background image

 

 

 

 

 
 
 
 
 
 
 

Operating Instructions 

 

 

Boilermag XL 

Filter 

 

High Intensity Magnetic Separator 

 

 
 
 
 
 
 
 
 
 

Technical data is subject to change without 

notice due to technical innovation! 

 
 

Eclipse Magnetics Ltd 

Atlas Way, Atlas North, Sheffield, S4-7QQ, England 

Tel: ++44 (0)114 225 0600 Fax: ++44 (0)114 2250525 

[email protected]

 

www.eclipsemagnetics.com

 

 

 

20130531 

 

 

Содержание Boilermag XL

Страница 1: ...Separator Technical data is subject to change without notice due to technical innovation Eclipse Magnetics Ltd Atlas Way Atlas North Sheffield S4 7QQ England Tel 44 0 114 225 0600 Fax 44 0 114 2250525...

Страница 2: ...res 8 4 3 Dangers during neglect of the safety notes 8 4 4 Safety notes for operation and maintenance 8 4 5 Notes on residual risks 9 4 6 Consequences with arbitrary change 9 4 7 Prohibited operation...

Страница 3: ...magnetic and paramagnetic particles are removed before they can cause any expensive damage For further information relating to the standard benefits and operation please refer to the downloadable Boi...

Страница 4: ...4 1 4 Overview of Boilermag XL Magnet Core Assembly Filter Body Details of magnetic circuits showing open flow path through bowl even when core is fully contaminated...

Страница 5: ...5 Magnet Core Assembly Filter Body...

Страница 6: ...ar Vessel Construction Stainless steel Magnetic Material NdFeB N42SH Port size 1 1 2 BSP Port size Optional 1 1 2 NPT Contamination capacity 1kg Vessel Volume 1 4 Litres Vessel Weight 5 4 kg 2 2 Noise...

Страница 7: ...ousing and forms one unit e g fitted in series with the pipe line The flow is arranged in such a manner that the material that is to be cleaned is well distributed and comes intensively into contact w...

Страница 8: ...n a manner not intended can present safety hazards 4 4 Safety notes for operation and maintenance Maintenance work is to be executed only by qualified personnel With work on pneumatic hydraulic pressu...

Страница 9: ...the bowl prior to cleaning It is recommended that Boilermag XL is installed on the return line of the heating system just prior to the boiler If the Boilermag XL is to be installed using flexible hos...

Страница 10: ...ol provided unscrew and remove M8 Domed nuts Washers Lift the Magnet Cartridge Assembly out of the body and move it away to a cleaning station Non magnetic contamination will remain in the bottom of t...

Страница 11: ...11 Remove Core from Body Dismantling Instructions Loosen Drain Plug using Tool Provided Remove Drain Plug...

Страница 12: ...12 Rotate Mesh Plate Counter Clockwise Remove Mesh Plate Before cleaning Magnet Core Dismantling Cleaning Mesh Instructions...

Страница 13: ...13 Cleaning Magnet Core Instructions Scrape Contamination in a downwards movement using Tool Provided...

Страница 14: ...ossible damage to the system It is strongly recommended that regular inspections are carried out to check for moisture and that appropriate action is taken to ensure the bar magnets are dried thorough...

Страница 15: ...onal air fright transmissions are to be packed accordingly in wooden boxes or in export packaging You have to ensure that the maximum values of magnetic field strength are not exceeded when sending by...

Страница 16: ...move handling safeguards once all installation work has been completed When handling in a loading area make sure the unit cannot topple over or slip Damage caused during transportation must always be...

Отзывы: