background image

Water specialist disc valve

programming and service manual

Руководство по настройке и эксплуатации 

управляющего клапана для систем очистки воды 

Ecosoft WS1 DV

Содержание WS1 DV

Страница 1: ...Water specialist disc valve programming and service manual Руководство по настройке и эксплуатации управляющего клапана для систем очистки воды Ecosoft WS1 DV ...

Страница 2: ...CERTIFICATES OF ECOSOFT СЕРТИФИКАТЫ ECOSOFT 9001 2015 ...

Страница 3: ...em Setup 11 9 OEM Installer Settings 13 10 Diagnostics 14 11 Internal Components 16 12 Front Cover and Drive Assembly 17 13 Injector Cap Injector Screen Injector Plug and O Ring 18 14 Injector Order Information 19 15 Refill Flow Control Assembly and Refill Port Plug 20 16 Drain Line 21 17 Drain Line Flow Control and Fitting Assembly 22 18 Water Meter Meter Plug and Mixing Valve 23 19 Installation ...

Страница 4: ...nuts or caps Do not place a screwdriver in the slots on caps and or tap with a hammer Do not use pipe dope or other sealants on threads Use Tefl on tape on the threaded inlet outlet and drain fi ttings Tefl on tape is not necessary on the nut connection or caps because of o ring seals After completing any valve maintenance involving the drive assembly or the drive cap assembly unplug power source ...

Страница 5: ...able of routing the flow of water in the necessary paths to regenerate or backwash water treatment systems The injector regulates the flow of brine or other regenerants The control valve regulates the flow rates for backwashing rinsing and the replenishing of treated water into a regenerant tank when applicable The control valve uses no traditional fasteners e g screws instead clips threaded caps ...

Страница 6: ... the control is in the User Display Then simultaneously press NEXT and REGEN or unplug power source plug on the circuit board wait approximately 3 seconds and plug back in 3 BUTTON OPERATION AND FUNCTION or UP or DOWN Either button changes the value of the setting being viewed NEXT 1 Moves to the next display 2 While viewing Time of Day press and hold for 3 seconds to change the time of day REGEN ...

Страница 7: ...s set reserve capacity is zero The control valves can be set to regenerate immediately or at the next regeneration time by changing the Regeneration Type Option Step 3S There are three choices for settings 1 DELY means regeneration will occur at the preset regeneration time 2 On 0 means regeneration will occur when the gallons capacity reaches zero 3 RES means the regeneration will occur at the pr...

Страница 8: ... capacity reaches 0 Soft Delayed OFF 1 28 days Time Clock operation Regeneration occurs at the next regeneration time the specified number of days is reached Soft On 0 02 5700 m3 1 28 days Regeneration occurs immediately when volume capacity reaches 0 or the specified number of days is reached whichever comes first Soft On 0 02 5700 m3 OFF Regeneration occurs immediately when volume capacity reach...

Страница 9: ...n water is flowing Display of the error code for the type of failure detected by the control Code Description of Error 101 Unable to start motor output energized but no movement 102 Valve motor stalled unable to find proper park position 103 Valve motor ran too long unable to fi nd proper park position 104 Valve unable to find home position Display shown when programming is LOCKED Display shown wh...

Страница 10: ...IME OF DAY From the Time of Day display press and hold NEXT until the SET indicator and the hour flash Use UP or DOWN to set the hour Press NEXT to go to the next display Use UP or DOWN to set the minutes Press NEXT to return to user level displays RETURN TO NORMAL MODE ...

Страница 11: ... STEP 5S STEP 6S ST ST ST ST ST RETURN TO NORMAL MODE STEP 4S STEP 4S Ionic Capacity Use UP or DOWN to select Ionic Capacity kg of CaCO2 This display appears if Step 3S is set to RES If DELY or ON 0 is selected in Step 3S Volume Capacity can be set from 0 02 m3 5700 m3 or OFF Press NEXT to go to Step 5S Press REGEN to return to previous step STEP 1S STEP 2S STEP 3S STEP 4S STEP 5S STEP 6S ST ST ST...

Страница 12: ...t the length of the second backwash from 1 95 minutes or OFF using UP or DOWN This display will not appear if Step 2S is set to FLT1 Press NEXT to go to Step 10S Press REGEN to return to previous step STEP 7S STEP 8S STEP 9S STEP 10S STEP 11S RETURN TO NORMAL MODE STEP 10S STEP 10S Adjust the length of rinse from 1 95 minutes or OFF using UP or DOWN Press NEXT to go to Step 11S Press REGEN to retu...

Страница 13: ...will only be displayed when rES is selected in Step 3S Press NEXT to go to Step 4I Press REGEN to return to previous step STEP 4I STEP 4I Day Override Adjust day override from 1 28 days or OFF using UP or DOWN Press NEXT to go to Step 5I Press REGEN to return to previous step STEP 5I STEP 5I Time of Regeneration Hour Set the time hour for regeneration using UP or DOWN The default time is 2 00 a m ...

Страница 14: ...D Volume Since Last Regeneration Press NEXT to go to Step 5D PressREGEN to return to previous step STEP 5D STEP 5D Reserve Capacity Displays the actual reserve capacity calculated for yesterday This screen will only be displayed when rES is selected in step 3S Press NEXT to go to Step 6D Press REGEN to return to previous step STEP 6D STEP 6D Treated Water Usage Displays the volume of treated water...

Страница 15: ...t History Displays the motor drive current measured during the initial 0 5 seconds after leaving Brine Draw Measured every fifth regeneration up to 99 occurrences Press NEXT to go to Step 11D Press REGEN to return to previous step STEP 11D STEP 11D Error Log This display shows a history of the last 10 errors generated by the control during operation Press or to view each error recorded Press NEXT ...

Страница 16: ...0 DV Drive Shaft 1 8 V4125 DV Spring Support 1 9 V4135 DV Compression Spring 1 10 V4108 O ring 235 1 11 V4107 01 DV Main Cap Assembly 1 12 V4111 DV Lock Ring 1 13 V4114 DV Back Plate 1 14 V4152 DV Injector Cap 2 15 V4196 O ring 124 2 16 V3010 XX WS1 Injector Assembly 1 17 V4121 1Z DV Injector Asy Z Plug 1 18 V4120 DV Injector Screen 1 19 V4144 01 Elbow 3 8 Liquifit CV W RFC 1 20 V3962 WS1 Drn Elb ...

Страница 17: ...V Reduction Gear 9x48 1 3 V4116 DV Encoder Wheel 1 4 V4012 T1 DV Drive Gear Axle 1 5 V4117 DV Reduction Gear Axle 3 6 V4195 DV Reduction Gear 12x48 3 7 V4133 01 DV Drive Motor Asy JST 1 8 V3113 WS1 Spring Clip 1 9 V4123PI 01BOARD DV PI PCB 1 10 V4128 DV Encoder Guide Right 1 11 V4127 DV Encoder Guide Left 1 12 V4118 DV Drive Bracket 1 13 V4119 01W DV Front Cover Metric Asy White 1 ...

Страница 18: ...S1 Injector Asy D Red V3010 1E WS1 Injector Asy E White V3010 1F WS1 Injector Asy F Blue V3010 1G WS1 Injector Asy G Yellow V3010 1H WS1 Injector Asy H Green V3010 1I WS1 Injector Asy I Orange V3010 1J WS1 Injector Asy J Light Blue V3010 1K WS1 Injector Asy K Light Green Not Shown V3170 O ring 011 Not Shown V3171 O ring 013 The injector plug and the injector each contain one 011 lower and 013 uppe...

Страница 19: ...3010 1K Light Green 22 Actual tank size used may vary depending on the design and application of the system Tank diameter is an approximation for the following 1 Downfl ow softener using standard mesh synthetic cation exchange media regenerating with sodium chloride 2 Upflow softener using standard mesh synthetic cation exchange media regenerating with sodium chloride an inlet water pressure of 30...

Страница 20: ...g Clip 1 3 H4628 Elbow 3 8 Liquifit 1 4 V3163 0 ring 019 1 5 V3165 01 WS1 RFC Retainer Asy 0 5 gpm 1 6 V3182 WS1 RFC 7 V4144 01 Elbow 3 8 Liquifit Asy w RFC Not Shown V3552 WS1 Brine Elbow Asy w RFC Option Not Shown H4650 Elbow 1 2 with nut and insert Option Assembly includes V3182 WS1 0 5 gpm RFC Proper RFC Orientation Directs Refill Water Flow Towards The Washer Face With A Radiused I D Edge And...

Страница 21: ...3162 022 WS1 DLFC 2 2 gpm for 3 4 V3162 027 WS1 DLFC 2 7 gpm for 3 4 V3162 032 WS1 DLFC 3 2 gpm for 3 4 V3162 042 WS1 DLFC 4 2 gpm for 3 4 V3162 053 WS1 DLFC 5 3 gpm for 3 4 V3162 065 WS1 DLFC 6 5 gpm for 3 4 V3162 075 WS1 DLFC 7 5 gpm for 3 4 V3162 090 WS1 DLFC 9 0 gpm for 3 4 V3162 100 WS1 DLFC 10 0 gpm for 3 4 4 and 6 can be ordered as a complete assembly V4057 WS1 DRN ELBOW RETAIN W SIL ASY or...

Страница 22: ...90 090 9 0 34 1 1 V3190 100 100 10 0 37 9 1 V3190 110 110 11 41 6 1 V3190 130 130 13 49 2 1 V3190 150 150 15 56 8 1 V3190 170 170 17 64 3 1 V3190 200 200 20 75 7 1 V3190 250 250 25 94 6 The drain line flow control and fi tting are located on the side of the control valve and replaceable without the use of special tools The drain line flow control can be installed in the standard 3 4 drain line elb...

Страница 23: ...ty 1 V3151 WS1 Nut 1 QC 1 2 V4173 DV Meter Asy JST 1 3 V3118 01 WS1 Turbine ASY 1 4 V3105 O ring 215 1 5 V3003 01 WS1 Meter Plug ASY 1 6 V3013 Mixing Valve Option Order number V4173 includes V3118 01 WS1 Turbine ASY and V3105 O ring 215 THIS WATER METER SHOULD NOT BE USED AS THE PRIMARY MONITORING DEVICE FOR CRITICAL OR HEALTH EFFECT APPLICATIONS ...

Страница 24: ...1 NUT 1 QUICK CONNECT 2 2 V3150 WS1 SPLIT RING 2 3 V3105 O RING 215 2 4 V3189 WS1 FITTING 3 4 1 PVC SOLVENT 90 2 Order No V3007 02LF Description WS1 Fitting 1 Brass Sweat Assembly LF Draw ing No Order No Description Quan tity 1 V3151 WS1 NUT 1 QUICK CONNECT 2 2 V3150 WS1 SPLIT RING 2 3 V3105 O RING 215 2 4 V3188 LF WS1 FITTING 1 BRASS SWEATASSEMBLY LF 2 DO NOT INSTALL IN CALIFORNIA Order No V3007 ...

Страница 25: ...n tity 1 V3151 WS1 NUT 1 QUICK CONNECT 2 2 V3150 WS1 SPLIT RING 2 3 V3105 O RING 215 2 4 V3317 WS1 FITTING 1 1 4 PLASTIC MALE NPT 2 Order No V3007 06 Description WS1 Fitting 1 Plastic Male BSPT Assembly Draw ing No Order No Description Quan tity 1 V3151 WS1 NUT 1 QUICK CONNECT 2 2 V3150 WS1 SPLIT RING 2 3 V3105 O RING 215 2 4 V3316 WS1 FITTING 1 PLASTIC MALE BSPT 2 Order No V3007 07 Description WS...

Страница 26: ...Quan tity 1 V3151 WS1 NUT 1 QUICK CONNECT 2 2 V3150 WS1 SPLIT RING 2 3 V3105 O RING 215 2 4 V3375 LF WS1 FITTING 1 1 4 1 1 2 BRASS SWEAT LF 2 Order No V3007 12LF Description WS1 Fitting 3 4 Brass SharkBite Assembly LF Draw ing No Order No Description Quan tity 1 V3151 WS1 NUT 1 QUICK CONNECT 2 2 V3150 WS1 SPLIT RING 2 3 V3105 O RING 215 2 4 V3628 LF WS1 FTG 3 4 BRASS SHARKBITE LF 2 Order No V3007 ...

Страница 27: ...er No Description Quan tity 1 V3151 WS1 NUT 1 QUICK CONNECT 2 2 V3150 WS1 SPLIT RING 2 3 V3105 O RING 215 2 4 V3790 WS1 ELBOW 3 4 QC W STEM 2 Order No V3007 16 Description WS1 Fitting 1 PVC Male BSPT Elbow Assembly Draw ing No Order No Description Quan tity 1 V3151 WS1 NUT 1 QUICK CONNECT 2 2 V3150 WS1 SPLIT RING 2 3 V3105 O RING 215 2 4 V3797 WS1 FTG 1 PVC MALE BSPT ELBOW 2 Order No V3007 17 Desc...

Страница 28: ...V3145 WS1 Bypass 1 Rotor 2 5 V3146 WS1 Bypass Cap 2 6 V3147 WS1 Bypass Handle 2 7 V3148 WS1 Bypass Rotor Seal Retainer 2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 Not Shown Order No V3191 01 Description WS1 Bypass Vertical Adapter Assembly Order No Description Quan tity V3151 WS1 Nut 1 Quick Connect 2 V3150 WS1 Split Ring 2 V3105 O Ring 215 2 V3191 WS1 Bypass Vertical Adapter...

Страница 29: ... water supply water supply water supply water supply water supply water supply water to top of tank supply water to distributor supply water and regenerant to top of tank supply water to top of tank supply water to top of tank supply water and regenerant to top of tank regenerant is siphoned in conditioned water from distributor rinse water to drain conditioned water to regenerant tank regenerant ...

Страница 30: ...RVICE MANUAL 22 SERVICE SPANNER WRENCH Order No V3193 02 Service Spanner Wrench Although no tools are necessary to assemble or disassemble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly ...

Страница 31: ...ы 36 6 Параметры настройки 37 7 Меню пользователя 38 8 Настройка времени 39 9 Режим программирования настройки работы системы 40 10 Режим программирования настройки инсталлятора 42 11 Меню диагностики 43 12 Гидравлический узел 45 13 Электромеханический узел 46 14 Инжекционный узел 47 15 Регенерационный узел 48 16 Дренажный узел 49 17 Водомерный узел 50 18 Байпасный вентиль 51 19 Комплект подключен...

Страница 32: ... противоточная Счетчик точность расходомер диапазон 5 0 95 42 л мин 0 02 5700 м Размеры Центральная труба Слив Рассольная линия Диаметр горловины корпуса фильтра Высота от горловины корпуса фильтра 1 2 130мм Масса 1 6 кг Электропитание Входящее 230 АС 50 Гц Исходящее 12 DC 500 мA Применение к корпусам фильтров диаметр умягчителей диаметр 6 12 6 12 Продолжительность стадий регенерации 1 Взрыхление ...

Страница 33: ...выполнен из пластика корпус клапана из стекло наполненного пластика диски клапана из износоустойчивой керамики Клапаны Ecosoft устойчивы к воздействию большого числа реагентов используемых для регенерации и очистки воды Конструкция клапанов оптимизирована для работы с высокой производительностью как в режиме сервиса так и в режиме промывки Процедура регенерации может быть начата по объему после оч...

Страница 34: ...на электронной плате подождите примерно 3 секунды и снова включите Данная процедура позволит клапану найти правильное сервисное положение после разборки Все трубопроводы должны подключаться в соответствии с местными нормами и правилами Размер дренажной линии должен быть не менее а при скорости обратной промывки превышающие 26 5 л мин или длиной свыше 6 0м необходимо подключать трубопроводом диамет...

Страница 35: ...оляет измененить значения программируемого параметра ДАЛЕЕ Нажатие кнопки ДАЛЕЕ позволяет 1 Осуществить переход между шагами программирования 2 Настроить текущее время Удерживайте в течение 3 секунд чтобы изменить время суток в меню настроек времени суток РЕГЕНЕРАЦИЯ Нажатие кнопки РЕГЕНЕРАЦИЯ позволяет 1 При разовом нажатии инициирует отложенную принудительную регенерацию в установленное время ре...

Страница 36: ...ьзуется условие регенерации RES и установлен фильтроцикл в килограммах СaCO3 будет автоматически высчитываться резервный ресурс Если задан фильтроцикл в м резервный ресурс не высчитывается Клапан управления может быть настроен на немедленную или отложенную регенерацию в указанное время суток Шаг 3S Доступно три режима 1 DELY регенерация произойдет в установленное время суток 2 On 0 регенерация про...

Страница 37: ...дения заданного количества воды Soft Delayed OFF 1 28 дней Регенерация произойдет в установленное время через заданное количество дней между регенерациями Soft On 0 02 5700 м3 1 28 дней Регенерация произойдет немедленно после прохождения заданного количество воды или через установленное количество дней в зависимости от того какое условие наступило первым Soft On 0 02 5700 м3 OFF Регенерация произо...

Страница 38: ... литри в минуту Индикатор скорости потока будет мигать при потоке воды Коды ошибок диагностируемые контроллером Код Причина ошибки 101 Проблема с двигателем 102 Остановка двигателя не правильное положение 103 Двигатель работает долго не удается найти правильное положение 104 Клапан не находит правильное положение На дисплее отображается OFF когда программирование ЗАБЛОКИРОВАНО На дисплее отображае...

Страница 39: ...и удерживайте кнопку ДАЛЕЕ пока не появиться индикатор SET и часы не начнут мигать Используйте кнопки ВВЕРХ или ВНИЗ чтобы установить часы Нажмите ДАЛЕЕ чтобы перейти к настройке минут Используйте кнопки ВВЕРХ или ВНИЗ для установки минут Нажмите ДАЛЕЕ чтобы вернуться на уровень пользователя дисплея RETURN TO NORMAL MODE ...

Страница 40: ... установите фильтроцикл системы в килограммах СаСО3 Этот шаг доступен если в шаге 3S установлено значение RES Если в шаге 3S выбрано DELY или On 0 тогда фильтроцикл необходимо ввести в м от 0 02м 5700м или ВЫКЛ Нажмите ДАЛЕЕ чтобы перейти к шагу 5S Нажмите РЕГЕНЕРАЦИЯ что бы вернуться к предыдущему шагу STEP 1S STEP 2S STEP 3S STEP 4S STEP 5S STEP 6S STE STE STE STE STE RETURN TO NORMAL MODE STEP ...

Страница 41: ...ите время второй обратной промывки от 1 до 95 минут Этот шаг не появится если в шаге 2S установлено значение FLT1 Нажмите ДАЛЕЕ чтобы перейти к шагу 10S Нажмите РЕГЕНЕРАЦИЯ чтобы вернуться к предыдущему шагу STEP 7S STEP 8S STEP 9S STEP 10S STEP 11S RETURN TO NORMAL MODE STEP 10S ШАГ 10S Кнопками ВВЕРХ или ВНИЗ установите время прямой промывки от 1 до 95 минут или отключите выбрав OFF Нажмите ДАЛЕ...

Страница 42: ...Нажмите ДАЛЕЕ чтобы перейти к шагу 4I Нажмите РЕГЕНЕРАЦИЯ чтобы вернуться к предыдущему шагу STEP 4I ШАГ 4I Кнопками ВВЕРХ или ВНИЗ установите дни между регенерациями Нажмите NEXT чтобы перейти к шагу 5I Нажмите REGEN чтобы вернуться к предыдущему шагу STEP 5I ШАГ 5I Кнопками ВВЕРХ или ВНИЗ установите часы регенерации Время по умолчанию 2 00 ночи Если в шаге 3S была выбрана установка немедленой ре...

Страница 43: ...вернуться к предыдущему шагу STEP 4D ШАГ 4D Объем воды oчищенной через систему с момента последней регенерации Нажмите ДАЛЕЕ чтобы перейти к шагу 5D Нажмите РЕГЕНЕРАЦИЯ чтобы вернуться к предыдущему шагу STEP 5D ШАГ 5D Резервный ресурс Этот шаг отображается только если в шаге 3S была выполнена установка фильтроцикла системы Нажмите ДАЛЕЕ для перехода к шагу 6D Нажмите РЕГЕНЕРАЦИЯ чтобы вернуться к...

Страница 44: ... к шагу 10D Нажмите РЕГЕНЕРАЦИЯ чтобы вернуться к предыдущему шагу STEP 10D ШАГ 10D Измерение тока двигателя в момент перехода клапана из режима регенерации Измерения происходят при каждой 5 й регенерации Сохраняется до 99 измерений Нажмите ДАЛЕЕ чтобы перейти к шагу 11D Нажмите РЕГЕНЕРАЦИЯ чтобы вернуться к предыдущему шагу STEP 11D ШАГ 11D Кнопками ВВЕРХ или ВНИЗ можно посмотреть последние 10 ош...

Страница 45: ...V4106 Крышка привода диска ДК 1 7 V4110 Ось привода ДК 1 8 V4125 Пружинная подставка ДК 1 9 V4135 Компрессионная поставка ДК 1 10 V4108 О ринг 235 1 11 V4107 01 Основная крышка 1 12 V4111 Кольцо блокировки 1 13 V4114 Задняя панель 1 14 V4152 Крышка инжектора 2 15 V4196 О ринг 124 2 16 V3010 XX WS1 Инжектор 1 17 V4121 1Z Инжектор заглушка 1 18 V4120 Сетка инжектора 1 19 V4144 01 Реагентный узел с о...

Страница 46: ...я шестерня 9х48 ДК 1 3 V4116 Колесо энкодера ДК 1 4 V4012 Ось главной шестерни 1 5 V4117 Ось редукционной шестерни 3 6 V4195 Редукционные шестерни 12х48 3 7 V4133 01 Двигатель ДК 1 8 V3113 WS1 Пружинная клипса двигателя 1 9 V4123PI 01BOARD Плата ДК 1 10 V4128 Датчик положення правый ДК 1 11 V4127 Датчик положения левый ДК 1 12 V4118 Панель клапана ДК 1 13 V4119 01W Лицевая панель белая 1 ...

Страница 47: ...нжектор D красный V3010 1E WS1 инжектор E белый V3010 1F WS1 инжектор F синий V3010 1G WS1 инжектор G желтый V3010 1H WS1 инжектор H зеленый V3010 1I WS1 инжектор I оранжевый V3010 1J WS1 инжектор J светло синий V3010 1K WS1 инжектор K светло зеленый Не показано V3170 О ринг 011 Не показано V3171 О ринг 013 Инжектор и инжектор заглушка включают О ринг 011 нижний О ринг 013 верхний При противоточно...

Страница 48: ... 1 2 H4615 Клипса 1 3 H4628 Быстросъемный уголок 3 8 1 4 V3163 О ринг 019 1 5 V3165 01 WS1 Фиксатор RFC 1 6 V3182 WS1 RFC реагентный ограничитель 7 V4144 01 Быстросъемный уголок 3 8 в сборе Не показано V3552 WS1 солевой узел в сборе Опционально Не показано H4650 Уголок с гайкой и вставкой Опционально Необходимый RFC вставить заокругленной стороной к потоку воды Поток воды ...

Страница 49: ...л мин для уголка V3162 010 WS1 DLFC 3 8 л мин для уголка V3162 013 WS1 DLFC 4 9 л мин для уголка V3162 017 WS1 DLFC 6 4 л мин для уголка V3162 022 WS1 DLFC 8 3 л мин для уголка V3162 027 WS1 DLFC 10 2 л мин для уголка V3162 032 WS1 DLFC 12 1 л мин для уголка V3162 042 WS1 DLFC 15 9 л мин для уголка V3162 053 WS1 DLFC 20 1 л мин для уголка V3162 065 WS1 DLFC 24 6 л мин для уголка V3162 075 WS1 DLFC...

Страница 50: ...ЮЩЕГО КЛАПАНА ДЛЯ СИСТЕМ ОЧИСТКИ ВОДЫ 50 17 ВОДОМЕРНЫЙ УЗЕЛ No Код Наименование Кол 1 V3151 WS1 Гайка 1 2 V4173 Счетчик ДК 1 3 V3118 01 Крыльчатка 1 4 V3105 О ринг 215 1 5 V3003 01 WS1 Заглушка счетчика 1 Не показано V3013 Клапан подмеса Опционально ...

Страница 51: ...1 Крышка байпаса 2 6 V3147 WS1 Ручка бай паса 2 7 V3148 WS1 Уплотнители ротора байпаса 2 8 V3152 О ринг 135 2 9 V3155 О ринг 112 2 10 V3156 О ринг 214 2 19 КОМПЛЕКТ ПОДКЛЮЧЕНИЙ No Код Наименование Кол 1 V3151 WS1 Гайка 1 2 V3150 WS1 Кольцо фиксатор 1 3 V3105 О ринг 215 1 4 V3316 WS1 Прямое подключение 1 ВSPT 2 No Код Наименование Кол 1 V3151 WS1 Гайка 1 2 V3150 WS1 Кольцо фиксатор 1 3 V3105 О ринг...

Страница 52: ... верхнюю часть фильтра исходная вода исходная вода исходная вода и регенерационный раствор в верхнюю часть фильтра исходная вода и регенерационный раствор в верхнюю часть фильтра исходная вода в верхнюю часть фильтра исходная вода в верхнюю часть фильтра подсос регенерационного раствора подсос регенерационного раствора очищенная вода из дистрибьютора очищенная вода из дистрибьютора исходная вода в...

Страница 53: ...ДЫ РУС 22 КЛЮЧ ДЛЯ СЕРВИСНОГО ОБСЛУЖИВАНИЯ Для удобства сборки и разборки клапана рекомендуется использовать специальный сервисный ключ Положения сервисного ключа при выполнении сервисных работ показано на чертеже Сервисный ключ является опциональным оборудованием приобретается отдельно ...

Страница 54: ... дефекты о которых не было сообщено в течение гарантийного срока или они были вызваны небрежным и или неправильным обращением а также на дефекты вызванные механическими повреждениями воздействием огня стихийных бедствий замерзанием вод попаданием горячей воды и другими подобными явлениями Ни при каких условиях ООО НПО ЭКОСОФТ не несет ответственности за какую либо порчу имущества либо любой другой...

Страница 55: ......

Страница 56: ...ecosoft com ...

Отзывы: