INSTALLATION

ELECTRICAL WIRE CONNECTION

OVERLOAD PROTECTION

       

 

Do not work on pump until    

       

 

power is unplugged. 

       

 

Do not cut off ground pin or   

       

 

use an adapter fitting. 

Do not use an extension cord.   

 

 

The pump power cord should be connected to a 

separately fused, grounded line with a minimum  

capacity of 15 amps. It can be connected to non-

fuse breaker at the recommended amperes. 
1. Before installing or servicing this pump, be    

  certain pump’s power source is disconnected. 

2. Installation and electrical wiring must adhere  

  to state and local codes and must be   

 

  completed before priming pump. Check  

 

  appropriate community agencies, or contact   

  local electrical and pump professionals. 

3. Call an electrician when in doubt. Pump  

 

  should be connected to a separate 15  

 

  amp circuit breaker or 15 amp fuse block.    
Note that plugging into existing outlets may    

cause low voltage at motor. This could cause    

blown fuses, tripping of motor overload or  

 

burned out motor. 
4. A permanent ground connection from pump    

  to the grounding bar at the service panel is    

  mandatory. These sump pumps come with a   

  grounding conductor and a grounding-type   

  attachment plug. Do not connect pump to    

  a power supply until permanently grounded.   
For maximum safety, connect pump to a circuit  

equipped with a fault interrupter device when  

positioning the pump’s grounding wire. 

5. Voltage of power supply must match the    

  voltage of the pump.  

6. Before installing pump, clear sump basin of   

  any water, debris or sediment.   

 

 

       

 

Sump basin must be vented 

       

 

in accordance with local 

plumbing codes. These Sump pumps are not  

designed for and CANNOT be installed in loca-

tions classified as hazardous.   
7.  The following may cause injury and/or severe  

  damage to pump and will void the warranty. 

   (a) Using an extension cord. 

 

(b) Cutting off the ground pin or using an    

       adapter fitting. 

  (c) Working on pump or switch while  

    plugged in.

  (d) Removing motor housing, unscrewing    

    impeller, or otherwise removing impeller seal. 

  (e) Running the pump continuously. 

  (f)  Pumping chemicals or corrosive liquids. 

  (g) Pumping gasoline or other flammable liquids

  (h) Installing pump on a shared circuit. 
8. Plastic PVC pipe can be installed in the  

 

  outlet piping. Drain hose, galvanized steel    

  or copper pipe may be used if desired.  

 

  All piping must be clean and free of all  

 

  foreign matter to prevent clogging. 

9. Pump will be inadequate if suspension  

 

  liquids contain solid particles larger than 1/4”. 

     

   

Verify that the voltage and    

     

   

frequency of the pump shown 

on the nameplate corresponds to those available on 

the mains. The installer must make sure that the  

electric system is grounded in accordance with code. 
•  For outdoor use it is necessary to use cable with  

  a length of  at least 8’. The plug and connection  

  should be protected from water splashes. Before  

  using the pump, always inspect it visually  

 

  (especially power cable and plug) 

•  Do not use pump if it is damaged 

•  If the pump is damaged, have it inspected by an  

  authorized service center. 

•   Make sure that electric connections are protected  

  from flooding. Protect the plug and the power   

  cable from heat or sharp edges. 

    

     

   

The power cable must be 

     

   

replaced by qualified personnel 

only. Grounding: The plug of the power cable has a 

double grounding contact, so that grounding can be 

performed by simply inserting  the plug. 

This pump series has a built in thermal protection 

switch. The pump stops if an overload condition  

occurs. The motor restarts automatically after it has 

cooled down. If it doesn’t start automatically, unplug 

the pump and plug it back in.

4

Содержание EFWIFI33

Страница 1: ...azard which if not avoided will result in death or serious injury Indicates a hazard which if not avoided could result in death or serious injury Indicates a hazard which if not avoided could result i...

Страница 2: ...Over Temperature Battery status Faulty level sensor Faulty relay Wireless signal low or lost Push notifications are also sent when fault conditions are cleared HISTORY The app will record pump histor...

Страница 3: ...d Construction Impeller Length Pumped EFWIFI33 1 3 115 1 4 3480 22 Cast Iron Thermoplastic 10 1 2 3 MAC Address and Bar Code LED Status Indicator Silence Test Button SMART PUMP CONTROLLER Unlock Setup...

Страница 4: ...ing may cause injury and or severe damage to pump and will void the warranty a Using an extension cord b Cutting off the ground pin or using an adapter fitting c Working on pump or switch while plugge...

Страница 5: ...rface Never place pump directly on clay earth or gravel surfaces Pump can be installed with ABS PVC polyethylene or galvanized steel pipe Proper adapters are required to connect plastic pipe to pump A...

Страница 6: ...e controller back on the screws already in the wall 6 Continue to follow instructions in the app until setup is complete The instructions within the app will guide you through the following steps a En...

Страница 7: ...l times by plugging in and unplugging cord Check for clogged vent hole in pump case Vertical pumping distance is too high Reduce distance or change the discharge fitting of the pump Inlet holes in pum...

Страница 8: ...defect Manufacturer will subsequently take corrective action as promptly as reasonably possible No requests for service will be accepted if received more than 30 days after the warranty expires Warran...

Страница 9: ...la instalaci n operaci n y mantenimiento del producto Guarde este manu al para consultas en el futuro Etiquetas de seguridad Este es un s mbolo de alerta de seguridad Cuando vea este s mbolo en su bo...

Страница 10: ...va Estado de la bater a Sensor de nivel defectuoso Rel defectuoso Se al inal mbrica baja o p rdida de se al El sistema tambi n env a notificaciones autom ticas cuando las condiciones de falla desapare...

Страница 11: ...Impulsor del cable bombeados EFWIFI33 1 3 115 1 4 3000 22 Hierro fundido Termopl astico 10 1 4 Direcci n MAC y c digo de barras LED indicador de estado Bot n de prueba CONTROLADOR DE LA BOMBA INTELIGE...

Страница 12: ...minal de tierra ni utilice un adaptador No utilice un cable de extensi n El cord n de alimentaci n el ctrica de la bomba debe conectarse a una l nea separada con fusibles y conex i n a tierra con una...

Страница 13: ...a puede instalarse con una tuber a de ABS PVC polietileno o acero galvanizado Se necesitar n adaptadores adecuados para conectar la tuber a de pl stico a la bomba Siempre instale una uni n doble en la...

Страница 14: ...puede volver a montar el controlador en los tornillos que ya est n en la pared 6 Siga las instrucciones de la aplicaci n hasta finalizar la instalaci n Las instrucciones de la aplicaci n lo guiar n a...

Страница 15: ...ra ver si hay un orificio de ventilaci n obstruido Los orificios de entrada de la base de la bomba est n obstruidos Extraiga la bomba y limpie las aberturas La distancia de bombeo vertical es demasiad...

Страница 16: ...se aceptar n solicitudes de servicio si se reciben m s de 30 d as despu s de la fecha de vencimiento de la garant a La garant a no es transferible y no se aplica a productos utilizados en aplicacione...

Страница 17: ...ravaillez sur des pompes Risque d explosion Le corps de pompe peut exploser si elle est utilis e comme pompe de surpression Importantes instructions de s curit Lisez attentivement et suivez toutes les...

Страница 18: ...Des notifications pouss es sont galement transmises lorsque les anomalies sont corrig es HISTORIQUE L application mobile enregistre l historique de la pompe et affiche sur demande des graphiques pr s...

Страница 19: ...h Amp res gal h 0 pi refoulement max Construction Impulseur du cordon pomp s EFWIFI33 1 3 115 1 4 3000 22 Fonte Thermoplastique 10 1 4 Adresse MAC et code barres Voyant d tat DEL Bouton d essai de sil...

Страница 20: ...sation d un cordon de rallonge b Coupe de la broche de terre ou utilisation d un raccord d adaptation c Travail sur la pompe ou le commutateur d un syst me rest branch d Ouverture du carter de moteur...

Страница 21: ...a pompe peut tre install e avec un tuyau en plastique ABS en PVC en poly thyl ne ou en acier galvanis Des adaptateurs appropri s sont n cessaires pour raccorder un tuyau en plastique sur la pompe Inst...

Страница 22: ...la prise murale avec un peu de mou a Installez deux vis de montage espac es de 5 3 4 po comme sur la figure 2 b V rifiez que le contr leur tient solidement sur le mur puis connectez le une prise mura...

Страница 23: ...entilation du carter de pompe n est pas obstru Les trous d admission dans la base de pompe sont obstru s Sortez la pompe et net toyez ses ouvertures La distance verticale de pompage est trop lev e R d...

Страница 24: ...titre de la garantie ne sera accept e si elle est re ue plus de 30 jours apr s la date d expiration de la garantie Cette garantie n est pas transf rable et ne s applique pas pour des produits utilis s...

Отзывы: