto tech holmeswater com MAINTENANCE RECORD Date PreFIlter Post Filter Membrane Sanitized ...

Отзывы: