Ecler MIM088SG Скачать руководство пользователя страница 5

 

 

NEEC AUDIO BARCELONA, S.L. 

accepts no liability for any damage that may be caused 

to people, animal or objects due to failure to comply with the warnings above. 

 

IMPORTANT NOTE 

Thank you for choosing our Ecler 

MIMO88SG / 1212SG Installation Digital Matrix

It  is 

VERY  IMPORTANT

  to  carefully  read  this  manual  and  to  fully  understand  its 

contents  before  any  connection  in  order  to  maximize  your  use  and  get  the  best 
performance from this equipment. 

To ensure optimal operation of this device, we strongly recommend that its maintenance 
be carried out by our authorised Technical Services. 

All ECLER products are covered by warranty

, please refer to 

www.ecler.com

 or the 

warranty card included with this product for the period of validity and conditions. 

 

INTRODUCTION 

The MIMO SG is a series of fully programmable digital audio matrixes, with the following 
features: 

 

8  (MIMO88SG)  or  12  (MIMO1212SG)  balanced  MIC/LINE  inputs  (independent 
phantom power per input channel). 

 

8 (MIMO88SG) or 12 (MIMO1212SG) balanced LINE outputs. 

 

8 (MIMO88SG) or 12 (MIMO1212SG) GPI control ports (

General Purpose Input

). 

 

Programming and remote management via Ethernet using EclerNet Manager (or 
point to point, with a direct CAT5 cable, or from an Ethernet network). 

 

Remote  control  via  UCP  (User  Control  Panel)  clients  on  Ethernet:  simultaneous 
clients with customized control panel, such as WPNETTOUCH Ecler, Android®, 
iOS®, Windows®, etc. 

 

Remote control from third party external devices. (Crestron, AMX, Vity, Medialon, 
etc. Registered trademarks of their manufacturers). TP-NET protocol, via Ethernet 
or RS-232 ports. 

 

Remote control bus for WPNETTOUCH digital panels and MPAGE16 messaging 
consoles (

paging

). 

 

Configuration memory (

presets

) management. 

 

Scheduled events based on calendar. 

 

WPNET4KV  and  WPNET8K  compatible  control  panels  (using  specific  retro-
compatible Firmware

*

). 

*

 For more information see 

WPNET4KV

 and 

WPNET8K

 user's manual. 

 

Extensive DSP available: 

Содержание MIM088SG

Страница 1: ...50 0317 0107 MIMO88SG 1212SG EN MIMO88SG 1212SG DIGITAL MATRIXES Installation Digital Matrix USER MANUAL...

Страница 2: ...Ports 10 5 8 Remote control RS 232 Port 11 5 9 Front panel controls and LED indicators 11 CLEANING 11 FUNCTION LIST 12 FUNCTION DIAGRAMS 13 8 1 MIMO88SG 13 8 2 MIMO1212SG 14 TECHNICAL CHARACTERISTICS...

Страница 3: ...k of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not...

Страница 4: ...stopped but fully disconnecting the device from mains is done by unplugging the power cable from the mains input socket For this reason it always shall remain easily accessible 15 Equipment is connec...

Страница 5: ...owing features 8 MIMO88SG or 12 MIMO1212SG balanced MIC LINE inputs independent phantom power per input channel 8 MIMO88SG or 12 MIMO1212SG balanced LINE outputs 8 MIMO88SG or 12 MIMO1212SG GPI contro...

Страница 6: ...ompatible with the MIMO88SG MIMO1212SG hardware which can be freely updated with anyone of them The MIMO SG programming is done with EclerNet Manager Please refer to EclerNet Manager Software manual a...

Страница 7: ...nit offers 8 MIMO88SG or 12 MIMO1212SG balanced analogue signal inputs IN accepting both line and microphone level signals Input signal type selection and management are carried out from EclerNet Mana...

Страница 8: ...8 Ground Terminal For UNBALANCED connections leave the terminal unconnected...

Страница 9: ...1 Factory Preset Network settings The factory default network settings for EclerNet Manager compatible devices are as follows IP 192 168 0 100 Mask 255 255 255 0 Gate 192 168 0 1 UDP Port 2210 5 6 RE...

Страница 10: ...onnectors are screw terminal blocks with three contacts The wiring is as follows Positive 12 VDC Pin Variable voltage 0 12 VDC Pin Ground Pin WPaVOL connection to MIMO serial GPI ports WPaVOL SR conne...

Страница 11: ...order the increased intensity level Output LED indicators indicate the presence of audio signal at the unit s output and its intensity level green amber and red indicate in this order the increased in...

Страница 12: ...tor POWER 5 Signal output screw terminal OUT 6 Signal input screw terminal IN 7 RJ 45 connector ETHERNET 8 Screw terminals for digital remote control REMOTE 9 Screw assembled remote control terminals...

Страница 13: ...13 FUNCTION DIAGRAMS 8 1 MIMO88SG 1 1 5 6 7 8 9 1 1 1 2 3 2 3 4 0 1...

Страница 14: ...14 8 2 MIMO1212SG...

Страница 15: ...tness better than 0 1dB THD Noise 1kHz 0dBV input line 0 004 THD Noise 1kHz 40dBV input mic 0 008 Output Noise floor FFT 20Hz 20kHz better than 115dB Interchannel crosstalk 20Hz 20kHz better than 90dB...

Страница 16: ...om 10 ms to 1000 ms Make up gain from 0 to 10 dB Input Frequency Shifter x4 Feedback Loop Reducer Available on IN1 to IN4 ON OFF function Output Limiter x8 Bypass On Off Threshold from 36 dBV to 18 dB...

Страница 17: ...rs Resolution 24bit AKM Dynamic Range AD 110dB DA 115dB Analogue 12 Input Output Terminal block Symmetrical Analogue Input headroom 27dBV 30dBu Max output level 18dBV 21dBu Input sensitivity 0dBV out...

Страница 18: ...80 dB Attack time from 0 1 ms to 500 ms Hold time from 10 ms to 3000 ms Release time from 10 ms to 1000 ms Input Compressor Limiter x12 Bypass On Off Threshold from 36 dBV to 18 dBV Ratio 1 1 to inf...

Страница 19: ...Weight 3 2kg Supply Mains 90 264VCA 47 63Hz Power consumption 75VA Miscellaneous Management Connectivity Ethernet Base Tx 10 100Mb Auto X Over CAT5 up to 100m Remote Bus Over twisted pairs up to 1km s...

Страница 20: ...20 BLOCK DIAGRAMS 10 1 MIMO88SG...

Страница 21: ...21 10 2 MIMO1212SG...

Страница 22: ...22 TP NET PROTOCOL SOFTWARE Third Party NET USER MANUAL...

Страница 23: ...fixed no autonegotiation for all the devices except for DUO NET PLAYER eMIMO1616 HUB series and MIMO4040CDN which use 115200 baud rate Data bits 8 Parity None Stop bits 1 Flow control None In case th...

Страница 24: ...essage that is sent from the EclerNet device when the initial message from the client to the device was SYSTEM CONNECT PINGPONG The communication using UDP or RS 232 starts when a client sends the mes...

Страница 25: ...vel Pre Vumeter Level y Post Vumeter Level are numerical values in the 0 100 range that define values in a scale equivalent to inf 0 dB GPI GPO are numerical values within the 1 8 range for the MIMO88...

Страница 26: ...rrent device status with DATA messages DISCONNECT Cancel subscriptions and terminates communication SUBSCRIPTION_RATE Rate Alive message from device PING Alive message from device PONG Alive ACK messa...

Страница 27: ...alue of an Output Channel GPI Input Gets the current value of a General Purpose Input GPO Output Gets the current value of a General Purpose Output not valid for MIMO88SG MIMO1212SG INFO_NAME Gets the...

Страница 28: ...GPO Value Sets the current value for a General Purpose Output not valid for MIMO88SG VIRTUAL_CONTROL Virtual Control Value Sets the Virtual Control value Value can range from 1 to 100 INC ILEVEL Input...

Страница 29: ...utput Channel VU meter UNSUBSCRIBE ALL Unsubscribe to all VU meters IVU Input Channel Unsubscribe to an Input Channel VU meter OVU Output Channel Unsubscribe to an Output Channel VU meter Note INC and...

Страница 30: ...tus for a Matrix Point VIRTUAL_CONTROL Virtual Control Value Shows the Virtual Control value Value can range from 1 to 100 IVU Input Channel Pre Vumeter Level Post Vumeter Level Shows the VU meter val...

Страница 31: ...current status of the AUTOMIXER function for inputs 1 to 8 SUBSCRIBE GATE Subscribes to the status of the NOISE GATE for inputs 1 to 8 AUTOMIXER Subscribes to the status of the AUTOMIXER function for...

Страница 32: ...MIMO1212SG MIMO88SG CONFERENCE MIMO1212SG CONFERENCE SERIES SPECIFIC ERROR CODES ERROR ID DESCRIPTION 6 UDP_ERROR_TIMEOUT_PONG 7 UDP_ERROR_CONNECT_WHILE_CONNECTED 8 UDP_ERROR_DISCONNECT_WHILE_UNCONNE...

Страница 33: ...ht to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on o...

Отзывы: