23
Setup Option Level 1
Function
MOd
Select module s/n. Default is NONE.
RATE
Set parameter averaging rate. Range 0.001 to 1.000
Default is 1.000
dISP
Select parameter. Note: Parameters available are
those programmed using Configuration Software.
CONF LEdS
Set display intensity. Default is 3333.
LOCK
Lock and Unlock Display for Programming
MOd, RATE, and dISP appear on the upper display for the upper channel and on the lower
display for the lower channel. CONF just appears on the lower display and is for global
dashCAN setup. All entries must be followed by pressing the ENT key.
Table 6: Menu Tree for dashCAN
MOd (Module) Setup Option
In MOd setup, the serial number of the module assigned to the upper or lower channel is
entered. The serial number is written on a label on the module. The module assigned to the
upper channel will send information to the upper display and the module assigned to the
lower channel will send information to the lower display. The same module can be assigned
to both channels or different modules can be assigned to each channel.
After entering MOd (i.e. press ENT when “MOd” is displayed), the serial numbers of the
available modules will be displayed. Select using
↑
and
↓
followed by the ENT key.
RATE Setup Option
Data is transmitted from modules at the broadcast rate and the programmed averaging that
was programmed using the Configuration Software. This transmitted data can then be
further averaged before being displayed on the displays. Separate averaging can be
programmed for the upper display and the lower display.
The averaging is programmed with values from 0.001 (heavy averaging) to 1.000 (no
averaging). The default is 1.000. The averaging is performed as follows:
DisplayedValue
t
=
α
x Parameter
t
+ (1 –
α
) x DisplayedValue
t-1
where:
DisplayedValue
t
= the new displayed value
α
= The user-programmable averaging.
Range: 0.001 (heavy averaging) to 1.000 (no averaging).
Parameter
t
= the latest value transmitted by the module
DisplayedValue
t-1
= the previous displayed value
The selected display averaging does not affect the module’s CAN transmission rate or
averaging.