background image

10

Programming the Electronic Controller

LED color State of LED

Shows when...

Green

Blinks every

8 sec.

Unit is in normal operation

Amber

On steadily

You are programming

the controller

Red

Blinks every

8 sec.

Battery is low

None

Completely

Off

Battery is dead

or disconnected

POWER UP

When the controller is powered up (by installing the

battery or plugging in the optional AC adaptor), the dis-

play will briefly show the software version (example

“1.0”), then the number of days until the next automatic

sediment flush.

MANUALLY START A SEDIMENT FLUSH

After all installation steps have been completed, initiate

a manual sediment flush as follows:

1

. Press the CLEAN NOW button and hold it for at

least 2 seconds.  When the 2-digit display changes

to show moving dashes (See Figure 14), release the

CLEAN NOW button.

2

. Check drain hose to ensure a secure connection.

3

. The sediment flush sequence takes about 30 sec-

onds to complete.  The flow of water to the drain will

start and stop several times.

4

. Once the sediment flush has been completed, the 2-

digit display will change to show the number of days

until the next automatic flush (or if the automatic

flush feature has been turned off it will show “- -”).

The ASF can be manually activated to flush sediment

at any time, regardless of whether or not it is set to

flush automatically.

NORMAL OPERATION

During normal operation, the LED will momentarily

blink green every 8 seconds and the 2-digit display

(LCD) will show the number of days remaining until the

next automatic sediment flush.  Momentarily pressing

the PROGRAM button shows the setting for the num-

ber of days between flushes.

LCD BACKLIGHT

The 2-digit display has a backlight that goes on  when-

ever a button is pressed.  It goes off again after 10

seconds if no more buttons have been pressed (to

conserve battery life).  Momentarily press either the

PROGRAM or CLEAN NOW button to turn on the

backlight.

Moving dashes

indicate sedi-

ment flush is

taking place

FIG. 14

LED

(see

Table below)

2-Digit LCD

Display

(when unit is in

normal opera-

tion, shows

number of days

until next auto-

matic sediment

flush)

FIG. 15

Содержание EP-ASF15

Страница 1: ...Friday 7 AM 6 PM CST or visit www ecopure com U S A www ecopure ca Canada When you call please be prepared to provide the model date code and serial number of your product found on the rating decal lo...

Страница 2: ...disposed of accord ing to Waste Electrical and Electronic Equipment WEEE requirements This directive or similar laws are in place nationally and can vary from region to region Please refer to your sta...

Страница 3: ...urther that the Automatic Sediment Filter is not damaged as the result of any unusu al force of nature such as but not limited to flood hurricane tornado or earthquake Warrantor is excused if failure...

Страница 4: ...1 8 in 5 1 4 in 9V Battery Hose Clamp INSPECT SHIPMENT The Automatic Sediment Filter is shipped complete in one carton Remove all items from the shipping carton and check against the packing list bel...

Страница 5: ...ediment Filter is designed to be plumbed into a home s incoming water supply pipe where it will capture particles of sediment from the water and periodically flush them down the drain The unit has an...

Страница 6: ...s top cover and observe the IN and OUT markings Depending on the direction of water flow and the viewing angle the faceplate may need to be reversed turned around to face the opposite direc tion so t...

Страница 7: ...8 CMR shall be adhered to A licensed plumber shall be used for this installation AIR GAP REQUIREMENTS A drain is needed for sediment flush discharge water A floor drain close to the Automatic Sediment...

Страница 8: ...llowing before turning the water supply back on 1 Measure cut to needed length and connect the 3 8 in drain line provided to the Automatic Sediment Filter s valve drain fitting See Figure 8 on Page 7...

Страница 9: ...Parts List page for ordering information IMPORTANT Do not use any AC adaptor other than the EcoPure P N 7302835 with this Automatic Sediment Filter To install the optional AC adaptor 1 Remove the top...

Страница 10: ...in will start and stop several times 4 Once the sediment flush has been completed the 2 digit display will change to show the number of days until the next automatic flush or if the automatic flush fe...

Страница 11: ...increases the number of days by 1 When the number passes 30 it returns to zero indicated by and counts up from 1 again 3 Setting the number of days to zero turns off the automatic flush feature 4 When...

Страница 12: ...e water you saved in Step 1 wash the filter screen assembly If necessary gently scrub the filter mesh with a soft brush to remove material from the pores 7 The drain straw may have come out of the ASF...

Страница 13: ...off the water supply as directed in Step 2 run a bucketful or sinkful of water to use for cleaning 2 Shut off the main house water supply valve upstream from the Automatic Sediment Filter 3 Open a col...

Страница 14: ...Head Assembly 17 7300312 O Ring Sump 18 7298395 Sump 19 7300304 Drain Straw Key No Part No Description 20 7298808 Filter Screen Assembly 60 Micron includes Key No 21 7298816 Filter Screen Assembly 100...

Отзывы: