19

Position markers

(valve in service)

CAM

MOTOR

FIG. 36

Troubleshooting (continued)

MANUALLY INITIATED ELECTRONIC

DIAGNOSTICS

Use the following procedures to advance the filter

through the recharge cycles to check operation.
Remove the top cover faceplate assembly by unlock-

ing the tabs and lifting, to observe cam and switch

operation during valve rotation (See Figure 36).

1

. Press and hold for 3 seconds the SELECT button,

until one of the screens shown in Figure 35 is dis-

played.  If the valve is in service, fill, solution draw /

brining, backwash or fast rinse position (observe

markings on the valve cam), the display should

show “000 - -”, meaning the position switch is

open.  When the valve is moving, the display

should show “000 - P”, meaning that the position

switch is closed.

2

Only for filter systems modified by adding a

turbine and turbine cable:

   If a turbine has been installed in your filter’s valve

outlet port, the first 3 digits of the display in Figure

35 should count upward whenever water is flowing

through the system.

3

. Use the TOUCH/HOLD button to 

manually advance

the valve into each position and check correct switch

operation.

4

. While in this diagnostic screen, the following infor-

mation is available and may be beneficial for vari-

ous reasons.  This information is retained by the

computer from the first time electrical power is

applied to the electronic controller.

   

a

. Press the 

r

UP button to display the number of

days this electronic control has had electrical

power applied.

   

b

. Press the 

s

DOWN button to display the num-

ber of recharges initiated by this electronic con-

trol since the model code number was entered.

5

. Press the SELECT button and hold in for 3 sec-

onds until the model code shows in the display.

This code identifies the filter model.  If the wrong

number shows (see table on page 3), the filter will

operate on incorrect configuration data.

6

. To change the code number - Press the 

r

UP or

s

DOWN button until the correct code shows.

7

. To return to the present time display, press the

SELECT button.  

If the model code was

changed, make all timer settings.

NOTE:

If the electronic control is left in a diagnostic

display (or a flashing display when setting

times or hardness), present time automatically

returns if a button is not pressed within 4 min-

utes.

FIG. 35

Содержание HPF

Страница 1: ...NSAPFXLA tested and certified without media by the Water Quality Association under NSF ANSI Standard 61 for material safety requirements only and NSF ANSI Standard 372 for low lead content Not certif...

Страница 2: ...hold outlet that is in a dry location only grounded and properly protected by an overcurrent device such as circuit breaker or fuse This system is not intended to be used for treating water that is mi...

Страница 3: ...1 1 1 1 Filtering Micron Rating 20 Supply Water pH Limits 6 0 6 8 Capacity 34 000 gal 15 500 gal at 10 psi maximum pressure drop at 35 psi inlet pressure Valve inlet outlet and installation adaptors...

Страница 4: ...ts of tastes and odors and or higher water usages may shorten this time Activated carbon can t be regenerat ed and must be replaced when exhausted see page 16 WATER NEUTRALIZING FILTER All water when...

Страница 5: ...lled indoors Keep the filter out of direct sunlight The sun s heat may soften and distort plastic parts TOOLS PIPE FITTINGS OTHER MATERIALS YOU WILL NEED Plastic inlet and outlet fittings included wit...

Страница 6: ...sh the tank opening with water to clean media particles from the top of the tank Uncover the bottom distributor stand tube 11 Finish filling the tank with water up to the top of the tank IMPORTANT Be...

Страница 7: ...G 5 INSTALLATION USING 3 VALVE BYPASS MAIN WATER PIPE MAIN WATER PIPE INSTALLATION USING INCLUDED BYPASS VALVE CROSS OVER Use if water supply flows from the left Include single or 3 valve bypass Filte...

Страница 8: ...ring Clip Cross section of valve inlet or outlet Bypass valve or plastic adaptor Snap clips into place between larger diameter rings FIG 11 Turn the bypass valve downward if connecting to floor level...

Страница 9: ...ting the hose may cause a back pressure that could reduce backwash flow and proper mineral bed cleaning 6 FLUSH PIPES CIRCULATE DISINFEC TANT EXPEL AIR FROM FILTER AND TEST YOUR INSTALLATION FOR LEAKS...

Страница 10: ...to a 120V 60 Hz electrical outlet Be sure the outlet is always live so it can not be switched off by mistake Installation Instructions 8 PROGRAM THE TIMER See pages 11 12 for instructions to program t...

Страница 11: ...advance the display Hold the buttons down for fast advance 2 When the correct time is displayed press the SELECT button and the display will change to show the next setup screen 2 The default setting...

Страница 12: ...this time as the water heater will refill with unfiltered water FIG 19 VACATION CONTROL 1 Before going on vacation or other long absence press but do not hold the TOUCH HOLD button so that VAC begins...

Страница 13: ...Use the r UP or s DOWN buttons to adjust solu tion draw rinse time from 0 to 255 minutes 3 When the desired draw time is displayed press the SELECT button and the display will change to show the 12 24...

Страница 14: ...he table below explains the choices available for when the auxiliary output will be on dur ing various portions of the recharge cycle FIG 26 SELEC TION NAME AUXILIARY OUTPUT FUNCTION OFF Off Remains o...

Страница 15: ...is difficult to determine exactly when to add more mineral When you have had the filter for a period of time experience will tell you when to add more mineral You can use the instructions following s...

Страница 16: ...the filter from the instal lation adaptors or from the bypass valve Figure 8 page 8 5 Remove the two clamp retainers and two clamp sections that hold the valve to the tank Lift the valve assembly up a...

Страница 17: ...to check flow control See page 22 to check for correct assembly and orientation Backwash flow should be 5 gpm or higher Low water pressure at house faucets Well pump pressure switch set too low Adjust...

Страница 18: ...ronic Control Board PWA TO REMOVE AN ERROR CODE 1 Unplug the power supply 2 Correct the problem 3 Plug the power supply back in 4 Wait for at least 8 minutes while the timer operates the valve through...

Страница 19: ...D button to manually advance the valve into each position and check correct switch operation 4 While in this diagnostic screen the following infor mation is available and may be beneficial for vari ou...

Страница 20: ...Position Switch S SERVICE Valve Cam FIG 38 BR FILL F BRINE DRAW Position Switch Valve Cam FIG 39 Position Switch Valve Cam FIG 40 BW BACKWASH FAST RINSE Position Switch Valve Cam FIG 41 Position Switc...

Страница 21: ...ng 2 3 4 x 3 11 7088855 Top Distributor 12 7105047 Repl Bottom Distributor 13 7092202 Mineral Tank 10 x 47 7113074 Mineral Tank 12 x 54 14 7339141 Catalytic Carbon 1 cu ft Chloramine Chlorine Taste Od...

Страница 22: ...2 Valve Exploded View Wear Strip Seal Cross section View 52 50 53 54 55 51 56 57 58 59 60 61 66 67 78 62 63 64 68 69 65 77 70 83 72 70 71 72 73 74 75 76 79 80 81 82 84 Flow Plug Assembly Assembled Vie...

Страница 23: ...g Wave Washer 67 7185500 Rotor Disc Key No Part No Description 7342712 Drain Plug Kit 1 includes Key Nos 64 68 69 68 Plug Drain Seal 69 Spring 70 7089306 Clip 1 single 2 req 7336428 Clip 1 pack of 20...

Страница 24: ...orce of nature such as but not limited to freezing flood hurricane tornado or earthquake is not covered by this warranty In all such cases regular parts and serv ice charges will apply We assume no wa...

Отзывы: