P0016-LI-02.01
11
Remote Keypads
PCB Layouts
3
4
2
1
LED Remote Keypad
1
2
3
4
LCD Remote Keypad
1. Network Connections
The remote keypad is connected to the network terminals located
at the bottom left hand side of the PCB.
2. Address Selection
Each remote keypad must be assigned a different address using
the Address selector. Move the jumper to the required position 1,
2, 3 or 4.
3. Tamper Switch
The lid tamper for each remote keypad can be enabled or
disabled if required. Please refer to page 28 for further details.
4. Piezo Sounder
The piezo sounder generates low level alarm, key press, and
warning tones. Each type of tone can be enabled or disabled for
each remote keypad, please refer to page 28 for further details.
Wiring Detection Devices
The EC-P10 provides 10 zones for connecting detection devices
such as movement sensors and magnetic door contacts. Each
zone is fully programmable to allow for maximum flexibility (see
page 19 for Zone Programming details). The program options for
a zone will also determine how the zone may be wired. The
following wiring options are available:
Normally Closed
This wiring configuration should be used when connecting
detection devices that only have a normally closed alarm output.
Connect the detector as shown below and ensure that the zone is
programmed for “Normally Closed” operation, see page 20.
Zy
Zx Com
Alarm
1 Detector
Alarm
Alarm
2 Detectors
Normally Open
This wiring configuration should be used when connecting
detection devices that only have a normally open alarm output.
Connect the detector as shown below and ensure that the zone is
programmed for “Normally Open” operation, see page 20.
Zy
Zx Com
Alarm
1 Detector
Alarm
Alarm
2 Detectors