3.  Safety information and Maintenance  

For the functionality it is very important to protect the logger against moisture. Screw the 
cable gland firmly and replace the silica gel if necessary. In tropical regions the protection 
from moisture is particularly important. 

In normal use the battery lasts for more than a year. But remember, some batteries have 
poor quality. Therefore, it is useful to log the battery voltage. Check the battery indicator at 
data download. If you are planning a long measurement period under low temperature, 
you should use Lithium batteries instead of provided alkaline batteries. Lithium battery has 
much better properties at low temperature. 

4.  Connecting dendrometers to the logger  

As the fig. 3 shows, you can connect up to 4 dendrometers to the logger. 

It is very important to protect the logger against moisture. Screw the cable gland firmly, 
and never remove the rubber plug from the unused cable gland. 

 

 

 

 

 

 

 

 

 

 

Fig. 3 Connecting dendrometers to the logger 

 

5.  Installing the software 

To install the software from the USB Stick:  

Insert the stick in your computer, select the folder 

Ecomatik\software\windows\Hoboware_Free_Setup.exe for Windows computer  

or ecomatik\software\mac\Hoboware_Free_Installer.dmg for Mac computer 

  

6.  Configuring the logger 

The software has many features. For dendrometers you mainly need only 4 functions (fig. 
4): 

Lauch Logger

: Configure the logger. 

Data Readout

: Download measured data. 

Logger Status

: Shows what the logger is doing.  

Data Export

: Export data in CSV format for processing with Excel etc. 

Содержание DL 18

Страница 1: ...DL 18 Data Logger ECOMATIK GmbH Muenchner Str 23 D 85221 Dachau Germany Tel 49 8131 260 738 Fax 49 8131 260 736 e mail info ecomatik de website www ecomatik de User Manual Version 2019...

Страница 2: ...ers or other combinations of the above listed sensors The logger is powered by two user replaceable batteries With standard use the batteries will last more than one year 2 Components After unpacking...

Страница 3: ...ow temperature 4 Connecting dendrometers to the logger As the fig 3 shows you can connect up to 4 dendrometers to the logger It is very important to protect the logger against moisture Screw the cable...

Страница 4: ...r use Launching logger Connect the logger to USB port Click the Launch icon on the toolbar This displays the logger s Launch window looking similar to the following Fig 5 Launch window Launch Logger D...

Страница 5: ...ers without Scaling LCD units V Click Delayed Start for Lauching Logger 7 Data conversion The measured data with previous configuration fig 7 are in units of volts For dendrometers there are 2 ways to...

Страница 6: ...ual of the respective sensor Excel programs for data conversion are avail able on request Data conversion with the scaling function of the data logger The scaling function of the DL 18 can be used to...

Страница 7: ...Dendrometer types DC2 DF1 0 5 m for Dendrometer type DC3 DD L2 DR2 DF2 1 0 m for Dendrometer type DC4 DD L3 DF3 Accuracy 0 1 of reading Interface USB interface to PC Channel 4 for connecting up to 4 d...

Отзывы: