15
The system is
connected to water
supply using flexible
hose or small size pipe
Set up proper connection to
water supply pipe. Avoid long
runs of small size pipe
Clogged pre-filter
cartridge
Check the filter cartridge and
replace if necessary
Other
Contact your
dealer’s product
support
High
permeate
conductivity
Water temperature is
higher than allowed
Test temperature of feed water
and check that it conforms with
requirements in chapter 2
System is not operating
with proper
concentrate pressure
and flow rate
Write down readings on
pressure gauges and rotameters
and contact your dealer’s
product support
Water quality does not
meet requirements
Check that the water analysis
conforms with requirements in
chapter 2
Damaged brine seal or
membrane adapter
O-ring
Contact your dealer’s product
support
Fouled or damaged
membranes
Replace or chemical clean the
membrane
Other
Contact
your dealer’s product
support
Low permeate
flow rate
Water temperature is
lower than allowed
Test temperature of feed water
and check that it conforms with
requirements in chapter 2
System is not operating
with proper
concentrate pressure
and flow rate
Write down readings on
pressure gauges and rotameters
and contact your dealer’s
product support
Clogged membranes
due to fouling or
scaling
Carry out chemical cleaning,
contact y
our dealer’s product
support if membranes get
fouled too often
Other
Conta
ct your dealer’s product
support