Dendrometer Data Logger DL18

         

                                                                    

 

 

 

 
For Dendrometer types DR1, DR3, DD-L1, DD-S1, DD-S2, DRO, DRW, DDW, DC1, DV 

Micrometer = raw data (V) x 4400 

For Dendrometer types DF1, DC2 

Micrometer = raw data (V) x 6000 

For Dendrometer type DC3, DD-L2, DR2, DF2 

 Micrometer = raw data (V) x 10160 

For Dendrometer type DC4, DD-L3, DF3 

 Micrometer = raw data (V) x 20320 

 

For other sensor types, e.g. leaf temperature (LAT-B2), surface, tissue or soil temperature 
(T-Surface/-Tissue/-Soil), air temperature/humidity (T/RH-Sens) or soil moisture, raw sen-
sor signal will also be recorded in volts. Due to the complex conversion functions of these 
sensor  types,  raw  sensor  values  have  to  be  converted  manually  after  data  download  to 
your personal computer. For conversion, please use the conversion functions as given in 
the user

’s manual of the respective sensor (Excel programs for data conversion are avail-

able on request). 

 

Data conversion with the scaling function of the data logger 

The scaling function of the DL 18 can be used to automatically convert raw volt signals 
from dendrometer measurements into micrometers. For channels connected with other 
sensor types (LAT-B2, T-Surface/-Tissue/-Soil, T/RH-Sens, soil moisture), please do not 
use the scaling function. In those cases the raw sensor signals will be recorded in volts 
and have to be converted manually after data download.  

To enable the scaling function for dendrometers, click the scaling button (fig. 7, right side) 
and enter the following data in the 

table “

Linear Scaling Assistant

”. 

 

 

Change the value in this field as follows.  Other 3 data fields remain un-
changed.

 

11,000.00000  for  DR1, DR3, DD-L1, DD-S1, DD-S2, DRO, DRW, DDW, DC1, DV

 

15,000.00000  for  DF1, DC2

 

25,400.00000  for  DC3, DD-L2, DR2, DF2 
50,800.00000  for  DC4, DD-L3, DF3 

 

Fig. 8  Enter linearization data

 

Содержание DL 18

Страница 1: ...DL 18 Data Logger ECOMATIK GmbH Muenchner Str 23 D 85221 Dachau Germany Tel 49 8131 260 738 Fax 49 8131 260 736 e mail info ecomatik de website www ecomatik de User Manual Version 2019...

Страница 2: ...ers or other combinations of the above listed sensors The logger is powered by two user replaceable batteries With standard use the batteries will last more than one year 2 Components After unpacking...

Страница 3: ...ow temperature 4 Connecting dendrometers to the logger As the fig 3 shows you can connect up to 4 dendrometers to the logger It is very important to protect the logger against moisture Screw the cable...

Страница 4: ...r use Launching logger Connect the logger to USB port Click the Launch icon on the toolbar This displays the logger s Launch window looking similar to the following Fig 5 Launch window Launch Logger D...

Страница 5: ...ers without Scaling LCD units V Click Delayed Start for Lauching Logger 7 Data conversion The measured data with previous configuration fig 7 are in units of volts For dendrometers there are 2 ways to...

Страница 6: ...ual of the respective sensor Excel programs for data conversion are avail able on request Data conversion with the scaling function of the data logger The scaling function of the DL 18 can be used to...

Страница 7: ...Dendrometer types DC2 DF1 0 5 m for Dendrometer type DC3 DD L2 DR2 DF2 1 0 m for Dendrometer type DC4 DD L3 DF3 Accuracy 0 1 of reading Interface USB interface to PC Channel 4 for connecting up to 4 d...

Отзывы: