5. 3. 2. 3 FUNCTIONING IN CASE OF POWER FAILURE
1. Manual open:
In case of power failure E-MOTION automatic control allows the door to be opened manually just with a
push, obtaining a simple opening.
5. 3. 3 USE RESTRICTION
It’s useful to show, assist and advise the client on the correct use of internal sliding doors with
E-MOTION automatic control, if they are installed where there are people with physical, sensorial
and mental reduced capacities, children and old people.
Do not allow children to play in the door passage, and keep the remote control out of their reach.
5. 4 MAINTENANCE
The product doesn’t need particular periodic maintenance operations. It’s necessary, under the
§ 4.2 of EN 16005 law, verifying at least once a year the correct functioning of the security
devices.
PROBLEM
POSSIBLE CAUSE
SOLUTION
“On / off” button light doesn’t
switch on.
The automatic control isn’t
connected to the power grid
(connector, direct terminal box,
thermic connection / differential,
etc.)
Control the connection and verify the
correct voltage, 230V - 50Hz.
Defective internal connection.
Control the internal connection.
IMPORTANT! Carry out these
operations with the guide
disconnected!
The fuse is burned.
Verify the fuse with a tester.
The switch isn’t on ON position.
Move the switch on ON position.
The door doesn’t move and no
light switches on.
The system isn’t powered (internal
failure).
Contact the technical staff.
The door doesn’t move and
the lights switch on in start-up
sequence.
Defective motor connection.
Contact the technical staff, control
internal connections between
motor and control card.
5. 5 PROBLEMS AND SOLUTIONS