background image

Owners Manual 

Models: 

200-USRO, 200-USRO-P 

REVISION # 

1.2 

REVISION DATE 

March 5, 2015 

US Water Systems 

Corporate Office 

1209 Country Club Road 
Indianapolis, IN 46234 

American Revolution 5-Stage RO System 

The only RO System on the market that is totally American-Made! 

Visit us online at  

www.uswatersystems.com

 

Содержание 200-USRO

Страница 1: ...1 2 REVISION DATE March 5 2015 US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 American Revolution 5 Stage RO System The only RO System on the market that is totally American Made Visit us online at www uswatersystems com ...

Страница 2: ...MEMBRANE POST CARBON PRE SEDIMENT PRE CARBON FAUCET AND MOUNTING KIT FILTER WRENCH DRAIN SADDLE FEED WATER ANGLE STOP TANK VALVE FAUCET CONNECTOR TUBING ...

Страница 3: ...nk and distribution system This pump is operated by the drain water The permeate pump will dramatically increase the faucet pressure A permeate pump system will not have an ASO valve The dedicated FAUCET is used to dispense RO produced water when needed FEED WATER ANGLE STOP VALVE is connected to the cold water line to supply water to the R O system WASTE WATER SADDLE VALVE is connected to the dra...

Страница 4: ...cally or horizontally There will be residual water spilled during the installation Make sure you have a pan and paper towels to catch and dry the area UNIT PREPARATION Open the shipping carton remove components and check that all parts are present Check empty storage tank to be sure air pressure is approximately 7 PSI Adjust if necessary This is typically factory set but it is a good idea to check...

Страница 5: ... Install the rubber washer on the faucet 3 Install the plastic sleeve on the threaded rod 4 Install the brass washer on the threaded rod 5 Install the brass nut on the threaded rod 6 Install the faucet in the sink and slide the plastic U washer on the bottom of the sink on the faucet 7 Tighten the nut on the faucet Be sure the plastic sleeve is in the correct position for the drain line barb conne...

Страница 6: ... tube into the faucet connector Leave the other end of the blue tube unconnected for now it will be connected later in the installation 10 If the air gap portion of the faucet is being used continue to the next steps Push the 1 4 drain line from the RO module on to the smaller brass barb on the bottom of the faucet Be sure the tube is completely pushed on the barb or a leak could occur 10 Now push...

Страница 7: ...ply valve for the sink faucet Open the sink faucet cold water and relieve the pressure Remove the sink faucet whip hose or tubing from the shutoff valve There will be residual water spilled when this tube is removed Be sure to have a towel to dry the water that is spilled 2 Now install the gasket bushing in the angle stop valve tee 3 Install the tee on the sink faucet shutoff valve and tighten it ...

Страница 8: ... in the tee 6 Push the orange supply tubing in the angle stop valve and install the lock clip Leave the other end of this tubing unconnected for now it will be connected later in the installation 7 Be sure the dark gray handle on the angle stop valve is in the closed position Now open the sink shutoff valve and check the angle stop connections for leaks If there are leaks repair them now ...

Страница 9: ...tlet of a garbage disposal or plugging of the RO drain line may result Procedures 1 Remove the circle shaped knockout from the gasket 2 Remove the backing paper and install the gasket on the port side portion of the drain saddle Be sure the gasket hole is lined up with the port hole 3 Position the port side of the drain saddle valve at selected location and mark for the opening Never position the ...

Страница 10: ...ot over tighten and make sure there is equal space between saddle halves on each side when fully tightened 7 If the air gap portion of the faucet is being used install the 3 8 black tubing from the faucet to the saddle valve and install the clip BE SURE THERE IS A STRAIGHT DROP FROM THE FAUCET TO THE DRAIN SADDLE A SAG IN THIS TUBING WILL CAUSE A DRAIN WATER BACKUP 8 If the air gap portion of the ...

Страница 11: ...eck add or release as required F Initial tubing connections It may be desirable to leave the access tubing when making the final connections This will allow space to pull the unit out of the cabinet for filter changes without disconnecting all the tubing If you want to secure the system and cut the tubing to fit that is fine but this may require that the system be removed for filter changes or the...

Страница 12: ...he carbon filter 5 Tighten the center sump hand tight and secure it with the supplied filter wrench by turning it an additional 1 4 1 2 turn 6 Remove the far left sump and install the carbon filter in the sump BE SURE that the rubber gasket is in place on BOTH sides of the carbon filter 7 Tighten the far left sump hand tight and secure it with the supplied filter wrench by turning it an additional...

Страница 13: ...e fitting with little effort Refer to connections instructions on Page 16 2 Use the supplied wrench to remove the membrane housing cap 3 Remove the membrane from the protective packaging and install it in the membrane housing There are two O rings on end of the middle membrane tube Lightly lubricate these O rings with the supplied silicone grease 4 BE SURE the membrane is fully seated in the housi...

Страница 14: ...ing screws and install screws allowing the mounting bracket slots to slip over them NOTE If the cabinet sidewalls are not solid unit may sit on the floor with screws to keep it against the cabinet in a vertical position The system doesn t have to be secured to the wall but it is a good practice If the system is not mounted to the cabinet wall and the tubing is not cut short the module and be remov...

Страница 15: ... inlet fitting Permeate Pump Installation If the system is equipped with a permeate pump clip the pump to the membrane housing using the supplied mounting bracket and make the connections to the pump using the label on the pump and the labels on the tubing There will be a Permeate IN Permeate OUT and Brine IN connection on the pump The Brine OUT connection will be made in the following step 4 Conn...

Страница 16: ...ot of water 5 If there are no leaks open the storage tank valve allow the system to fill Most systems will be full within 2 hours The system is full when the water to the drain stops Check for leaks with the system full and repair them accordingly NOTE When the system is first turned on water may intermittently spurt from the air gap opening on the side of air gap faucets This is common and should...

Страница 17: ...e top of the sump with a small amount of the silicone included Tighten the filter sump hand tight then using the wrench turn an additional turn but do not over tighten 7 The carbon block filter s are installed into the next sump for 3 4 Stage or the next two sumps for 5 Stage Lubricate the O ring at the top of the sump with a small amount of the silicone included Be sure the rubber gaskets are in ...

Страница 18: ...ank valve completely or a leak could occur 6 Allow the system to continue to operate until there is a steady stream coming from the faucet 7 Once there is a steady stream coming from the faucet close the faucet and open the tank valve Then go to the flushing procedure above NOTE If no objectionable tastes are noticed after second tank draining RO processed water is ready for use Otherwise drain ta...

Страница 19: ... day gpd or milliliters per minute ml min Using a graduated cylinder the formulas are REJECT RATIO The reject ratio is the amount of water produced compared to the amount of water flowing to drain The formula is as follows PERCENT RECOVERY The percent recovery is another way to measure the amount of water produced compared to the amount of water which is actually used The formula to determine perc...

Страница 20: ...hed fully into the tube stop 3 Push up to the tube stop Push the tube into the fitting to the tube stop The collet gripper has stainless steel teeth which hold the tube firmly in position while the O ring provides a permanent leak proof seal 4 Pull to check secure Pull on the tube to check that it is secure It is a good practice to test the system prior to leaving the site and or before use Discon...

Страница 21: ...Installation Instructions Residential Reverse Osmosis Drinking Water System Page 21 TO TANK Green Tube ...

Страница 22: ...tubing on the refrigerator ice maker or use the 7 16 x 3 8 water inlet solenoid adaptor If the solenoid adaptor is used remove the 1 4 existing line nut and sleeve then screw the adaptor to the water inlet solenoid No sealant or Teflon tape is required for solenoid adaptor It is a compression fitting Tighten the fitting and insert the 3 8 tubing Leave the ice maker off until the RO system is flush...

Страница 23: ...Installation Instructions Residential Reverse Osmosis Drinking Water System Page 23 ...

Страница 24: ...se Osmosis Membrane GENERAL PROVISIONS This warranty does not apply to any commercial or industrial installations or to any part of the reverse osmosis system which has been subjected to misuse neglect alteration or accident or to any damage caused by fire flood freezing Acts of God or any other casualty or if said system is damaged by anyone or if the original serial numbers have been removed Fou...