Ecler MIM088SG Скачать руководство пользователя страница 4

 

 

 

9.

 

Do  not  defeat  the  safety  purpose  of  the  polarized  or  grounding  type  plug.  A 
polarized plug has two blades with one wider than the other. A grounding type 
plug has two blades and a third grounding prong. The wide blade or the third 
prong  are  provided  for  your  safety.  If  the  provided  plug  does  not  fit  into  your 
outlet, consult an electrician for replacement of the obsolete outlet. 

10.

 

Protect the power cord from being walked on or pinched particularly at the plugs, 
convenience receptacles, and at the point where they exit from the apparatus. 

11.

 

Only use attachments/accessories specified by the manufacturer. 

12.

 

Unplug the apparatus during lightening sorts or when unused for long periods of 
time. 

13.

 

Refer  all  servicing  to  qualified  personnel.  Servicing  is  required  when  the 
apparatus has been damaged in any way, such as power supply cord or plug is 
damaged, liquid has been spilled or objects have fallen into the apparatus, the 
apparatus has been exposed to rain or moisture, does not operate normally, or 
has been dropped.

 

14.

 

Disconnecting  from  mains:  When  switching  off  the  POWER  switch,  all  the 
functions and light indicators of the unit will be stopped, but fully disconnecting 
the device from mains is done by unplugging the power cable from the mains 
input socket. For this reason, it always shall remain easily accessible. 

15.

 

Equipment is connected to a socket-outlet with earthing connection by means of 
a power cord. 

16.

 

The marking information is located at the bottom of the unit. 

17.

 

The apparatus shall not be exposed to dripping or splashing and that no objects 
filled with liquids, such as vases, shall be placed on apparatus. 

18.

 

This product is for indoor use only. 

 

NOTE: 

This equipment has been tested and found to comply with the limits for a Class 

A  digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to 
provide  reasonable  protection  against  harmful  interference  when  the  equipment  is 
operated in a commercial environment. This equipment generates, uses, and can radiate 
radio frequency energy and, if not installed and used in accordance with the instruction 
manual,  may  cause  harmful  interference  to  radio  communications.  Operation  of  this 
equipment in a residential area is likely to cause harmful interference in which case the 
user will be required to correct the interference at his own expense. 

WARNING

:

 

This product must not be discarded, under any circumstance, as 

unsorted  urban  waste.  Take  to  the  nearest  electrical  and  electronic  waste 
treatment centre. 

Содержание MIM088SG

Страница 1: ...50 0317 0107 MIMO88SG 1212SG EN MIMO88SG 1212SG DIGITAL MATRIXES Installation Digital Matrix USER MANUAL...

Страница 2: ...Ports 10 5 8 Remote control RS 232 Port 11 5 9 Front panel controls and LED indicators 11 CLEANING 11 FUNCTION LIST 12 FUNCTION DIAGRAMS 13 8 1 MIMO88SG 13 8 2 MIMO1212SG 14 TECHNICAL CHARACTERISTICS...

Страница 3: ...k of electric shock The external wiring connected to the terminals requires installation by an instructed person or the use of ready made leads or cords WARNING To prevent fire or shock hazard do not...

Страница 4: ...stopped but fully disconnecting the device from mains is done by unplugging the power cable from the mains input socket For this reason it always shall remain easily accessible 15 Equipment is connec...

Страница 5: ...owing features 8 MIMO88SG or 12 MIMO1212SG balanced MIC LINE inputs independent phantom power per input channel 8 MIMO88SG or 12 MIMO1212SG balanced LINE outputs 8 MIMO88SG or 12 MIMO1212SG GPI contro...

Страница 6: ...ompatible with the MIMO88SG MIMO1212SG hardware which can be freely updated with anyone of them The MIMO SG programming is done with EclerNet Manager Please refer to EclerNet Manager Software manual a...

Страница 7: ...nit offers 8 MIMO88SG or 12 MIMO1212SG balanced analogue signal inputs IN accepting both line and microphone level signals Input signal type selection and management are carried out from EclerNet Mana...

Страница 8: ...8 Ground Terminal For UNBALANCED connections leave the terminal unconnected...

Страница 9: ...1 Factory Preset Network settings The factory default network settings for EclerNet Manager compatible devices are as follows IP 192 168 0 100 Mask 255 255 255 0 Gate 192 168 0 1 UDP Port 2210 5 6 RE...

Страница 10: ...onnectors are screw terminal blocks with three contacts The wiring is as follows Positive 12 VDC Pin Variable voltage 0 12 VDC Pin Ground Pin WPaVOL connection to MIMO serial GPI ports WPaVOL SR conne...

Страница 11: ...order the increased intensity level Output LED indicators indicate the presence of audio signal at the unit s output and its intensity level green amber and red indicate in this order the increased in...

Страница 12: ...tor POWER 5 Signal output screw terminal OUT 6 Signal input screw terminal IN 7 RJ 45 connector ETHERNET 8 Screw terminals for digital remote control REMOTE 9 Screw assembled remote control terminals...

Страница 13: ...13 FUNCTION DIAGRAMS 8 1 MIMO88SG 1 1 5 6 7 8 9 1 1 1 2 3 2 3 4 0 1...

Страница 14: ...14 8 2 MIMO1212SG...

Страница 15: ...tness better than 0 1dB THD Noise 1kHz 0dBV input line 0 004 THD Noise 1kHz 40dBV input mic 0 008 Output Noise floor FFT 20Hz 20kHz better than 115dB Interchannel crosstalk 20Hz 20kHz better than 90dB...

Страница 16: ...om 10 ms to 1000 ms Make up gain from 0 to 10 dB Input Frequency Shifter x4 Feedback Loop Reducer Available on IN1 to IN4 ON OFF function Output Limiter x8 Bypass On Off Threshold from 36 dBV to 18 dB...

Страница 17: ...rs Resolution 24bit AKM Dynamic Range AD 110dB DA 115dB Analogue 12 Input Output Terminal block Symmetrical Analogue Input headroom 27dBV 30dBu Max output level 18dBV 21dBu Input sensitivity 0dBV out...

Страница 18: ...80 dB Attack time from 0 1 ms to 500 ms Hold time from 10 ms to 3000 ms Release time from 10 ms to 1000 ms Input Compressor Limiter x12 Bypass On Off Threshold from 36 dBV to 18 dBV Ratio 1 1 to inf...

Страница 19: ...Weight 3 2kg Supply Mains 90 264VCA 47 63Hz Power consumption 75VA Miscellaneous Management Connectivity Ethernet Base Tx 10 100Mb Auto X Over CAT5 up to 100m Remote Bus Over twisted pairs up to 1km s...

Страница 20: ...20 BLOCK DIAGRAMS 10 1 MIMO88SG...

Страница 21: ...21 10 2 MIMO1212SG...

Страница 22: ...22 TP NET PROTOCOL SOFTWARE Third Party NET USER MANUAL...

Страница 23: ...fixed no autonegotiation for all the devices except for DUO NET PLAYER eMIMO1616 HUB series and MIMO4040CDN which use 115200 baud rate Data bits 8 Parity None Stop bits 1 Flow control None In case th...

Страница 24: ...essage that is sent from the EclerNet device when the initial message from the client to the device was SYSTEM CONNECT PINGPONG The communication using UDP or RS 232 starts when a client sends the mes...

Страница 25: ...vel Pre Vumeter Level y Post Vumeter Level are numerical values in the 0 100 range that define values in a scale equivalent to inf 0 dB GPI GPO are numerical values within the 1 8 range for the MIMO88...

Страница 26: ...rrent device status with DATA messages DISCONNECT Cancel subscriptions and terminates communication SUBSCRIPTION_RATE Rate Alive message from device PING Alive message from device PONG Alive ACK messa...

Страница 27: ...alue of an Output Channel GPI Input Gets the current value of a General Purpose Input GPO Output Gets the current value of a General Purpose Output not valid for MIMO88SG MIMO1212SG INFO_NAME Gets the...

Страница 28: ...GPO Value Sets the current value for a General Purpose Output not valid for MIMO88SG VIRTUAL_CONTROL Virtual Control Value Sets the Virtual Control value Value can range from 1 to 100 INC ILEVEL Input...

Страница 29: ...utput Channel VU meter UNSUBSCRIBE ALL Unsubscribe to all VU meters IVU Input Channel Unsubscribe to an Input Channel VU meter OVU Output Channel Unsubscribe to an Output Channel VU meter Note INC and...

Страница 30: ...tus for a Matrix Point VIRTUAL_CONTROL Virtual Control Value Shows the Virtual Control value Value can range from 1 to 100 IVU Input Channel Pre Vumeter Level Post Vumeter Level Shows the VU meter val...

Страница 31: ...current status of the AUTOMIXER function for inputs 1 to 8 SUBSCRIBE GATE Subscribes to the status of the NOISE GATE for inputs 1 to 8 AUTOMIXER Subscribes to the status of the AUTOMIXER function for...

Страница 32: ...MIMO1212SG MIMO88SG CONFERENCE MIMO1212SG CONFERENCE SERIES SPECIFIC ERROR CODES ERROR ID DESCRIPTION 6 UDP_ERROR_TIMEOUT_PONG 7 UDP_ERROR_CONNECT_WHILE_CONNECTED 8 UDP_ERROR_DISCONNECT_WHILE_UNCONNE...

Страница 33: ...ht to make changes or improvements in the design or manufacturing that may affect these product specifications For technical queries contact your supplier distributor or complete the contact form on o...

Отзывы: