6
•
1 headphone audio output for output zone MONITOR function, mini-jack connector
and front panel volume control
•
8 REMOTE ports for the connection of digital remote panels type eMCONTROL1,
with wall format RJ45 connectors on the rear panel
•
Ethernet interface with RJ45 connector, for programming and remote control of the
unit by means of integrated HANGAR web application (embedded web-server)
and/or TP-NET protocol for integration with third parties
•
DHCP (factory setting) and static IP modes
•
RS-232 interface with DB9 connector, for remote control of the unit via TP-NET
protocol for integration with third parties
•
MUTE port for muting one or more zone outputs by means of external potential-
free contact closure
•
Meter sets for displaying output signals (zones) from the front panel
•
SELECT / MUTE key for each zone output on the front panel
•
LCD display, CONTROL key (CTRL) and digital rotary control (
encoder
) for control
of the unit's zone outputs from the front panel
•
DATA (connection from external client devices) and ON indicators on the front panel
•
Processing available in inputs:
o
3-tone equalization adjustment via BASS-MID-TREBLE controls
o
Volume adjustment and MUTE control
o
Phase inversion
o
Stereo: Allows balanced audio inputs to be configured in stereo pairs.
Available on local inputs INPUT5-8 on HUB1616, INPUT3-6 on HUB1408
o
Frequency shifter
available for the microphone inputs: local inputs
INPUT5-8 on HUB1616, INPUT3-6 on HUB1408
o
Noise gate: available on local inputs INPUT5-8 on HUB1616, INPUT3-6
on HUB1408.
o
High-pass filter: with adjustable frequency available on local inputs
INPUT5-8 on HUB1616, INPUT3-6 on HUB1408
o
Audio over audio priority function, with 4 levels and volume control
independent from the 4 (from -40dB to +6dB): inputs 5 to 8 MIC/LINE on
HUB1616, inputs 3 to 6 on HUB1408, can attenuate (or totally mute) the
sound content present (program audio) in certain target areas, enabling
the broadcasting of emergency messages, warnings, etc. Each of the
above inputs can exercise this function with priority 1 (higher) or 4 (lower).
Priority function activation modes can be:
▪
DUCKER, by audio signal detection: when a valid signal is received
and as long as it persists in the input in question. Available on local
inputs 5 to 8 on HUB1616, local inputs 3 to 6 on HUB1408
Содержание HUB Series
Страница 1: ...v 20200408 HUB Series DIGITAL MATRIX Digital zoner with DSP USER MANUAL ...
Страница 26: ...26 FUNCTION DIAGRAM ...
Страница 27: ...27 BLOCKS DIAGRAM 9 1 HUB1408 ...
Страница 28: ...28 9 2 HUB1616 ...