14/15
Montageanleitung / Assembly instruction / Notice de montage
ECO
SR BG III
ECO
SR BG III
ECO SR BG III
(DIN
rechts
/ DIN links spiegelbildlich)
(DIN
right
/ DIN left mirror image)
(DIN
droite
/ DIN gauche inverser l‘illustration)
Assembly for active leaves DIN right is described below. For active leaves DIN left, please proceed accordingly.
14
5b
6a-c
9
10
12
15
16
17
18
5a
5c
2
3+4
1a-c
7
8
13
19
Attach the drilling template and choose corresponding drill holes depending on mounting situation. Drill the holes.
Drill the hole pattern according to the drawing.
Insert the end caps into the active leaf slide rail (G) and into the passive leaf slide rail (S).
Insert the middle pieces into the active leaf slide rail (G) and into the passive leaf slide rail (S). The lugs on the middle pieces
have to point forwards and downwards!
1
3
2
1
2
Mounting with under-lintle angle
Direct mounting
Mounting with adaptor plate
Screw on the under-lintle angle (optional), shorten the active leaf profile if necessary. Screw on the door closer
mounting plates .
Screw on the adaptor plates (optional), shorten if necessary .Screw on the door closer mounting plates .
Screw on the door closer mounting plates.
Mount the active leaf slide rail and the passive leaf slide rail.
Fit the door closer.
The maximum opening angle of the door leaves is approx. 105°, depending on the constructional condition and the
door thickness. In order to avoid damages on doors and / or door closers, please set a door stopper at the
maximum opening angle (active and passive leaf).
1
2
Determine dimension
Ls
in line with drawing . Cut connecting rod to length in line with said dimension
Ls
+ 214 mm
and trim .
1
2
3
4
Push coupling sleeves as depicted onto the connecting rod . Turn the connecting rod by 90° .Push connecting rod between
the rod ends . Push the coupling sleeves over the rod ends and tighten grub screws . Attention: the screws of the coupling
sleeves have to point downwards.
2
Determine dimension
L
A
acc. to drawing . Cut the cover profile to dimension
L
A
- 6mm and deburr .
1
Attach the cover profile.
Functionality test SR
Open both doors approx. 60°, the active leaf has to remain open. The Passive leaf closes. The active leaf is only allowed to
close if the passive leaf reaches a closing angle of approx. 30°.
1
2
3
Attach the nylon clips . Clip on U-Cover and pinion cover .
Adjust the doorcloser as stated in the separate mounting instruction.
Move the triggering block until stop . Mount triggering angle at stop on the roll .
Important:
maximum projection length of
the door frame is 2mm, otherwise use distance plates
A
or
B
. The maximum projection length of the door frame with distance
plates is 8mm, all other lengths on request.
1
2
Open the valve for the closing speed and close the doors in the correct order .
1
1
1
2
2
2
Push the triggering block to its stop in direction of the door centre. Push the follower against the sliding block.
11
Open the inactive leaf . The shifting block will be moved by the sliding block . When the sliding block reaches the
reversal point where it will start moving into the opposite direction, the sliding block must be fixed with the pair of set screws .
1
2
a
b
After closing the valve for the closing speed,open the doors . Connect the arm to the sliding block .