Notes on residual risks
Vent any trapped pressure from the process line prior to working on the unit.
4.6 Consequences with arbitrary change
With arbitrary change or repairs all warranties and assertions delivered by the manufacturer become
void.
Only genuine o.e.m. parts are to be used in any repair to maintain the
manufacturer’s
warranty.
4.7 Prohibited operation
The unit must not be subjected to any high external loads or induced vibrations.
5
Installation / Operation
5.1 Mechanical installation
For optimum performance the unit is to be installed as follows:
Before installation ensure that all supplies are isolated.
Boilermag XL is to be installed vertically with the bowl pointing downwards; this allows fluid to
drain out of the bowl prior to cleaning.
It is recommended that Boilermag XL is installed on the return line of the heating system just
prior to the boiler.
If the Boilermag XL is to be installed using flexible hoses, please ensure the unit is suitably
supported.
The function of the magnetic core ‘cartridge’ is direction specific. When installing please
ensure the mesh segment is on the outlet side of the pipework.
If the system is subject to pressure surges install a pressure regulator set at 6bar prior to the
Boilermag XL.
o
Seal mating piping joints effectively to reduce pressure/product loss
o
Erect signage in the close proximity warning of hazards presented by permanent
magnets, ie pace makers and the dangers of opening the magnet housing whilst
product is flowing.
o
Install in location with adequate free space to withdraw magnet cartridge from vessel
for cleaning
o
Consider manual handling regulations when deciding installation location