background image

 

 

5.3. Remote Control GPO Ports 

WPaBT has 1 NO/NC (normally open/normally closed) relay output on its rear panel. This 

output’s  change  of  status  is  associated  with  the 

detection  of  active  A2DP  audio 

connections. This makes it possible for it to interact with external equipment, such as 
motors for projection screens or movable partitions, lights, sirens, GPI inputs from other 
equipment, etc. 

5.4. eMCONTROL1 connection 

WPaBT can provide a remote audio input for a HUB device, using it in combination with 
eMCONTROL1.  Additionally,  an  external  power  supply  is  not  required,  as  power  is 
supplied by the HUB device via eMCONTROL1.  

 

Figure 2: WPaBT + eMCONTROL1 connection diagram 

Note: 

Either LEFT or RIGHT outputs can be connected. Ensure that the output is set to 

mono using the Ecler Bluetooth® Manager configuration application. 

 

 

Содержание WPaBT

Страница 1: ...v 20200623 WPaBT REMOTE CONTROLS AND INTERFACES Bluetooth Receiver Wall Panel USER MANUAL ...

Страница 2: ...6 5 3 Remote Control GPO Ports 7 5 4 eMCONTROL1 connection 7 INSTALLATION 9 6 1 Installation of a single unit on the surface or flush 9 6 2 Installation of a WPaBT unit together with an eMCONTROL1 control panel on the surface or flush 9 CONNECTION TO PC 10 CONFIGURATION 12 OPERATION 14 DIAGRAM OF FEATURES 15 TECHNICAL CHARACTERISTICS 16 MOUNTING DIAGRAM 17 PACKAGE CONTENTS 18 ...

Страница 3: ...sk of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not expose this equipment to rain or moisture WARNING An apparatus with Class I construction shall be connected to a mains socket outlet with a protective earthing connection IMPORTANT SAFETY INSTRUCTION...

Страница 4: ...done by unplugging the power cable from the mains input socket For this reason it always shall remain easily accessible 15 Equipment is connected to a socket outlet with earthing connection by means of a power cord 16 The marking information is located at the bottom of the unit 17 The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shal...

Страница 5: ... standard UE Bluetooth class 1 range 25m version V5 0 A2DP profile Balanced stereo Euroblock output dual mono configurable PAIR button with blue LED activity indicator This can be turned off in dark rooms so as not to disturb Easy device name configuration PIN stereo mono output and other adjustments via the Ecler Bluetooth Manager application for Windows devices External 24VDC power supply WP24 P...

Страница 6: ... radiation sources or high voltage cables such as power supply cables light cables or similar 5 2 Output audio connections WPaBT has 2 balanced audio outputs left and right with 3 pin Euroblock connectors in the following layout Hot or direct signal Terminal Cold or inverted signal Terminal Ground Terminal When connecting an output channel to an amplifier or audio device with a balanced input the ...

Страница 7: ... screens or movable partitions lights sirens GPI inputs from other equipment etc 5 4 eMCONTROL1 connection WPaBT can provide a remote audio input for a HUB device using it in combination with eMCONTROL1 Additionally an external power supply is not required as power is supplied by the HUB device via eMCONTROL1 Figure 2 WPaBT eMCONTROL1 connection diagram Note Either LEFT or RIGHT outputs can be con...

Страница 8: ...ectly but noise may appear on top of the signal that is input to WPaBT The solution to this problem is to use an external 24VDC power supply to power the eMCONTROL1 digital control it is recommended to use the Ecler WP24 PSU power supply unit The digital data connection between the HUB unit and the eMCONTROL1 unit has been successfully tested with a wiring distance of 600 meters using an external ...

Страница 9: ...uble box is required in order to mount both devices flush next to each other or a WPa2SMBOX double box is required for surface mounting Both WPa2FMBOX and WPa2SMBOX are sold separately 1 Remove the front panel covers from both devices WPaBT and eMCONTROL1 which are held in place by magnets You can use the magnet provided as a tool touching it to the upper right corner of the front cover and pullin...

Страница 10: ...vice to one of the USB ports of your computer Windows using a USB C to USB A cable Note Only applicable to units with serial numbers 001 to 100 4 Download and run the Ecler Bluetooth Manager application The latest available version of the firmware is provided with the application DOWNLOAD LINK Note configuration application available only for Windows 5 Select the corresponding COM port Note If the...

Страница 11: ...11 6 If the connection is successfully established a success message will be displayed on the screen Press OK to continue ...

Страница 12: ...esponds to the commercial name of the detected device VERSION indicates the current version of the device s firmware NAME name under which it appears on other Bluetooth devices By default this is Ecler WPaBT This name can be modified in order to be easily identifiable by a user PIN 4 digit numeric PIN password for pairing the device To add a level of security an access PIN can be set Note by defau...

Страница 13: ...ther new or old device that has already been paired will need to be paired again GPO TYPE GPO contact closure setting Normally open or Normally closed The contact closure will switch when there is an active A2DP audio connection Useful for establishing priorities or automation with other devices RESTORE CTRL if selected this allows you to reset all the settings of the device to factory defaults by...

Страница 14: ...o the waiting for connection state 3 Connected once the devices are paired when the connection is established the LED will light up continuously If the connection to the device is lost it will return to the waiting for connection state In addition the pairing button allows you to 4 Disable Enable LED If this feature is enabled you can disable enable the LED when the device is in waiting for connec...

Страница 15: ...15 DIAGRAM OF FEATURES 5 Power supply 6 Audio R 7 Audio L 8 GPO 1 Front panel cover 2 Bluetooth Antenna 3 PAIR button 4 USB C configuration port ...

Страница 16: ...PO Bidirectional Configurable NO NC vía Ecler Bluetooth Manager Pair button Front push button Pair LED Front LED BLUE color Programing and control ECLER BLUETOOTH MANAGER via USB C Physical Type Bluetooth Receiver Format Double Gang EU Format Installation options Surface In wall Certifications Enclosure material Zincor front panel plastic frame Operating temperature Min 0 C 32 F Max 35 C 95 F Oper...

Страница 17: ...17 MOUNTING DIAGRAM ATTENTION The frame s magnets C exert considerable force Assemble parts A and B carefully in order to avoid damaging the coating on frame C A C B ...

Страница 18: ... mounting in single unit systems Cover Magnet for cover removal Euroblock terminals for power audio and GPO connections Surface box Screws for attachment to surface box or to optional mounting boxes WPa2FMBOX and WPa2SMBOX Warranty card ...

Страница 19: ...ake changes or improvements to the design or manufacture of the product that may affect its specifications For technical inquiries please contact your supplier distributor or fill in the contact form on our website under Support Technical Inquiries Motors 166 168 08038 Barcelona Spain 34 932238403 information ecler com www ecler com ...

Отзывы: