V121203
Fingerprint & Finger Vein
Biometrics Device Access controller
Command List
(
By WG Keyboard
)
Function
Command
Exposition
Anti-pass-back (Enable user)
26 SSSSS EEEEE P
SSSSS= starting user address; EEEEE= ending user address
P=0=Enable; P=1=Disable; P=2=Initial
Lift control setting: single door
27 UUUUU LL
UUUUU
=
user address
;
LL
:
Floor number(01~64 floor)
Duress Function and Arming output setting
28 FFF
Arming output and Duress function: FFF= 008 (default value)
Delete all tag
29 29
Same tag reading interval time
31 TTTT
Base on 10ms, range from 10 to 6000
Auto ring the clock alarm schedule
32 SS HHMMTT 7123456H
SS= 16 sets auto alarm schedule, range 0~15
HHMM= HH:MM (ex. 0830: Ring bell at 08:30)
TT=Period of time to ring bell
(Base on second, range 01~99 sec.)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
Holiday Setting
35 MMDD F
MM= Month of year (01=Jan...10=Oct.)
DD= Date of month (01=1st day of month)
F= 0:Delete ; 1: Add
Enabling or Disabling into Full Access status
36 MW
M=ACC997/ACC-999; W=WG Reader
(0=disable; 1=enable)
RS485 port function setting
(Needs to be restarted after setting)
37 AB
A
=
0:AR401RO B
=
0: 9600(default value)
1:Host (default value) 1: 19200
2:LED Panel 2: 38400
3:Printer 3: 57600
Biometric forms set
(Needs to be restarted after setting)
38 DDD
002
=
2000 Finger-Vein recognition
003
=
9000 Optical / Capacitive fingerprint recognition
004
=
200 Optical fingerprint recognition
008
=
200 Capacitive fingerprint recognition
012
=
200 Optical & Capacitive fingerprint recognition
Adding / Deleting Fingerprint or Finger-Vein
39 F UUUUU
F
=
1: Adding one finger data
2: Adding two finger data
0: Delete
UUUUU
=
user address
Deleting All Fingerprint or Finger-Vein
39 9 99999
En/Disable Skip Finger/Tag
40 F NNNNN EEEEE
First 40*1*
NNNNN*EEEEE#
Then 40*3*
NNNNN*EEEEE#
Function Default Value
20 U DDD
※
Default Value
Function
Option
Value Application
Time Attendance
※
0: Yes
1: No
001 Networking
Auto Re-lock
※
0: Disable 1: Enable 002 Networking/Stand-Alone
Auto Open
※
0: Disable 1: Enable 004 Networking/Stand-Alone
When Access Mode is "Card and PIN", Readers can skip pressing PIN code.
※
0: Disable 1: Enable 008 Networking/Stand-Alone
Exit by Push Button
0: Disable
※
1: Enable 016 Networking/Stand-Alone
Enable force Open
※
0: Slave 1: Mater
032 Networking
As Access/Exit Reader
※
0: Exit
1: Access 064 Networking
Anti-pass-back
※
0: Disable 1: Enable 128 Networking
28 FFF
Function
Option
Value
Application
※
Default Value
Duress Function and Arming output setting
0:Wiegand output
Networking/Stand-Alone
008
※
1: Arming and Duress
※
HOST: 01
RS-485
401RO16B:00
000
016
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
PRN: 11
LED: 10
032
048
Expiry User Access Trigger Alarm
Auto Reset Anti-pass on TZ61
※
0:Disable
※
0:Disable
1:Enable
1:Enable
001
002
Access mode: FP first and then Tag (Default Value)
setting a pair of command
setting a pair of command
Access mode: FP only or Tag only
First 40*0*
NNNNN*EEEEE#
Then 40*2*
NNNNN*EEEEE#
NNNNN= starting user address;EEEEE= ending user address
24 U DDD
※
Default Value
Function
Option
Value Application
Enable Egress Beep Sounds
※
0: Disable 1: Enable
001 Networking/Stand-Alone
Skip Tag after FP Access
※
0: Disable 1: Enable
002 Networking/Stand-Alone
Enable Arm/Disarm Zone(62)
※
0: Disable 1: Enable
008 Networking/Stand-Alone
Reader and controller share the same door relay (only for reader)
0: Disable
※
1: Enable
016 Networking/Stand-Alone
Free Access Mode
※
0: Disable 1: Enable
032 Networking/Stand-Alone
Stop Alarm by...
※
0: None
1: Push button/Door Closed 064 Networking/Stand-Alone
Open door immediately without 1st card presented at auto open zone
※
0: Disable 1: Enable
128 Networking/Stand-Alone