8.14
Smart-PV/Grid
You activate the smart grid function under parameter S01 (=1).
Smart-Grid
Operating status
Smart-Grid
EVU
Increased operation
ON
ON
OFF
ON
Normal operation
ON
OFF
Reduced operation
OFF
OFF
1
.
Smart grid and hot water mode are activated: The heat pump is primarily oper-
ated in hot water mode. The hot water temperature is changed to 70° C (hot
water tank temp.) < 69° C. The hot water tank heating is switched on (hot water
tank temp.)
≥
70 and the hot water tank heating is switched off.
2
.
Smart grid is deactivated and the EVU signal is activated: If the hot water mode is
set as valid and the mode is switched on, the heat pump is primarily operated in
hot water mode (hot water tank temp.) < P03-P02, the hot water tank heating is
switched on, (hot water tank temp.)
≥
P03+2, the hot water tank heating is
switched off.
3
.
Smart grid is activated and the utility signal is deactivated: The heat pump is
operated normally.
4
.
Smart Grid and hot water mode are deactivated: The appliance is not operated in
hot water mode and the hot water tank heating and the disinfection function are
inactive. The appliance switches off after the set switch-off time S02.
8.15
Pump function when temperature is reached
Once the switch-off temperature has been reached, the mode of operation can be
defined under the set value F02.
At 0, the pump stands for time-out F03 and switches on for 3 minutes. At 1, the pump
continues to run normally, at 2 it switches off until restart after the return temperature
falls below the set temperature.
8 Operating the heat pump
53
Installation Manual
Содержание EASYPELL EPA 09
Страница 1: ...Installation Manual Heat pump EASYPELL EPA 09 12 ENGLISH www easypell com 290108_EN...
Страница 27: ...7 7 Fitting the air separator EPA 09 1 4x 2 3 EPA 12 EPA12T 1 4x 2 3 7 Installation 27 Installation Manual...
Страница 30: ...Mainboard EPA 09 30 7 Installation Installation Manual...
Страница 32: ...Mainboard EPA 12 32 7 Installation Installation Manual...
Страница 34: ...Mainboard EPA 12T 34 7 Installation Installation Manual...
Страница 36: ...7 9 Removing the fan 36 7 Installation Installation Manual...
Страница 55: ...10 Power curves maximum Power curves EPA 09 10 Power curves maximum 55 Installation Manual...
Страница 56: ...Power curves EPA 12 56 10 Power curves maximum Installation Manual...
Страница 59: ...11 3 Hydraulic scheme 3 11 Hydraulic diagrams 59 Installation Manual...
Страница 62: ......
Страница 63: ......
Страница 64: ......