Control System
DryExx Basic
®
NOTE
The
DryExx Basic
®
control system is available exclusively with english display text.
6.1
Brief overview of configuration
The
DryExx Basic
®
permitts
the configuration of the following parameters for the
metering station in the menu item
“configuration generally
•
Number of packages per impulse of the optional meter
•
System pre pressuring time
Ensures that all circuits are supplied with the same output pressure for the
conveyor belt lubricant
•
System bleeding time
Ensures that there is no leakage on the nozzle fittings
•
Delay time for the empty detector unit
No error message during normal changing of a drum
•
Number of impulses for the optional oval wheel meter
•
Quantity of belt lubricant per impulse for the optional oval wheel meter
•
Nominal dosing value per circuit with positive and negative difference.
•
Configuration of the following parameters: for each lubrication circuit in the menu item
“configuration circuit ?”
(? = 1 to 8)
Impulse time for spraying
Pause time for spraying
•
the manual start of
one
impulse time by aborting the pause time for each lubrication
circuit separately in the menu item “booster”.
NOTE
All possibilities can be read off in plain language in the individual displays, please follow
the notes.
6.2
Visualisation (display views)
6.2.1 Basic Screen / Start Screen
NOTE
The Basic Screen / Start Screen is shown, if main power is switched on.
Fig. 6.1
The basic screen shows:
•
the status of the lubrication circuits
"pu“
= impulse time is active
"br"
= pause time is active
"bo"
= Booster with impulse time is inactive
•
current date and time of the system
•
Active alarms
This screen is only displayed when alarms are active:
To display the active alarm
Press button“
i
”
Содержание Lubo-DryExx -Basic
Страница 20: ...417101633_DryExx_Basic 20 Rev 6 02 15 11 Konformit tserkl rungen 11 1 Lub O Dry Exx Hardware...
Страница 21: ...417101633_DryExx_Basic 21 Rev 6 02 15 11 2 Lub O Dry Exx Steuerung DryExx Basic...
Страница 40: ...417101633_DryExx_Basic 40 Rev 6 02 15 11 Declarations of conformity 11 1 Lub O Dry Exx Hardware...
Страница 41: ...417101633_DryExx_Basic 41 Rev 6 02 15 11 2 Lub O Dry Exx Control System DryExx Basic...