Command List 

(

By WG Keyboard

)

Function

Command

Exposition

Entering programming mode

     PPPPPP

PPPPPP: Master Code, (Default value: 123456)

 Exiting programming mode
 Exiting programming mode and enabling all device 

into arming status.

Including ECL-ACC997 / ECL-ACC999, WG Reader

Enabling each device into arming status.

           U

U

Enable target unit

 

(

0=ECL-ACC997/ECL-ACC999

,

1=WG Reader

)

Node ID setting

00      NNN     MMM     AAA

NNN

Node ID,(001~254)

MMM

ECL-ACC997/ECL-ACC999 Door Number,

(001~255)

AAA

WG Reader Door Number,(001~255)

IP Address assign (Must power reset)

01      0     CCCCCCCCCCCC

default value = 192.168.1.127
CCCCCCCCCCCC = 192168001127
If set to 000.000.000.000 will enable DHCP otherwise 

will disable DHCP

01      1     255255255000

Netmask

01      2     192168001254

Gateway assign

Door relay time setting

02      U      TTT

U

Enable target unit

 

(

0=ECL-ACC997/ECL-ACC999

,

1=WG Reader

)

TTT

Door relay time

000 (Output constantly)
001~600

1-600 Sec.

601~609

0.1~0.9Sec.

Alarm relay time setting

03      TTT

TTT

Alarm relay time

000 (Output constantly)

001~600

1~600

 

Sec.

Arming delay time setting

05      TTT

Base on second, range: 001~255

Alarm delay time setting

06      TTT

Base on second, range: 001~255

Master card setting

07      SSSSS      EEEEE

SSSSS-EEEEE

00000~15999

SSSSS= starting user address; EEEEE= ending user address

Auto-open zone setting

08      MW      NN      HHMMhhmm     
7123456H

M=ACC-997/ACC-999; W=WG Reader

 (0=disable; 1=enable)

NN

16 sets of auto-open zone (Range: 00~15)

HHMMhhmm=staring time to ending time
(e.g.: 08301200=08:30 to 12:00)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)

Master code settings

09      PPPPPPRRRRRR

PPPPPP= New master code
RRRRRR= Repeat the new master code

Suspend or delete tags

Suspend

10     SSSSS     EEEEE

    

:Suspend         :Delete

SSSSS= starting user address; EEEEE= ending user address

Delete

:  

10     SSSSS     EEEEE

Recover tag

11      SSSSS      EEEEE

SSSSS= starting user address; EEEEE= ending user address

Setting up Card or PIN mode by user address

12      UUUUU     PPPP

UUUUU= user address; PPPP=4-digit individual PWD
(Access mode: Card or PIN)

Arming output setting

14      TTT

Base on 1ms, range:1~255, default value=10, 
Input 0= Timeless

Duress code setting

15      PPPP

PPPP

4-digit PWD (0001-9999)

Default value

4321

Arming PWD setting

17      PPPP

PPPP

4-digit PWD (0001-9999)

Default value

1234

Enabling or Disabling into arming status

Card+

NNNN

NNNN

Arming PWD

U

Enable target unit

 

(

0=ECL-ACC997/ECL-ACC999

,

1=WG Reader

)

Enabling or Disabling each device into arming status.

Card

+

NNNN        U

Enabling all device into arming status.

Card

+

NNNN

Disabling

 all device into arming status.

Card

+

NNNN

Door open waiting time

18      U      TTT

U

Enable target unit

 

(

0=ECL-ACC997/ECL-ACC999

,

1=WG Reader

)

TTT=Door open waiting time:001~600;default value:15 sec.

Set the card by induction

19      UUUUU     QQQQQ

Reader additional setting

20      U      DDD

U

Enable target unit

 

(

0=ECL-ACC997/ECL-ACC999

,

1=WG Reader

)

DDD=Function default value

Lift control setting: multi-doors

21      UUUUU     G      LLLLLLLL 

UUUUU

user address

G=4 sets of lift control(0~3); 

LLLLLLLL=8 assigned floor (F=0: Disable, 1: Enable)

AR-401RO16/ AR-401RO16B relay time setting

23      MMM     TTT 

MMM=Node ID of lift controller
TTT= relay time: 000~600=1~600 sec.

Factory setting

24      U     DDD

U

Enable target unit

 

(

0=ECL-ACC997/ECL-ACC999

,

1=WG Reader

)

DDD

Function default value

Real time clock setting

25      YYMMDDHHMMSS

YYMMDDHHmmSS: Year/Month/Day/Hour/Min./Sec.

9

9

9

QQQQQ=Card quantity(00001=Continuously inducting)

UUUUU

user address

Содержание ECL-ACC997

Страница 1: ...ED Output 5V 20mA Max 3 Brown Green LED Output 5V 20mA Max Door Output 4 Blue White Transistor Output Max 12V 100mA Open Collector Active Low Wiegand 5 Thin Green Wiegand DAT 0 Input 6 Thin Blue Wiega...

Страница 2: ...ontroller RTE RTE RTE RTE RTE POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC Magnet Lock Connect to Ele...

Страница 3: ...C997 ACL ACC999 set to exit reader WG Reader set to access reader Access programming mode 20 0 128 20 1 192 Please refer to function default value for details Enable Disable auto open zone Access prog...

Страница 4: ...digit arming code Enable particular device Induct valid card Input 4 digit arming code U or Disable particular device Induct valid card Input 4 digit arming code U or Input 5 digit user address Input...

Страница 5: ...n where finger can easily be placed 2 Use the middle or ring finger of either hand for the registration authentication purpose 3 Put your finger tip first to the top of the unit and lower the finger d...

Страница 6: ...sticker on Ethernet Module device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password c...

Страница 7: ...r code settings 09 PPPPPPRRRRRR PPPPPP New master code RRRRRR Repeat the new master code Suspend or delete tags Suspend 10 SSSSS EEEEE Suspend Delete SSSSS starting user address EEEEE ending user addr...

Страница 8: ...99 En Disable Skip Finger Tag 40 F NNNNN EEEEE First 40 1 NNNNN EEEEE Then 40 3 NNNNN EEEEE Function Default Value 20 U DDD Default Value Function Option Value Application Time Attendance 0 Yes 1 No 0...

Отзывы: