How the Automatic Sediment Filter Works

Specifications

INSTALLATION LOCATION

To filter sediments from all household water, install the

Automatic Sediment Filter on the household’s main

incoming water pipe.  The Automatic Sediment Filter

Pressure

Tank

City Water Supply

Well Water Supply

Well

Pump

OR

Automatic

Sediment

Filter

Untreated Water to

Outside Faucets

Cold Water

to House

should be installed upstream from the water softener

(if any), the water heater and all inside faucets.  See

diagram below.

FIG. 3

Water

Softener

Water

Heater

Hot Water

to House

Planning the Installation

Service Flow Rate

35 gpm  (132 lpm)

Water Pressure Limits (minimum / maximum)

30 - 100 psi  (207 - 689 kPa)

Water Temperature Limits (minimum / maximum)

40 - 120 °F  (5 - 49 °C)

Inlet - Outlet Adaptors

1” NPT male threaded

The EcoPure Automatic Sediment Filter is designed to

be plumbed into a home’s incoming water supply pipe,

where it will capture particles of sediment from the

water and periodically flush them down the drain.

The unit has an electronic control that counts down the

days until the next automatic flush of collected sedi-

ment particles.  The number of days is programmable.
The electronic controller runs on a 9 volt battery.  The

controller will indicate when the battery needs to be

replaced.  An optional AC power adaptor (P/N

7302835) may also be purchased to eliminate the

need for batteries.
Three sizes of filter mesh are available. A 60 micron fil-

ter is included with the ASF unit, and optional 100 or

150 micron filters can also be purchased (see spare

parts list at the end of this manual).

NOTE:

This product is designed to reduce sand,

grit, debris, pipe scale and other loose matter.  On

water supplies that contain sticky sediment includ-

ing mud, silt and clay, you may have to remove

the sump and clean the screen periodically.

Содержание EP-ASF15

Страница 1: ...Friday 7 AM 6 PM CST or visit www ecopure com U S A www ecopure ca Canada When you call please be prepared to provide the model date code and serial number of your product found on the rating decal lo...

Страница 2: ...disposed of accord ing to Waste Electrical and Electronic Equipment WEEE requirements This directive or similar laws are in place nationally and can vary from region to region Please refer to your sta...

Страница 3: ...urther that the Automatic Sediment Filter is not damaged as the result of any unusu al force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure...

Страница 4: ...1 8 in 5 1 4 in 9V Battery Hose Clamp INSPECT SHIPMENT The Automatic Sediment Filter is shipped complete in one carton Remove all items from the shipping carton and check against the packing list bel...

Страница 5: ...ediment Filter is designed to be plumbed into a home s incoming water supply pipe where it will capture particles of sediment from the water and periodically flush them down the drain The unit has an...

Страница 6: ...s top cover and observe the IN and OUT markings Depending on the direction of water flow and the viewing angle the faceplate may need to be reversed turned around to face the opposite direc tion so t...

Страница 7: ...8 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment flush discharge water A floor drain close to the Automatic Sediment...

Страница 8: ...llowing before turning the water supply back on 1 Measure cut to needed length and connect the 3 8 in drain line provided to the Automatic Sediment Filter s valve drain fitting See Figure 8 on Page 7...

Страница 9: ...Parts List page for ordering information IMPORTANT Do not use any AC adaptor other than the EcoPure P N 7302835 with this Automatic Sediment Filter To install the optional AC adaptor 1 Remove the top...

Страница 10: ...in will start and stop several times 4 Once the sediment flush has been completed the 2 digit display will change to show the number of days until the next automatic flush or if the automatic flush fe...

Страница 11: ...increases the number of days by 1 When the number passes 30 it returns to zero indicated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic flush feature 4 When...

Страница 12: ...e water you saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF...

Страница 13: ...off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the main house water supply valve upstream from the Automatic Sediment Filter 3 Open a col...

Страница 14: ...Head Assembly 17 7300312 O Ring Sump 18 7298395 Sump 19 7300304 Drain Straw Key No Part No Description 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7298816 Filter Screen Assembly 100...

Отзывы: