background image

Dendrometer Data Logger DL18 BLE

  

                                                                   

 

 

 

 

4) Raw Data conversion & Linear scaling 

 

Fig. 7: Linear scaling function 

 

On-logger linear data conversion: 

If configured as 

“Adapter Cable, Cable-2.5-Stereo (0-2.5 Volts DC)”, the raw measured 

data is in units of volts, ranging between 0 and 2.5 VDC. In case of a linear relationship 
between raw sensor output voltage and the parameter measured by the sensor, the linear 
scaling function can be configured to convert raw voltage signals directly on the logger 
(see Fig. 7). This is possible for all dendrometers except for the models DC3 and DC4, the 
air temperature and humidity sensor (T/RH-Sens), soil moisture sensor (EM 35), and light 
sensors (PAR: EM 20, Pyranometer: EM 25). The on-Logger linear scaling is configured 
via two value pairs (e.g. 0 VDC / X and 2.5 VDC / Y). The parameters X and Y are sensor 
dependent and in case of dendrometers X is always 0 (i.e. 0 VDC corresponds to 0 mi-
crometer), whereas Y differs depending on the dendrometer model the different Y factors 
are. 

 

Fig. 8  Enter linearization data 

For example for 11000 micrometer range sensors (e.g. DD-S2, DR3, DD-L1,

…) the cor-

rect configuration is: 0 VDC / 0 micrometers and 2.5 VDC / 11000 micrometers.  

Change the value in this field as follows.  Other 3 data fields remain unchanged.

 

  11,000.0000 for DR1, DR3, DD-L1, DD-S1, DD-S2, DRO, DRW, DDW, DC1, DV, DF1

 

  25,400.0000 for DC3, DD-L2, DR2, DF2 
  50,800.0000 for DC4, DD-L3, DF3 
150,000.0000 for DF4 

Содержание DL18 BLE

Страница 1: ...DL18 BLE Data Logger ECOMATIK GmbH Muenchner Str 23 D 85221 Dachau Germany Tel 49 8131 260 738 Fax 49 8131 260 736 e mail info ecomatik de website www ecomatik de User Manual Version 2022...

Страница 2: ...one year 2 Components After unpacking you should have following items 1 dendrometer logger with two AAA alkaline batteries already inserted 1 weather box for using the logger under outdoor conditions...

Страница 3: ...ve the rubber plug from the unused cable glands Fig 2 Connecting sensor cables to the logger 5 Installing the software The DL18 BLE can be conveniently configured and logged data read out via mobile d...

Страница 4: ...ogger DL18 BLE 3 2 Logger Status overview Data download Enter Configuration mode 3 Launch Logger Launch logger and configure Channel and Sensor Fig 4 Deployment information and Logger Setup Logging in...

Страница 5: ...Dendrometer Data Logger DL18 BLE 4 Fig 5 Logger Setup Stop mode and Logger channels list Fig 6 Sensor and Channel setup...

Страница 6: ...sensor T RH Sens soil moisture sensor EM 35 and light sensors PAR EM 20 Pyranometer EM 25 The on Logger linear scaling is configured via two value pairs e g 0 VDC X and 2 5 VDC Y The parameters X and...

Страница 7: ...x 4400 Dendrometer type DC3 DD L2 DR2 DF2 Micrometer raw data V x 10160 Dendrometer type DC4 DD L3 DF3 Micrometer raw data V x 20320 For Dendrometer type DF4 Micrometer raw data V x 60000 For other s...

Страница 8: ...terface Bluetooth Low Energy to Mobile devices or PC iOS 11 12 and 13 Android 7 8 9 and 10 Windows 10 Bluetooth 4 X and up Channel 4 for connecting up to 4 dendrometers Logging Interval 1 sec to 18 ho...

Отзывы: