background image

 
 

  5 

 

Introduction 

MyVirtuoso  Home

 

is  the  complete  home  automation  system  for  energy 

savings  and  remote  control  of  your  property,  using  a  smartphone  or 
tablet.  It  enables  full  control  of  devices  using  the  same  Z-Wave  wireless 
protocol.  

Using  MyVirtuoso  Home,  you  can  manage  an  integrated  and 
comprehensive energy consumption.  

By implementing precise rules and using the various devices connected to 
the gateway, energy savings of up to 

30%

 can be achieved. 

The  user  can  enjoy  improvements  in  comfort  level,  while  at  the  same 
time, cost savings and environmental benefits can be achieved. 

One  key  advantage  of  the  system  is  that  the  various  mains  powered 
wireless  devices  act  as  signal  repeaters  for  the  other  devices  in  their 
range, so signals can bypass obstacles and the range is extended beyond 
the stated 30m (uninterrupted).  

Benefits include: 

 

Energy & cost savings through greater consumption control; 

 

Heating control for further cost savings & comfort; 

 

Automation of household devices & lighting; 

 

Securirty IP cameras; 

 

Wireless set-up - easy to install and retro-fit; 

 

Modular system – easy to expand over time; 

 

Remote access via smartphone or tablet; 

 

User friendly app. 

Содержание MyVirtuoso Home

Страница 1: ...User manual...

Страница 2: ...Connecting Mobile Device with Gateway 12 Connecting the Gateway to another router 13 Including or Excluding Devices 14 Devices for Heating Control 15 Thermostatic Radiator Heads 15 Comfort and Eco tem...

Страница 3: ...tion 44 Virtual device widget 46 Rules 48 When Function 49 IF Function 50 Then Function 50 Rule Options 51 Heating Control using a Wireless Thermostat including Boiler Radiators 54 Heating Control usi...

Страница 4: ...Connectivity notification repeat time 97 General notifications alarms 98 Notification using a motion sensor 98 Notification using a temperature sensor 104 General notification repeat time 112 Delete n...

Страница 5: ...vements in comfort level while at the same time cost savings and environmental benefits can be achieved One key advantage of the system is that the various mains powered wireless devices act as signal...

Страница 6: ...Do not use devices in gas filled environments 5 Do not place the gateway near heat sources 6 Only use original accessories provided by EcoDHOME SmartDHOME 7 Do not place cables and or power supplies...

Страница 7: ...his symbol must be disposed of through appropriate collection sites Improper disposal may have negative consequences for the environment and for human health The recycling of materials will help to co...

Страница 8: ...sed modifications or reconstructions not described in this manual are not permitted Battery Safety Precautions Do not burn disassemble or puncture Like other batteries of this type paired devices in c...

Страница 9: ...dentifying Parts of the Gateway Power Supply Status LED USB Ports Ethernet Port HDMI port Gateway MyVirtuoso Home ES Energy Saving USB Ports Ethernet Port Status LED Power Supply Gateway MyVirtuoso Ho...

Страница 10: ...c The gateway will try to update if there are any updates available We advise that you do not use the gateway for 60 minutes so that it can update without interruption ATTENTION Please do not unplug t...

Страница 11: ...11 Fig 1 d Now access the App and follow the Wizard for first connection and registration ATTENTION During the registration Wizard operation gateway must have access to the internet...

Страница 12: ...nd the gateway under a different network or 3G network NOTE Remote connection to the gateway is only possible after the first connection HOME mode required first time NOTE During the set up make sure...

Страница 13: ...our home router proceed as follows to restore the connection between the gateway and the MyVirtuoso Home App a Connect the gateway to the new router and connect your mobile device to its Wi Fi network...

Страница 14: ...extend the signals to more distant devices Z Wave technology provides a signal mesh capability so that signals are reached all over the property To add or remove a device you need to go through eithe...

Страница 15: ...vices with a single MyVirtuoso Home gateway NOTE To exclude devices follow the same procedure simply select Remove device from device settings menu rather than Add device Devices for Heating Control T...

Страница 16: ...16 Fig 4 NOTE the menu location may be different on some mobile devices b Select Add Device from Device Settings menu Fig 5...

Страница 17: ...e device automatically pairs on insertion of the batteries Insert one battery when prompted with above message add the second battery When successfully included the device appears on the app 2 Insert...

Страница 18: ...process specific information will be sent to the gateway this usually takes a matter of minutes If after inclusion the device does not appear on the list it means that device has not completed this co...

Страница 19: ...ude again NOTE If the device fails to include even after following all these steps contact technical support e To change the name of the device hold on its name and it opens a menu containing Change d...

Страница 20: ...t the temperature h Press again the radio button to save the set temperature Comfort and Eco temperatures a From the main screen select main menu then select Device Settings b Press and hold the name...

Страница 21: ...21 Fig 9 c Select Set Eco Comfort level Fig 10 d Un check Use default...

Страница 22: ...22 Fig 11 e Set required temperature and confirm with OK Fig 12 f At this point the temperatures you set will be used and applied by...

Страница 23: ...ll down to the global temperature settings Manual mode The manual mode allows the head to work with the On Off commands the TTDZ is completely opened the TTDZ is completely closed Follow this steps to...

Страница 24: ...24 Fig 13 c Select Manual mode and confirm with OK Fig 14...

Страница 25: ...cluded in your gateway a From the main page go to Settings b Select Gateway Settings c Scroll down to Valve temperature offset d Enter in the offset and confirm with OK e At this point the heads will...

Страница 26: ...he remaining single wire is the aerial wire to pick up the Z Wave signal If the actuator is housed in the boiler unit then arrange the aerial wire protruding outside of the metal casing of the boiler...

Страница 27: ...27 Fig 16 b Select Add Device from Device Settings menu Fig 17 c When prompted by Press the inclusion button of the device and...

Страница 28: ...28 wait press the button on the actuator three times rapidly to include the device Fig 18 d After some seconds the device should be included and displayed on the app...

Страница 29: ...g on off if you press the actuator button on the app which confirms it is functioning properly the actuator is ON the actuator is OFF f If pairing has not been successful then repeat inclusion process...

Страница 30: ...30 Fig 20 Temperature and Humidity Sensor The package leaflet gives instructions for pairing this device Pair in close proximity to the gateway Refer to manual for inclusion exclusi on operations...

Страница 31: ...three times in 1 5 seconds After some seconds the device should appear on the app Fig 21 The sensor should then be placed on the wall in a suitable place avoiding direct sunlight and close proximity t...

Страница 32: ...the device and wait press the inclusion button on the actuator three times rapidly to include After the message disappears press the refresh button on the app The app will then display the actuator ba...

Страница 33: ...hen prompted by Press the inclusion button of the device and wait press the inclusion button on the meter three times rapidly to include After the message disappears press the refresh button on the ap...

Страница 34: ...n of the gateway you can check real time production from a photovoltaic system the overall household consumption and use any available balance to power specific devices a Select Device Settings from m...

Страница 35: ...35 Fig 23 d Select PV Production Fig 24 e After selecting the production meter press the minus sign...

Страница 36: ...36 Fig 25 f Select the Household Consumption Fig 26...

Страница 37: ...37 g Press Done to save the virtual device Fig 27 h To check it has been created and saved scroll down the Devices list to find the virtual device Balance...

Страница 38: ...attery powered devices NOTE Press the icon to get the device battery status Battery powered devices are in sleep mode most of the time to conserve battery life Once included they communicate with the...

Страница 39: ...on is crossed check to see if device is powered or is too far away from the gateway Once powered or brought within range possibly with repeater press the icon to restore connectivity Within a few minu...

Страница 40: ...40 Fig 30 NOTE Other time periods can selected see figure Fig 31...

Страница 41: ...directly but through more than one path This is still considered to be a stable connection A yellow block is considered to be an unstable connection A red block does not indicate no connection at all...

Страница 42: ...will automatically update the routing table as devices choose other better ways to communicate with the gateway Update the network topology as follows a From the Homepage main menu select Settings b...

Страница 43: ...lable within Device Settings Mesh network One of the advantages of the Z Wave system is the mesh network the devices create Once included the devices independently create a network of wireless connect...

Страница 44: ...eases as devices are added and the mesh strengthens Widget configuration On the main screen of the application the default set up includes all classes of device weather and clock widgets To temporaril...

Страница 45: ...45 Fig 35 b Press on and then select the desired category of devices Fig 36...

Страница 46: ...nd associated functions are available with MyVirtuoso Home ES version only The Virtual Device Widget has the ability to store data on the consumption of the property Orange the photovoltaic production...

Страница 47: ...47 Fig 38 Fig 39 NOTE When the consumption in the home is greater than the...

Страница 48: ...m You can define one or more conditions which if met will trigger an automatic event For example you can turn on the heating system when the temperature in the home drops below a set threshold or adju...

Страница 49: ...When Function When is the period of activation for the rule If you do not select a period the Rule will be active 24 7 Below shows that the Rule will be active from Monday to Friday from 06 00 to 13...

Страница 50: ...n IF The condition set suggests that if the sensor detects door opening then the rule will trigger an event Fig 43 Then Function Then contains actions that are performed if the conditions in IF are sa...

Страница 51: ...site condition Activating this option generates the contrary rule to the one you are creating For example screenshot below shows that if the sensor detects door window sensor is open then the rule wil...

Страница 52: ...ons to be satisfied Screenshot below shows two devices and two conditions in the IF section Checking AND Condition for IF Devices means both conditions need to be satisfied to trigger an event In this...

Страница 53: ...into opposite state at schedule end This option refers to When and triggers the opposite state for devices after schedule ends For example Screenshot below shows that the Rule will be active Monday t...

Страница 54: ...set is 10 minutes this means that 10 minutes after the door is shut opposite to If condition the actuator will switch off opposite to Then condition Heating Control using a Wireless Thermostat includi...

Страница 55: ...55 Fig 49 b Select the symbol to start a new rule c Type the name of your new rule and select OK Fig 50...

Страница 56: ...56 d Press on and select When from the rule drop down menu Fig 51 e Check the required days of the week and type in or move dial the start and finish times for each time slot Fig 52...

Страница 57: ...n t appear press and hold on the empty calendar f Then press OK to display settings on calendar NOTE Time periods chosen will be saved when the rule itself is saved g Press on select If from the rule...

Страница 58: ...58 Fig 54 i Select the temperature option and enter the temperature below which you want the heating to switch on then OK Fig 55...

Страница 59: ...59 Fig 56 j Select and Then from the rule drop down menu Fig 57...

Страница 60: ...60 k Check the radiator valves and boiler actuator you want to control then OK Fig 58 l Select Comfort mode for heads and put the boiler button into the state...

Страница 61: ...le drop down menu n 1st and 3rd buttons should already be checked these switch off the boiler put heads into Eco when desired temperature is reached Opposite rule and after a heating period finishes P...

Страница 62: ...ttings NOTE To edit the time schedules open up the rule and press the calendar section Either add a new time slot in the way you entered up the original schedules or check the relevant box and select...

Страница 63: ...with OK To delete the rule a Press on to delete NOTE If you want to disable the rule use the On Off button in the rule list Heating Control using Digital Thermostatic Heads including Boiler Actuator T...

Страница 64: ...section to select the correct time zone UTC 00 00 and the Comfort Eco temperatures you require different temperatures can be set for each head c Select Rule Settings from the main Settings menu Fig 6...

Страница 65: ...65 Fig 63 b Select and then When from rule drop down menu Fig 64...

Страница 66: ...move dial the start and finish times for each time slot and then press OK Fig 65 NOTE If the Program definition window doesn t appear press and hold on the empty calendar NOTE Multiple time slots all...

Страница 67: ...67 Fig 66 e Check the digital heads then OK Fig 67...

Страница 68: ...rt mode temperature the grey area is Eco mode temperature Fig 68 g Press on to save the rule Rule 2 Sets heating to come on whenever one head is open a Select Rule Settings from the main Settings menu...

Страница 69: ...69 Fig 69 d Select and then If from rule drop down menu Fig 70...

Страница 70: ...70 e Check radiator valves then OK Fig 71 f Select Head state and status for each thermostatic head...

Страница 71: ...71 Fig 72 g Select and Then from rule drop down menu Fig 73...

Страница 72: ...72 h Check Heating Boiler Actuator then OK Fig 74 i Put Heating button into on position Fig 75...

Страница 73: ...in the off position Fig 76 l Return to rule screen and then on to save Rule 3 Sets heating to switch off when all heads are in closed position a Select Rule Settings from the main Settings menu b Sele...

Страница 74: ...74 Fig 77 d Select and then If from rule drop down menu Fig 78 e Check thermostatic heads then OK...

Страница 75: ...75 Fig 79 f Select Head state and status for each head Fig 80...

Страница 76: ...76 g Select and Then from rule drop down menu Fig 81 h Check the Boiler actuator then OK Fig 82...

Страница 77: ...77 i Select status for Heating Fig 83 j Select and then Rules option from rule drop down menu k Check And condition for IF devices...

Страница 78: ...78 Fig 84 NOTE Above setting means boiler remains on until all heads are closed l Return to rule screen and then on to save...

Страница 79: ...her add a new time slot in the way you entered up the original schedules or check the relevant box and select delete icon This can be repeated for any day simply select the required day and the saved...

Страница 80: ...ch actuator or smart socket chosen from the device list can be controlled in a similar fashion To control lighting or other devices according to saved times alone see Scenarios Lighting Control sectio...

Страница 81: ...81 Fig 87 d Select and then When from rule drop down menu Fig 88...

Страница 82: ...in or move dial the start and finish times for each time slot Fig 89 NOTE If the Program definition window doesn t appear press and hold on the empty calendar NOTE Multiple time slots allowed for each...

Страница 83: ...83 Fig 90 g Check boxes for device used to control lighting in this case the Light Sensor then OK could also use other sensors such as the motion or door window Fig 91...

Страница 84: ...84 h Press on the Light sensor name Fig 92 i Type in the Lux level below which you want the lights to switch on then OK Fig 93...

Страница 85: ...85 j Select and Then from rule drop down menu Fig 94 k Select devices you want to activate then OK Fig 95...

Страница 86: ...le options from the rule drop down menu n 1st and 3rd buttons should already be checked these switch off the lights when the desired lux level is reached Opposite rule and after a lighting period fini...

Страница 87: ...section Either add a new time slot in the way you entered up the original schedules or check the relevant box and select delete icon This can be repeated for any day simply select the required day and...

Страница 88: ...a scenario is that a scenario does not require the If one or more conditions to trigger an event as it is based on time schedules alone All devices paired to the gateway can be controlled using scena...

Страница 89: ...89 Fig 98 b Select the symbol to start a new rule c Type in the name of your new scenario then OK Fig 99...

Страница 90: ...then When from rule drop down menu Fig 100 NOTE The menu location may be different on some mobile devices e Check the required days of the week and type in or move dial the start and finish times for...

Страница 91: ...g 101 NOTE If the Program definition window doesn t appear press and hold on the empty calendar NOTE Multiple time slots allowed for each day f Then press on and select Add devices from scenario drop...

Страница 92: ...92 Fig 102 g Check boxes for device s to activate in this case the hall light then OK Fig 103...

Страница 93: ...93 h Put buttons into state Fig 104 i Press on and select Scenario options from the scenario drop down menu j Make sure the button is checked...

Страница 94: ...es open up the scenario and press the calender section Either add a new time slot in the way you entered up the original schedules or check the relevant box and select delete icon This can be repeated...

Страница 95: ...For example the gateway is able to send a notification at the time when a sensor detects an opening door a motion sensor detects movement or a smoke detector the presence of smoke In addition the gate...

Страница 96: ...included devices drops below the pre set level Battery level for notification Change the battery level for notification as follows a From the main menu go to Settings b Select Gateway Settings c Sele...

Страница 97: ...tion messages as often as the time interval you have set regardless of battery charge status Notifications for device connection state Notifications for the status of device accessability are always a...

Страница 98: ...the user using Rule settings MyVirtuoso Home will notify you when one or more conditions contained in a rule are satisfied Notification using a motion sensor This example shows how to set up a Notifi...

Страница 99: ...99 Fig 107 c Press and select When Fig 108...

Страница 100: ...100 d Set the required time e Press and select IF Fig 109 f Select the sensor and confirm with OK...

Страница 101: ...101 Fig 110 g Set the status of the motion sensor Fig 111...

Страница 102: ...Motion detected No motion detected h Press and select Then i Select Notify and confirm with OK Fig 112 j Check Send Push Notification and Priority if you want a notification highlit on the bulletin bo...

Страница 103: ...103 Fig 113 k Press and select Rule Options l Uncheck Activate opposite condition...

Страница 104: ...there is no movement detected m Go back a screen and press to save the notification Notification using a temperature sensor In the next example we will show you how to set up a notification with a tem...

Страница 105: ...his type of notification you must first pair a temperature sensor with your gateway a From the main menu go to Rule Settings b Press symbol and name your new rule in this case Low temperature alarm Fi...

Страница 106: ...106 Fig 116 d Set the required time e Press and select IF...

Страница 107: ...107 Fig 117 f Select the sensor and confirm with OK Fig 118...

Страница 108: ...108 g Press on temperature Fig 119 h Set the desired temperature and confirm with OK...

Страница 109: ...109 Fig 120 i Press and select Then j Select Notify and confirm with OK...

Страница 110: ...110 Fig 121 k Check Send Push Notification and Priority if you want a notification highlit on the bulletin board...

Страница 111: ...111 Fig 122 l Press and select Rule Options m Uncheck Activate opposite condition...

Страница 112: ...n is checked the gateway will notify when the temperature is above 15 C n Go back a screen and press to save the notification General notification repeat time To change the repeat time for this type o...

Страница 113: ...to delete notifications automatically To set the automatic delete time do the following a From the main screen go to Settings b Select Gateway Settings c Select Time of day messages delete and set th...

Страница 114: ...ype in and enter the Serial Number f Type in and enter the Security Key NOTE The activation keys mentioned above are shown on a card contained in the MyVirtuoso Home box g Confirm with OK h Once you a...

Страница 115: ...ld on the gateway name b Press on to delete Activate login You can enable a login facility to the application on your mobile device Follow these steps to create a login a From the main screen select S...

Страница 116: ...maximum number of users that can be connected to your router Webcams are not Z Wave devices so number you can set up with system are in addition to 25 device limit already mentioned Webcam search This...

Страница 117: ...17 a From the main screen select main menu then select Webcam Settings b Select Search for Webcams from webcam menu Fig 126 c After a brief search webcams found by the gateway will appear on the scree...

Страница 118: ...118 Fig 127 d Press and hold on the webcam name and then select Change Parameters Fig 128 e Enter the webcam details and then OK...

Страница 119: ...age Fig 129 Manual configuration If the automatic search did not detect any webcam you can configure your webcam using the manual mode To configure a webcam manually with MyVirtuoso Home proceed as fo...

Страница 120: ...120 Fig 130 d Press to return to the main screen e Select Security from the left hand menu then press the icon below to view the webcam streaming image...

Страница 121: ...webcam with MyVirtuoso Home you can add the widget to the main screen of the application To add a webcam widget proceed as follows a Select Widget Configuration from the main menu b Press on symbol c...

Страница 122: ...122 Fig 132 d Return to the main screen e After a brief loading period the Webcam Widget will appear on the main screen...

Страница 123: ...123 Fig 133 f Press on to display another webcam Fig 134...

Страница 124: ...ries some paired devices Gateway Dimensions 160 W x 120 D x 40 H Gateway Weight 334g Operating Temperature 0 40 C Fig 137 MyVirtuoso Home Protocol used by Sensors Actuators Z Wave Maximum number of Se...

Страница 125: ...125 www ecodhome co uk info ecodhome co uk Re Rev 08 2015 P P N 01335 0351 00...

Отзывы: