![Ecoflam MULTIFAM 500.1 PRE Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/ecoflam/multifam-500-1-pre/multifam-500-1-pre_manual_2354236026.webp)
26
www.ecoflamburners.com
EN
420010940500
STARTUP OIL SIDE
Adjusting the maximum oil flow rate
Put the selector on the maximum operation. Adjust the oil pressure reading the value on the return manometer / pressure gauge
according to the nozzle tables provided in the appendix.
NOTE:
the pump pressure is set from the factory at the pressure required nozzle pressure required as per table of nozzle selection in
appendix. If the output required is different from the one set from the factory the pressure can be adjusted according to the instruction
below.
Adjusting the pump pressure
The pump pressure is set at a value of 22-25 bar during the testing of burners.
Before starting the burner, bleed the air in the pump through the gauge port.
Fill the piping with heavy oil to facilitate the pump priming. Start the burner and check the pump feeding pressure.
In case the pump priming does not take place during the first pre-purging, with a consequent,
subsequent lock-out of the burner, rearm the burner’s lock-out to restart, by pushing the button on the control box.
If, after a successful pump priming, the burner locks-out after the prepurging,
due to a fuel pressure drop in the pump, rearm the burner’s lock-out to restart the burner.
Do never allow the pump working without oil for more than three minutes.
NOTE:
before starting the burner, check that the return pipe is open. An eventual obstruction could damage the pump sealing device.
SUNTEC TA....
1 - INLET
2 - RETURN
3 - BLEED AND PRESSURE GAUGE PORT
4 - VACUUM GAUGE PORT
5 - PRESSURE ADJUSTMENT
6 - TO NOZZLE
1
2
5
6
3
4
Servomotor SQM48 Air damper motor presetting
Air adjustment is accomplished through LMV parameters setting. Refer to LMV manual attacched.
Содержание MULTIFAM 500.1 PRE
Страница 33: ...33 www ecoflam burners com EN 420010940500 APPENDIX Fluidics nozzle chart...
Страница 34: ...34 www ecoflam burners com EN 420010940500 APPENDIX Fluidics nozzle chart...
Страница 35: ...35 www ecoflam burners com EN 420010940500 APPENDIX Fluidics nozzle chart...
Страница 40: ...40 www ecoflam burners com EN 420010940500 APPENDIX Electrical diagrams...
Страница 41: ...41 www ecoflam burners com EN 420010940500 APPENDIX Electrical diagrams...
Страница 43: ...43 www ecoflam burners com EN 420010940500...
Страница 47: ...47 www ecoflam burners com EN 420010940500...