V121203
Fingerprint & Finger Vein
Biometrics Device Access controller
E. Lift control
Single floor
[e.g.] User address NO. 45 only can reach the elevator to the 24th floor:
27 00045 24
Access programming mode
→
27 UUUUU LL
UUUU=User Address LL=Floor number (01~64 floor)
Connect with
Lift Controller
to control floors which the user will be able to access. [BAUD9600]
Set
(G)
Floor
L
8
16
24
32
40
48
56
64
0
1
2
3
4
5
6
7
L
6
14
22
30
38
46
54
62
L
7
15
23
31
39
47
55
63
L
5
13
21
29
37
45
53
61
L
4
12
20
28
36
44
52
60
L
3
11
19
27
35
43
51
59
L
2
10
18
26
34
42
50
58
L
1
9
17
25
33
41
49
57
Please refer to below floor chart
[e.g.] User address NO. 168 can reach only the 6th and 20th floor:
Access programming mode
→
21 00168 0 00100000
→
21 00168 2 00001000
→
OK (Please refer to floor chart as right.)
Multi floors
Access programming mode
→
21 UUUUU G LLLLLLLL
[UUUUU=User address G: 8 sets of lift control (Input: 0~7) LLLLLLLL:
8 floors setting (L=0=Disable, L=1=Enable)
Enable all devices:
Access programming mode
→
Enable particular device:
Access programming mode
→
U
Enable Arming status:
Disable Arming status:
Standby Mode
Standby Mode
Enter Program Mode
Card only
Card only
Card or Passcode
Card or Passcode
Card and Passcode
Card and Passcode
※
Factory default armingcode is: 1234. U=Reader unit (0=ECL-ACC997 / ECl-ACC999, 1=WG Reader).
F. Setting Up the Arming
Conditions:
1. Arming is enabled
2.Alarm system connected
Application:
1. Door open too long
: Door is open longer than door relay time plus door close time.
2. Force open
(Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal
: Arming is enabled and the power is suddenly off then on.
Enable all devices
Induct valid card
→
Input 4 digit
arming code
→
Enable particular device
Induct valid card
→
Input 4 digit
arming code
→
U or
Disable particular device
Induct valid card
→
Input 4 digit
arming code
→
U or
Input 5 digit user address
→
Input 4
digit pass code
→ →
Input 4 digits
arming code
→
or U
Induct valid card
→
Input 4 digit pass
code
→
→
Input 4 digits arming
code
→
or U
Disable all devices
Induct valid card
→
Input 4 digit
arming code
→
9
Input 5 digit user address
→
Input 4
digit pass code
→ →
Input 4 digits
arming code
→
or U
9
Induct valid card
→
Input 4 digit pass
code
→
→
Input 4 digits arming
code
→
or U
9
G. Adding / Deleting Fingerprint or Finger-Vein
H. Enable/Disable Skip Finger/Tag
Adding
How to add a finger data:
Access programming mode
→
Place your finger on the sensor
[F=1= Adding 1 Finger data; F=2= Adding 2 Finger data; UUUUU= User address]
F
UUUUU
9
3
Deleting
UUUUU= User address
Access programming mode
→
0
UUUUU
9
3
Deleting All
Access programming mode
→
9
99999
9
3
※
If you hear continuous "beep..." sounds when you place finger on the sensor, please release your finger from the sensor.
(Please consult detail command on page 8.)
Command Setting
Software Setting
Access Mode
Way
40 1 NNNNN EEEEE
40 3 NNNNN EEEEE
Just fingerprint
Just card control
FP first and then Tag
First
Then
40 0 NNNNN EEEEE
40 2 NNNNN EEEEE
Just fingerprint
Just card control
FP only or Tag only
Access programming mode
→
NNNNN
=
starting user address
EEEEE= ending user address
F
=
1+3(Default Value)
F
NNNNN EEEEE
0
4
or
Adding
1 FingerVein
Finger
1
Bi
(release)
Finger
1
Bi
(Higher)
(release)
Finger
1
Bi
(Higher)
(release)
High pitch
Long Bi
(OK)
Adding
2 FingerVein
Finger
1
Bi
(release)
Finger
1
Bi
(Higher)
(release)
Finger
1
Bi
(Higher)
(release)
Long Bi
(OK)
Finger
2
Bi
(release)
Finger
2
Bi
(Higher)
(release)
Finger
2
Bi
(Higher)
(release)
High pitch
Long Bi
(OK)
Adding
1 Fingerprint
(By DO)
Finger
1
Bi
Di
Bi
Long Bi
(OK)
Adding
2 Fingerprint
(By DO)
Finger
1
Bi
Di
Bi
Long
Bi
(OK)
Finger
2
Bi
Di
Bi
Long Bi
(OK)