Required or replaced products or components shall be returned surface freight. In genuine emergency situations, 
Manufacturer will at Manufacturer

’s sole discretion) forward replacement parts to Customer without waiting for 

authorized  return  of  the  questionable  part(s).  In  such  cases,  Customer  will  issue  a  purchase  order  or  other 
payment  guarantee  prior  to  shipment.  If  the  returned  part  is  found  to  have  been  misused  or  abused,  or  the 
defective  part  is  not  received  by  Manufacturer  within  thirty  (30)  days;  the  Customer  will  be  invoiced  for  the 
replacement  part(s)  provided.  This  Warranty  does  not  cover  or  include  labor  and/or  travel  to  the  Customer

’s 

premise  or  location  or  any  other  location.  Charges  of  $1000  per  day  plus  associated  travel  expenses  will  be 
incurred  by  the  Customer  in  providing  the  Warranty  Service  at  any  location  other  than  Manufacturer

’s  main 

headquarters;  that  is  if  the  Manufacturer  deems  that  the  product  is  not  covered  by  said  Warranty.  The 
Manufacturer  reserves  the  right  to  precondition  such  travel  to  Customer

’s  premises  upon  prepayment  of 

Manufacturer

’s anticipated costs of attending such premises. 

Voidability of Warranty 

This Warranty  shall  be  void  and  unenforceable  as  to  any  Manufacturer  product  which  has  been  damaged  by 
accident, mishandling, abuse or has been repaired, modified, altered, disassembled or otherwise tampered with 
by anyone other than Manufacturer or an authorized Manufacturer service representative; or, if any replacement 
parts are not authorized by Manufacturer have been used, or, the product has not been installed, operated and 
maintained in strict accordance and adherence with the operating documentation and manuals for such product. 
Any expressed Warranty, or similar representation of performance set forth in the operation documentation for 
media or resin incorporated into a product by the Manufacturer shall be void and unenforceable unless the feed 
water  requirements  set  forth  in  the  operating  documentation  for  such  product  are  unequivocally  and  strictly 
adhered to. 

Limitations and Exclusions 

THIS WARRANTY  AND  REMEDIES  DESCRIBED  HEREIN  AND  HEREINABOVE  ARE  EXCLUSIVE  AND  IN 
LIEU  OF  ANY  AND  ALL  OTHER  WARRANTY  OR  REMEDIES,  EXPRESSED  OR  IMPLIED,  INCLUDING 
WITHOUT  LIMITATION,  ANY  IMPLIED  WARRANTY  OF  MERCHANTABILITY  OR  FITNESS  FOR  A 
PARTICULAR  PURPOSE.  IN  NO  EVENT  SHALL  THE  MANUFACTURER  BE  LIABLE  FOR  ANY 
CONSEQUENTIAL,  INCIDENTAL  OR  OTHER  SIMILAR  TYPES  OF  DAMAGES,  FOR  DAMAGES  FOR  THE 
LOSS OF PRODUCTION OR PROFITS, OR INJURY TO PERSON OR PROPERTY. NO PERSON HAS ANY 
AUTHORITY TO BIND THE MANUFACTURER TO OTHER THAN WHAT IS SET FORTH ABOVE. 

THIS WARRANTY GIVES THE CUSTOMER SPECIFIC LEGAL RIGHTS AND THE CUSTOMER MAY ALSO 
HAVE OTHER RIGHTS WHICH VARY FROM JURISDICTION TO JURISDICTION. THE PARTIES RECOGNIZE 
AND AGREE, THAT IN ALL RESPECTS THE LAWS OF THE STATE OF CALIFORNIA SHALL APPLY TO AND 
SHALL GOVERN ANY INTERPRETATION OR LEGAL SIGNIFICANCE OF THIS DOCUMENT. 

NO  WARRANTY  OR  OTHER  LIABILITY  OF  THE  MANUFACTURER  TO  CUSTOMER  UNDER  THIS 
AGREEMENT  OR  OTHERWISE  WILL  IN  ANY  EVENT  EXCEED  THE  COST  OF  REPLACEMENT  OF  THE 
APPLICABLE MANUFACTURER PRODUCT, PART, OR ACCESSORY THAT IS SUBJECT TO ANY BREACH 
OF MANUFACTURER

’S WARRANTY. MANUFACTURER WILL NOT BE LIABLE FOR ANY DAMAGE TO ANY 

PROPERTY  OF  CUSTOMER  OR  TO  CUSTOMER

’S  CUSTOMERS  FOR  ANY  CONSEQUENTIAL, 

INCIDENTAL,  OR  ECONOMIC  LOSS  OR  COMMERCIAL  DAMAGE  WHATSOEVER.  REMEDIES  HEREIN 
PROVIDED  ARE  EXPRESSLY  MADE  THE  SOLE  AND  EXCLUSIVE  REMEDIES  FOR  BREACH  OF  ANY 
WARRANTY OR OTHER OBLIGATION HEREUNDER EXPRESS OR IMPLIED OR FROM THE OPERATION 
OF LAW. 

 

Содержание ELC-1500

Страница 1: ...Membrane System User Manual ELC Series ELC 1500 w...

Страница 2: ...ELC Series User Manual MKTF 506 A 2 03 18 This page intentionally left blank...

Страница 3: ...ICATION 11 MEMBRANE INSTALLATION REMOVAL AND REPLACEMENT 13 INITIAL START UP 17 OPERATING DO S AND DON TS 18 RO SHUT DOWN PROCEDURE 18 PRODUCT SPECIFICATIONS 19 OPERATING LIMITS 20 OPERATION AND MAINT...

Страница 4: ...of operation or if the feedwater conditions change please contact your local dealer or distributor to determine the proper recovery for your application IN ORDER TO MAINTAIN THE MANUFACTURER S WARRANT...

Страница 5: ...Y CAUTION WARNING OR OTHER DESCRIPTIVE LABELS FROM THE SYSTEM PLEASE READ THE ENTIRE MANUAL BEFORE PROCEEDING WITH THE INSTALLATION AND START UP FAILURE TO FOLLOW INSTRUCTIONS OR OPERATING PARAMETERS...

Страница 6: ...WARRANTY OPERATING LIMITS Operating Parameters Feed Temperature 40 85 F System Inlet Pressure 40 60 psi Maximum Operating Pressure at 77 F 90 psi Feedwater Requirements Maximum SDI Rating 3 Maximum Tu...

Страница 7: ...ot pass through the membrane To calculate the percentage of rejection use the following formula Rejection Feed TDS Product TDS Feed TDS x 100 Example 98 5 550 8 25 550 x 100 ALL TDS FIGURES MUST BE EX...

Страница 8: ...ed storage tank locate the 3 8 quick connect tubing fitting labeled holding tank on the right side of the frame Attach 3 8 tubing and connect it to the pressurized storage tank Ensure that the permeat...

Страница 9: ...tch turns the system on when the water level in the tank drops and off when the tank is full Should you choose a liquid switch s for your application it can be obtained by your local dealer or distrib...

Страница 10: ...re vessel housing is 30 psi 2 1 bar Avoid static permeate side backpressure at all times Under certain conditions the presence of free chlorine chloramines and other oxidizing agents will cause premat...

Страница 11: ...ELC Series User Manual MKTF 506 A 11 03 18 SYSTEM IDENTIFICATION Figure 1...

Страница 12: ...INLINE DM 2 1 2 QC HM DIGITAL 203385 750 1500 9 GAUGE PM GLY FILL 0 100 PSI BAR 2 5 DIA 1 4 MNPT AXEON 204165 750 1500 10 VALVE SOLENOID N C UL 110V 1 2 FNPT 3 METER CORD GC 204909 750 1500 11 METER F...

Страница 13: ...OM THE SYSTEM 1 Disconnect the tubing from the bottom of the membrane housing Unscrew the membrane from the system 2 Remove the replacement membrane element s from the shipping box the membrane s shou...

Страница 14: ...old membrane element out of the membrane element housing 3 Lubricate the brine seal and o rings with a non petroleum based lubricant such as Dow Corning 111 Do not use a petroleum based lubricant 4 In...

Страница 15: ...ELC Series User Manual MKTF 506 A 15 03 18 Figure 2...

Страница 16: ...ELC Series User Manual MKTF 506 A 16 03 18 Figure 3...

Страница 17: ...Figure 1 Page 11 2 Fully close the concentrate recycle valve by turning it clockwise 14 Figure 1 Page 11 3 Plug the RO system in and adjust the concentrate waste valve and recycle valve to the design...

Страница 18: ...ystem for extended periods Operate the system with insufficient feed flow Operate the pump dry RO SHUT DOWN PROCEDURE 1 Purge system See Initial Start up instructions 2 Turn off feed supply water from...

Страница 19: ...e Size 3018 3018 Vessels Vessel Array 1 1 1 Vessel Quantity 1 2 Pumps Pump Type Rotary Vane 401 Low Lead Brass Rotary Vane 601 Low Lead Brass Motor HP 1 3 HP 1 2 HP RPM at 60 HZ 1725 1725 System Elect...

Страница 20: ...essure vessel housing is 30 psi 2 1 bar Avoid static permeate side backpressure at all times Under certain conditions the presence of free chlorine chloramines and other oxidizing agents will cause pr...

Страница 21: ...ese flow meters indicate the flow rates of the permeate concentrate and recycle water The measurements when added together also indicate the feedwater flow rate or total flow rate EXCESSIVE RECYCLING...

Страница 22: ...low these steps 1 The system must be operating during the flush procedure 2 Fully open the concentrate valve by turning it counter clockwise 12 Figure 1 Page 11 3 Allow the system to run for 10 to 20...

Страница 23: ...essure vessel being filled For cold weather winter storage add 20 by weight Polyglycol to the 2 M 100 solution Add Polyglycol AFTER the 2 M 100 solution has been mixed 2 Separate the preservation solu...

Страница 24: ...er temperature See temperature correction sheet Poor Permeate Quality Low operating pressure See low inlet pressure Damage product tube o rings Inspect and or replace Damaged or oxidized membrane Repl...

Страница 25: ...hin 20 of the rated production after correcting the feedwater temperatures above or below 77 F Check the permeate flow meter to determine the permeate flow rate TO DETERMINE THE TEMPERATURE CORRECTION...

Страница 26: ...ELC Series User Manual MKTF 506 A 26 03 18 OPERATING LOG...

Страница 27: ...RRECTION FACTORS FOR MEMBRANE Find the temperature correction factor TCF from the table below Divide the rated permeate flow at 77 F by the temperature correction factor The result is the permeate flo...

Страница 28: ...rection table to obtain the correct flow Example 5 gpm at 59 F 5 1 42 3 52 gpm 5 gpm at 77 F 5 1 5 gpm 5 gpm at 84 F 5 0 89 5 62 gpm SERVICE ASSISTANCE If service assistance is required Contact your l...

Страница 29: ...C Series User Manual MKTF 506 A 29 03 18 MODELS ELC 750 ELC 1500 A DIM 36 62 36 62 B DIM 17 20 17 20 C DIM 17 00 17 00 D DIM 15 00 15 00 E DIM 12 00 12 00 F DIM 11 76 11 76 SYSTEM DRAWINGS FLOW DIAGRA...

Страница 30: ...ELC Series User Manual MKTF 506 A 30 03 18 ELC 750 FLOW DIAGRAM...

Страница 31: ...ELC Series User Manual MKTF 506 A 31 03 18 ELC 1500 FLOW DIAGRAM...

Страница 32: ...ELC Series User Manual MKTF 506 A 32 03 18 ELC SERIES ELECTRICAL SCHEMATIC...

Страница 33: ...thin three 3 months of shipment from the Manufacturer s manufacturing facility In no event shall the Warranty Commencement Date exceed three 3 months from the shipment from Manufacturer s facility The...

Страница 34: ...n and manuals for such product Any expressed Warranty or similar representation of performance set forth in the operation documentation for media or resin incorporated into a product by the Manufactur...

Отзывы: