1.1.  Cleaning 

A regular and thorough cleaning regime is essential for 

the efficient and hygienic operation of your bottle cooler.

Before undertaking any cleaning operation, ALWAYS 

turn the case off and if possible, disconnect it from the 

mains power supply.

Avoid water splashing onto the case’s electrical 

elements. If water splashing occurs, make sure that 

all electrical components are thoroughly dry before 

reconnecting to the power supply. Never use abrasive 

or caustic cleaning agents.

1.2.  Exterior/Internal surfaces 

Painted or metal surfaces should be cleaned with a 

cloth soaked in warm soapy water. Surfaces should be 

dried with soft cloth. Shelves should be removed for 

cleaning as above.

1.3.  Glass & Mirror

Glass and mirrored surfaces should be cleaned with a 

suitable glass cleaner. Glass and mirrored surfaces may 

be wiped with a  soft dry cloth.

1.4.  Evaporator Fans

Ensure fans are NOT running when cleaning the fan 

blade.

Clean around evaporator fans 

1.5.  Air cooled Condenser and Cooling Fins

Carefully vacuum dust and airbourne debris from the

condenser unit and cooling  fins located at the rear of 

the unit. Exercise care not to damage  fins.

Beware of the sharp  fins and take care when cleaning

this area.

1.6.  Condensate Tray

The self-evaporating water tray which collects defrost 

water should be cleaned regularly.

Spilled milk and other dairy products collecting in 

the condensate tray may lead to odor and should be 

cleaned immediately.

1.7.  Water Outlets 

Outlets for waste water should be cleaned regularly to 

ensure continuous flow of waste water.

Maintenance

The condensor coil located at the rear of the unit 

should be kept clean and clear for maximum 

efficency.

When loading the cabinet:

•  ensure you do not block the air duct located at 

the back of the unit and the fan on the roof panel

•  blocking the airflow from these will cause a 

decrease in performance

•  for maximum performance maintain at least 

50mm of clearance between the contents and the 

air duct

Shelves can be adjusted to suit your needs. Always 

ensure that they are secure before loading with 

products.

The temperature controller is located at the bottom 

of the unit and is set to ‘4 °C’ as default.

Do not leave the door open for prolonged periods of 

time. For maximum efficiency close door immediately 

after use.

Cleaning & General Maintenance 

Содержание Platinum BBC

Страница 1: ...01 REVISION PRODUCT MANUAL E C O C O O L PLATINUM BBC Back Bar Cooler...

Страница 2: ...than 45o from the regular horizontal position Always allow the product to rest for at least 1 hour after transportation before switching it on 4 PLACEMENT For maximum performance this product should b...

Страница 3: ...o the equipment ensuring for adequate air circulation Always place items gently into the equipment never throw item as this may damage the insulated wall panels Adjusting the Temperature You can adjus...

Страница 4: ...www capitalproducts co uk 44 0 844 840 0555 Platinum BBC Plat 300 Plat 500 Wiring Diagram...

Страница 5: ...rbourne debris from the condenser unit and cooling fins located at the rear of the unit Exercise care not to damage fins Beware of the sharp fins and take care when cleaning this area 1 6 Condensate T...

Страница 6: ...cable becomes damaged please contact a qualified electrician or refrigeration engineer never attempt to fix it yourself NEVER OPERATE THIS PRODUCT WITH A DAMAGED POWER CABLE Always disconnect the equ...

Страница 7: ...k the light switch is ON Replace Starter Replace the light tube LED tube Bottle Cooler is not cold enough Check the temperature setting Make sure there is the sufficient ventilation at the rear sides...

Страница 8: ...ARNING the digital controller is set automatically from the factory to the optimum setting for efficiency and performance by adjusting this you may reduce both of these and possibly cause damage to th...

Страница 9: ...Buyer and whether for breach of Contract negligence breach of statutory duty or otherwise in respect of any claims proceedings damages losses costs and expenses whether direct or consequential and inc...

Страница 10: ...www capitalproducts co uk 44 0 844 840 0555 Platinum BBC Cosmetic Drawing 3 4 5 2 1 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 Platinum 300...

Страница 11: ...ator down plate N A 10 K clip 122201 11 Light clip 122199 12 Lock 122039 13 Door seal 122169 14 A Right Glass door 122171 15 Shelves 122202 16 Fan cover 122097 17 LED light 122386 18 K strip 122384 19...

Страница 12: ...www capitalproducts co uk 44 0 844 840 0555 Platinum BBC Cosmetic Drawing Platinum 500 12 13 14 15 16 3 4 2 1 6 7 8 9 10 11 17 18 19 20 21 22 23 24 25 26 27 28 5...

Страница 13: ...e N A 10 K clip 122201 11 Light clip 122199 12 Lock 122039 13 Door seal 122387 14 A Right Glass door 122389 14 B Left Glass Door 122392 15 Shelves 122393 16 Fan cover 122097 17 LED light 122391 18 K s...

Страница 14: ...WAYS TO REGISTER FOR YOUR FREE 2 YEARS PARTS AND 1 YEAR LABOUR GUARANTEE 8 REGISTER ONLINE REGISTER BY MAIL Visit our website to register your full parts and labour guarantee online www capitalproduc...

Страница 15: ...www capitalproducts co uk 44 0 844 840 0555 Notes Product Manual...

Страница 16: ...Manual Contact Capital Products Head Office R D Facility Parts Call Centre 12 Dunnet Way East Mains Industrial Estate Broxburn West Lothian EH52 5NN Email technical capitalproducts co uk Tel 44 0 844...

Отзывы: