Fault

Fault/Action

Bottle cooler does not run and the 

light does not work 

 

Make sure the bottle cooler is plugged in securely

Check for a blown fuse or tripped circuit breaker

Inspect the electrical cord for damage

Eliminate use of an extension cord, if one is being used

Bottle cooler does not run but the 

light works

Check the temperature setting

Make sure there is sufficient ventilation at the rear, sides and top of

 

the bottle cooler to prevent overheating

Clean the condenser at the rear if accessible

Check the compressor is running

Bottle Cooler light does not work

Check the light switch is ON

Replace Starter

Replace the light tube/ LED tube

Bottle Cooler is not cold enough

Check the temperature setting

Make sure there is the sufficient ventilation at the rear , sides and top of the 

bottle cooler to prevent overheating

Ensure bottles are not blocking the vents

Clean the condensor at the rear if accessible

Check door seals are OK

Check internal fan is running

Bottle cooler is too cold

Check the temperature setting

Bottle cooler is noisy or makes a 

strange sound

check that the bottle cooler is level

Check the drainage

Check the evaporator fan is running

check the condensor fan is running if accessible

Water on the floor outside of bottle 

cooler

Clean the drainage point inside the bottle cooler

Water inside the bottle cooler

Clean the drainage point inside the bottle cooler

Trouble Shooting 

Содержание Platinum BBC

Страница 1: ...01 REVISION PRODUCT MANUAL E C O C O O L PLATINUM BBC Back Bar Cooler...

Страница 2: ...than 45o from the regular horizontal position Always allow the product to rest for at least 1 hour after transportation before switching it on 4 PLACEMENT For maximum performance this product should b...

Страница 3: ...o the equipment ensuring for adequate air circulation Always place items gently into the equipment never throw item as this may damage the insulated wall panels Adjusting the Temperature You can adjus...

Страница 4: ...www capitalproducts co uk 44 0 844 840 0555 Platinum BBC Plat 300 Plat 500 Wiring Diagram...

Страница 5: ...rbourne debris from the condenser unit and cooling fins located at the rear of the unit Exercise care not to damage fins Beware of the sharp fins and take care when cleaning this area 1 6 Condensate T...

Страница 6: ...cable becomes damaged please contact a qualified electrician or refrigeration engineer never attempt to fix it yourself NEVER OPERATE THIS PRODUCT WITH A DAMAGED POWER CABLE Always disconnect the equ...

Страница 7: ...k the light switch is ON Replace Starter Replace the light tube LED tube Bottle Cooler is not cold enough Check the temperature setting Make sure there is the sufficient ventilation at the rear sides...

Страница 8: ...ARNING the digital controller is set automatically from the factory to the optimum setting for efficiency and performance by adjusting this you may reduce both of these and possibly cause damage to th...

Страница 9: ...Buyer and whether for breach of Contract negligence breach of statutory duty or otherwise in respect of any claims proceedings damages losses costs and expenses whether direct or consequential and inc...

Страница 10: ...www capitalproducts co uk 44 0 844 840 0555 Platinum BBC Cosmetic Drawing 3 4 5 2 1 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Platinum 300...

Страница 11: ...ator down plate N A 10 K clip 122201 11 Light clip 122199 12 Lock 122039 13 Door seal 122169 14 A Right Glass door 122171 15 Shelves 122202 16 Fan cover 122097 17 LED light 122386 18 K strip 122384 19...

Страница 12: ...www capitalproducts co uk 44 0 844 840 0555 Platinum BBC Cosmetic Drawing Platinum 500 12 13 14 15 16 3 4 2 1 6 7 8 9 10 11 17 18 19 20 21 22 23 24 25 26 27 28 5...

Страница 13: ...e N A 10 K clip 122201 11 Light clip 122199 12 Lock 122039 13 Door seal 122387 14 A Right Glass door 122389 14 B Left Glass Door 122392 15 Shelves 122393 16 Fan cover 122097 17 LED light 122391 18 K s...

Страница 14: ...WAYS TO REGISTER FOR YOUR FREE 2 YEARS PARTS AND 1 YEAR LABOUR GUARANTEE 8 REGISTER ONLINE REGISTER BY MAIL Visit our website to register your full parts and labour guarantee online www capitalproduc...

Страница 15: ...www capitalproducts co uk 44 0 844 840 0555 Notes Product Manual...

Страница 16: ...Manual Contact Capital Products Head Office R D Facility Parts Call Centre 12 Dunnet Way East Mains Industrial Estate Broxburn West Lothian EH52 5NN Email technical capitalproducts co uk Tel 44 0 844...

Отзывы: