Auxiliary DHW X
This is used to enable the auxiliary DHW system in both EMERGENCY and SUPPORT mode.
In EMERGENCY mode, the auxiliary system is activated automatically if there are any active
alarms that prevent compressor start-up.
In SUPPORT mode, the auxiliary system is activated after the compressor when the latter
cannot reach the target DHW storage tank temperature.
3.14.
POOL Menu
Pool
Used to enable the POOL mode.
In ecoGEO range, it can be used to adjust the percentage of minutes/hours that the heat
pump is dedicated to the POOL mode when there are simultaneous demands for heating
and pool during the WINTER program.
In ecoAIR and ecoGEO HP range, it can be used to adjust the setpoint temperature and the
start-up temperature differential of the pool.
The
icon indicates that there is a time schedule activated in the POOL mode.
Auxiliary pool X
This is used to enable the auxiliary POOL system in both EMERGENCY and SUPPORT mode.
In EMERGENCY mode, the auxiliary system is activated automatically if there are any active
alarms that prevent compressor start-up.
In SUPPORT mode, the auxiliary system is activated automatically for normal POOL
production, as programmed by the technical service.
3.15.
INFORMATION Menu
Press
for quick access to the information menu from the main screen.
Brine/Production
This shows the inlet and return temperatures, temperature difference, current pressure
and the percentage of circulator pump regulation in the brine and production circuits or
shows the simultaneous production valves regulation value.
Boiler
Shows whether the boiler is On or Off, the current temperature in the support with boiler
sensor and the regulation percentage of the boiler or the mixing valve.
Auxiliary DWH X
3:
Emergency:
Support:
User menu
/8
DHW/Legionella prot
Pool
Information
/8
Pool
Enable:
Winter program
Minutes per hour:
Pool
Enable:
emote control: OFF
SetT:
5
DTstart:
Auxiliary pool X
Emergency:
Support:
User menu
7/8
Pool
Information
Alarms
7/8
Brine/Production
Brine
Heat
Outlet:
35
Inlet:
5
99
DT:
3
5
Press:
4 bar
Pumps:
95
87
%
Boiler
State
Off
ealT:
4
egulation:
%