When processing is completed the following screen is displayed showing the distance to the liquid level
computed by the method that was selected at the time when the data was previously saved which in this
example is the Automatic (Collar Count) method.
When the user wishes to apply a different method of analysis he can do so by pressing the Analysis Options
button to open the following screen:
Analysis Options
:
This screen presents the user with a list of alternative liquid level depth calculation methods.
The following section discusses the Automatic Collar and Liquid Level Analysis which is the method that is used
most commonly.