background image

V121203

    

Fingerprint & Finger Vein

Biometrics Device Access controller 

E. Lift control

Single floor

[e.g.] User address NO. 45 only can reach the elevator to the 24th floor:

 

27     00045     24

Access programming mode

 → 

27     UUUUU     LL

UUUU=User Address LL=Floor number (01~64 floor)

Connect with 

Lift Controller

 to control floors which the user will be able to access. [BAUD9600]

Set
(G)

Floor

L

8

16

24

32

40

48

56

64

0

1

2

3

4

5

6

7

L

6

14

22

30

38

46

54

62

L

7

15

23

31

39

47

55

63

L

5

13

21

29

37

45

53

61

L

4

12

20

28

36

44

52

60

L

3

11

19

27

35

43

51

59

L

2

10

18

26

34

42

50

58

L

1

9

17

25

33

41

49

57

Please refer to below floor chart

[e.g.] User address NO. 168 can reach only the 6th and 20th floor:
        Access programming mode

 → 

21     00168     0     00100000

        

→ 

21     00168     2     00001000

     →  

OK (Please refer to floor chart as right.)

 

Multi floors

Access programming mode

 → 

21     UUUUU     G     LLLLLLLL

[UUUUU=User address G: 8 sets of lift control (Input: 0~7) LLLLLLLL: 
8 floors setting (L=0=Disable, L=1=Enable)

Enable all devices: 

Access programming mode

 → 

Enable particular device:  

Access programming mode

 →         

U

Enable Arming status:

Disable Arming status:

Standby Mode

Standby Mode

Enter Program Mode

Card only

Card only

Card or Passcode

Card or Passcode

Card and Passcode

Card and Passcode

※ 

Factory default armingcode is: 1234. U=Reader unit (0=ECL-ACC997 / ECl-ACC999, 1=WG Reader).

F. Setting Up the Arming

Conditions:

1. Arming is enabled
2.Alarm system connected

Application:
1. Door open too long

: Door is open longer than door relay time plus door close time.

2. Force open

 (Opened without a valid user card): Access by force or illegal procedure.

3. Door position abnormal

: Arming is enabled and the power is suddenly off then on.

Enable all devices

Induct valid card

 →

 Input 4 digit 

arming code

 →

Enable particular device

Induct valid card 

 Input 4 digit 

arming code 

     U      or

Disable particular device

Induct valid card 

 Input 4 digit 

arming code 

      U      or

Input 5 digit user address

 →

 Input 4 

digit pass code

 →      →

 Input 4 digits 

arming code

 →

or        U

Induct valid card

 

 Input 4 digit pass 

code 

      

 Input 4 digits arming 

code

 

or        U

Disable all devices

Induct valid card

 →

 Input 4 digit 

arming code

 →

9

Input 5 digit user address

 →

 Input 4 

digit pass code

 →      →

 Input 4 digits 

arming code

 →

or         U

9

Induct valid card

 

 Input 4 digit pass 

code 

      

 Input 4 digits arming 

code

 

or         U

9

G. Adding / Deleting Fingerprint or Finger-Vein

H. Enable/Disable Skip Finger/Tag

Adding

How to add a finger data:

Access programming mode

 →

Place your finger on the sensor

[F=1= Adding 1 Finger data; F=2= Adding 2 Finger data; UUUUU= User address]

F

UUUUU

9

3

Deleting

UUUUU= User address 

Access programming mode

 →

0

UUUUU

9

3

Deleting All

Access programming mode

 →

9

99999

9

3

 

If you hear continuous "beep..." sounds when you place finger on the sensor, please release your finger from the sensor.

(Please consult detail command on page 8.)

 

Command Setting

 

Software Setting

 

Access Mode

 

Way

 40      1      NNNNN      EEEEE 

 40      3      NNNNN      EEEEE

     

Just fingerprint

      Just card control

 

FP first and then Tag

First

        

Then

  

 40      0      NNNNN      EEEEE

 40      2      NNNNN      EEEEE 

     

Just fingerprint

      Just card control

 

FP only or Tag only

Access programming mode

 → 

NNNNN

starting user address

EEEEE= ending user address

F

1+3(Default Value)

F

NNNNN       EEEEE

0

4

or

Adding

1 FingerVein

Finger

1

Bi

(release)

Finger

1

Bi

(Higher)

(release)

Finger

1

Bi

(Higher)

(release)

High pitch

Long Bi

(OK)

Adding

2 FingerVein

Finger

1

Bi

(release)

Finger

1

Bi

(Higher)

(release)

Finger

1

Bi

(Higher)

(release)

Long Bi

(OK)

Finger

2

Bi

(release)

Finger

2

Bi

(Higher)

(release)

Finger

2

Bi

(Higher)

(release)

High pitch

Long Bi

(OK)

Adding

1 Fingerprint

(By DO)

Finger

1

Bi

Di

Bi

Long Bi

(OK)

Adding

2 Fingerprint

(By DO)

Finger

1

Bi

Di

Bi

Long 

Bi

(OK)

Finger

2

Bi

Di

Bi

Long Bi

(OK)

Содержание ECL-ACC997

Страница 1: ...ED Output 5V 20mA Max 3 Brown Green LED Output 5V 20mA Max Door Output 4 Blue White Transistor Output Max 12V 100mA Open Collector Active Low Wiegand 5 Thin Green Wiegand DAT 0 Input 6 Thin Blue Wiega...

Страница 2: ...ontroller RTE RTE RTE RTE RTE POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC POWER 12VDC Magnet Lock Connect to Ele...

Страница 3: ...C997 ACL ACC999 set to exit reader WG Reader set to access reader Access programming mode 20 0 128 20 1 192 Please refer to function default value for details Enable Disable auto open zone Access prog...

Страница 4: ...digit arming code Enable particular device Induct valid card Input 4 digit arming code U or Disable particular device Induct valid card Input 4 digit arming code U or Input 5 digit user address Input...

Страница 5: ...n where finger can easily be placed 2 Use the middle or ring finger of either hand for the registration authentication purpose 3 Put your finger tip first to the top of the unit and lower the finger d...

Страница 6: ...sticker on Ethernet Module device Please revise IP address you want and then click Update button After updating the IP please re connect the Web Browser by new IP address User Password The password c...

Страница 7: ...r code settings 09 PPPPPPRRRRRR PPPPPP New master code RRRRRR Repeat the new master code Suspend or delete tags Suspend 10 SSSSS EEEEE Suspend Delete SSSSS starting user address EEEEE ending user addr...

Страница 8: ...99 En Disable Skip Finger Tag 40 F NNNNN EEEEE First 40 1 NNNNN EEEEE Then 40 3 NNNNN EEEEE Function Default Value 20 U DDD Default Value Function Option Value Application Time Attendance 0 Yes 1 No 0...

Отзывы: