12
Figure 5: WPaMIX-T and eMCONTROL1 mounting
5.5. Connections PAGER A, PAGER B and priority PAGER / DUCKER modules
In the local input section of the rear panel there are 2 connection ports called PAGER A
and PAGER B, whose audio inputs correspond internally to the INPUT 7 and INPUT 8
inputs (respectively) on the HUB1616, INPUT5 and INPUT6 on the HUB1408.
Figure 6: PAGER/DUCKER ports on HUB1616
The PAGER ports are used for point-to-point connection to eMPAGE-type call stations,
through which it is possible to carry out real-time voice call (
paging
) actions to exit areas
of the installation, using a priority module of the HUB unit that attenuates or completely
silences the sound content of the program existing in these areas at the time of the action.
A standard CAT5 cable (uncrossed) or higher, with RJ45 connector on both ends,
connects a calling station point to one of the unit's A or B ports, running through it the
station's remote DC power, control data and balanced audio picked up by the station's
microphone.
HUB1616
REMOTE
Ports
eMCONTROL1
RJ45 connector
CAT5
Pair of wall panels, where eMCONTROL1 (right) receives balanced audio from
its companion panel, WPaMIX-T (left)