7
Typical Installation Illustrations
FIG. 7
Drain
Fitting
Valve
Drain
Hose
Valve
Drain
Hose
1-1/2”
Air Gap
1-1/2”
Air Gap
1-1/2”
Air Gap
1-1/2” Air Gap
LAUNDRY
TUB
SUMP
STAND
PIPE
FLOOR
DRAIN
To standpipe, sump, laundry
tub or other suitable drain.
1/2” I.D.
(minimum)
copper tube
Push
in
for
Bypass
Clip
Drain Fitting
CONNECTING A RIGID VALVE DRAIN TUBE
To adapt a copper tube to the filter, buy a compression fitting (garden hose thread to
1/2” I.D. minimum tube and necessary tubing from your local hardware store.
Adaptor, garden hose
thread to compression
Pull
out
for
filtered water
“
Service”
FIG. 6
FIG. 5
INSTALLATION USING 3-VALVE BYPASS
MAIN WATER
PIPE
MAIN WATER
PIPE
INSTALLATION USING INCLUDED BYPASS VALVE
CROSS-OVER
Use if water supply flows from the left.
Include single or 3-valve bypass.
Filtered
Water
OUT
Unfiltered
Water
IN
Unfiltered Water
to Outside Faucets
120V,
60 Hz
Outlet
FILTERED
WATER
TO FILTER
INLET
UNFILTERED
WATER
FROM FILTER
OUTLET
BYPASS
Valve
OUTLET
Valve
INLET
Valve
1” NPT
Adaptor (2)
not included
Clip (2)*
O-Ring Seal (2)*
1” NPT Installation
Adaptor (2)*
Valve
INLET
For filtered water SERVICE:
-Open the inlet and outlet
valves
For unfiltered BYPASS:
-Close the inlet and outlet
valves
-Open the bypass valve
* Included with filter - Pipe and
fittings supplied by installer.
1” NPT
Adaptor (2)
not included
1” NPT Installation
Adaptor (2)*
Bypass Valve*
Clip (4)*
O-Ring Seal (2)*
Power
Supply