ECL-ACC997 / ECL-ACC999
V121203
Command List
(
By WG Keyboard
)
Function
Command
Exposition
Entering programming mode
PPPPPP
PPPPPP: Master Code, (Default value: 123456)
Exiting programming mode
Exiting programming mode and enabling all device
into arming status.
Including ECL-ACC997 / ECL-ACC999, WG Reader
Enabling each device into arming status.
U
U
=
Enable target unit
(
0=ECL-ACC997/ECL-ACC999
,
1=WG Reader
)
Node ID setting
00 NNN MMM AAA
NNN
=
Node ID,(001~254)
MMM
=
ECL-ACC997/ECL-ACC999 Door Number,
(001~255)
AAA
=
WG Reader Door Number,(001~255)
IP Address assign (Must power reset)
01 0 CCCCCCCCCCCC
default value = 192.168.1.127
CCCCCCCCCCCC = 192168001127
If set to 000.000.000.000 will enable DHCP otherwise
will disable DHCP
01 1 255255255000
Netmask
01 2 192168001254
Gateway assign
Door relay time setting
02 U TTT
U
=
Enable target unit
(
0=ECL-ACC997/ECL-ACC999
,
1=WG Reader
)
TTT
=
Door relay time
000 (Output constantly)
001~600
=
1-600 Sec.
;
601~609
=
0.1~0.9Sec.
Alarm relay time setting
03 TTT
TTT
=
Alarm relay time
;
000 (Output constantly)
001~600
=
1~600
Sec.
Arming delay time setting
05 TTT
Base on second, range: 001~255
Alarm delay time setting
06 TTT
Base on second, range: 001~255
Master card setting
07 SSSSS EEEEE
SSSSS-EEEEE
=
00000~15999
SSSSS= starting user address; EEEEE= ending user address
Auto-open zone setting
08 MW NN HHMMhhmm
7123456H
M=ACC-997/ACC-999; W=WG Reader
(0=disable; 1=enable)
NN
=
16 sets of auto-open zone (Range: 00~15)
HHMMhhmm=staring time to ending time
(e.g.: 08301200=08:30 to 12:00)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
Master code settings
09 PPPPPPRRRRRR
PPPPPP= New master code
RRRRRR= Repeat the new master code
Suspend or delete tags
Suspend
:
10 SSSSS EEEEE
:Suspend :Delete
SSSSS= starting user address; EEEEE= ending user address
Delete
:
10 SSSSS EEEEE
Recover tag
11 SSSSS EEEEE
SSSSS= starting user address; EEEEE= ending user address
Setting up Card or PIN mode by user address
12 UUUUU PPPP
UUUUU= user address; PPPP=4-digit individual PWD
(Access mode: Card or PIN)
Arming output setting
14 TTT
Base on 1ms, range:1~255, default value=10,
Input 0= Timeless
Duress code setting
15 PPPP
PPPP
=
4-digit PWD (0001-9999)
Default value
:
4321
Arming PWD setting
17 PPPP
PPPP
=
4-digit PWD (0001-9999)
Default value
:
1234
Enabling or Disabling into arming status
Card+
NNNN
NNNN
:
Arming PWD
U
=
Enable target unit
(
0=ECL-ACC997/ECL-ACC999
,
1=WG Reader
)
Enabling or Disabling each device into arming status.
Card
+
NNNN U
Enabling all device into arming status.
Card
+
NNNN
Disabling
all device into arming status.
Card
+
NNNN
Door open waiting time
18 U TTT
U
=
Enable target unit
(
0=ECL-ACC997/ECL-ACC999
,
1=WG Reader
)
TTT=Door open waiting time:001~600;default value:15 sec.
Set the card by induction
19 UUUUU QQQQQ
Reader additional setting
20 U DDD
U
=
Enable target unit
(
0=ECL-ACC997/ECL-ACC999
,
1=WG Reader
)
DDD=Function default value
Lift control setting: multi-doors
21 UUUUU G LLLLLLLL
UUUUU
=
user address
;
G=4 sets of lift control(0~3);
LLLLLLLL=8 assigned floor (F=0: Disable, 1: Enable)
AR-401RO16/ AR-401RO16B relay time setting
23 MMM TTT
MMM=Node ID of lift controller
TTT= relay time: 000~600=1~600 sec.
Factory setting
24 U DDD
U
=
Enable target unit
(
0=ECL-ACC997/ECL-ACC999
,
1=WG Reader
)
DDD
:
Function default value
Real time clock setting
25 YYMMDDHHMMSS
YYMMDDHHmmSS: Year/Month/Day/Hour/Min./Sec.
9
9
9
QQQQQ=Card quantity(00001=Continuously inducting)
UUUUU
=
user address