39
6.
Select the hardware.
In the hardware configuration window, right click the “HWK
Workspace” listed under the section text “1. Hardware Devices”, and select Insert.
Select the ETAS device you wish to use. In this example, we are using an ETAS
ES591.1. Expand the selection tree by clicking the “+” next to the hardware device
model. Expand the CAN selection and select CAN-Monitoring. Click OK.
7.
Associate the dbc.
When you clicked OK in the last step, another window will pop
up that will allow you to select a dbc that you have added to your workspace from
step 4. Expand the selection tree, select your dbc file, and click OK.
Содержание egrCAN
Страница 6: ...2 Figure 1 Basic egrCAN System...
Страница 32: ...28 Appendix A egrCAN Kit Contents Basic System...
Страница 51: ......