3
Model
EcoloxTech 240
Power
AC 110/220V 50/60HZ 180W
Dimensions
32 x 17 x 42 cm (12.5 x 6.5 x 16.5 in)
Weight
11.8 kg (26 lbs.)
Production Cell Type
Single cell electrolysis for generating hypochlorous acid (HOCl)
Concentration Range
20 to
20
0 ppm of free available chlorine (FAC)
Ampere Settings
13 to 22 amp
Pump Speed Settings
0 to 19 (max. speed to min. speed)
Ambient Temperature
5 to 50 °C (41 to 122 °F)
Feed Water & Brine Temperature
10 to 30 °C (50 to 86 °F)
Inflow Water & Brine
Water Quality
Hardness
less than
80 ppm
required. Hardness over 80 ppm
will damage electrolysis cells
.
Humidity
Less than 96% Relative Humidity (RH)
Minimum Flow Rate
1
L/min
Maximum Water Pressure
40 PSI
Specifications
Requirements