11
Programming the Electronic Controller
CONTROLLER SETTINGS REQUIRED
upon installation, and after an extended power outage.
When the power supply is plugged into the electrical
outlet, a model code (see table on page 3) and a test
number (example: J3.8), are briefly shown in the dis-
play. Then the words “PRESENT TIME” appear and
12:00 PM begins to flash.
A. SET PRESENT TIME OF DAY
If the words “PRESENT TIME" do not show in the dis-
play, press the SELECT button several times until
they do.
FIG. 14
FIG. 15
B. SET DAYS BETWEEN RECHARGES
1
. If you completed the previous step, the word
“RECHARGE" should show in the display (See
Figure 16). Otherwise, press the SELECT button
several times until it does.
1
. Press the
r
UP or
s
DOWN buttons to set the
present time. Up moves the display ahead; down
sets the time back. Be sure AM or PM is correct.
NOTE:
Press buttons and quickly release to slowly
advance the display. Hold the buttons down
for fast advance.
2
. When the correct time is displayed, press the
SELECT button, and the display will change to
show the next setup screen.
2
. The default setting is 3 days. This means that the
filter will recharge every 3 days. To change the
number of days between recharges, use the
r
UP
or
s
DOWN buttons to adjust from 1 to 99 days.
FIG. 16
FIG. 13
UP button
DOWN
button
Display
TOUCH/HOLD
button
SELECT
button
Number of
People
Iron
(parts per million)
1 - 2
3 - 4
5 - 7
8 - 20
1
4 days 3 days 2 days
1 day
2
4 days 3 days 2 days
1 day
3
4 days 3 days
1 day
1 day
4
3 days 2 days
1 day
1 day
5
3 days 2 days
1 day
1 day
6
2 days
1 day
1 day
1 day
7
2 days
1 day
1 day
1 day
NOTE:
If the water supply has high turbidity (sand, silt, sedi-
ments, etc.) set to recharge more often than the table
shows. Carbon and neutralizing filters may only need
to backwash once a week, depending on application.
3
. When the desired number of days is displayed,
press the SELECT button, and the display will
change to show the next setup screen.