Program
Configuration settings are stored in non-volatile memory. Access
to each submenu is protected with passcode. To enter configuration
menu, hold
STOP for 8 seconds. In the menu, editing and storing
values is helped by flashing cursor.
START button moves cursor
one position to the right,
STOP button increments selected digit
by one, cycles between options, or scrolls to the next screen when
the cursor is at the '>' symbol.
Configuration menu layout is shown below.
MENU
Factory Setting
1.
SETTINGS
Settings and calibration passcode prompt
0000
1.
High pressure pump delay, s
10 sec
2.
Forward Flush 1 duration, s
60 sec
3.
Forward Flush 2 duration, s
0 sec
4.
High pressure pump power during Forward Flush 2, on/off
off
5.
Frequency of periodic Forward Flush in Service, h
4 hour
6.
Frequency of periodic Forward Flush in Standby, h
24 hour
7.
Read low feed pressure during Forward Flush, on/off
on
8.
Low feed pressure switch, NO/NC
NC
9.
Low feed pressure Fault delay, s
3 sec
10.
High feed pressure switch, NO/NC
NO
11.
Permeate backpressure switch, NO/NC
NC
12.
Backpressure Standby delay, s
1 sec
13.
Tank level switch, NO/NC
NC
14.
Tank level Standby delay, s
1 sec
15.
0…1000 μS/cm conductivity range, on/off
on
16.
0…50 μS/cm conductivity range, on/off
off
17.
Permeate conductivity Fault threshold, μS/c
m
0 uS/cm
18.
Permeate conductivity Fault delay, s
on
19.
Temperature probe, on/off
on
1.
Set permeate temperature, °C (if 1.19 is set to ‘off’)
2.
Display real temperature, on/off (if 1.19 is set to ‘on’)
1.21
New settings and calibration passcode