30
Appendix B: Module Stand-alone Mode and EIB Mode
CAN data from LambdaCAN and NOxCAN(g) modules can either be taken directly from the
modules themselves or from the CAN port of display heads connected to the modules. When
data is taken directly from one or more modules, each module must in Stand-alone mode.
When data is taken from one or more display heads of an EGR 5210, Lambda 5220, or EGR
5230 analyzer, each module must be in EIB mode.
Therefore, the module must be properly configured in Stand-alone mode or EIB mode
depending on how it will be used. When LambdaCAN and NOxCAN(g) modules are sold
alone, they are delivered in Stand-alone mode. When LambdaCAN and NOxCAN(g)
modules are sold as part of a NOx 5210, Lambda 5220, or EGR 5230 analyzer, they are
delivered in EIB mode.
To convert from one mode to the other requires software reprogramming of the module
followed by the installation (to set to Stand-alone) or removal (to set to EIB) of a jumper
inside the module.
To convert a module from EIB to Stand-alone Mode
1. Take the nut off the end of the module. Use an 18mm socket without the wrench.
2.
Release the two tangs at each side of the module.