3. 

Remove the cover by inserting a small screwdriver under the white 

enclosures lip. Gently twist the screw driver and pull the cover away from 

the base.

4. Choose a mounting method. The RVS/RCS sensor can be mounted:

• 

With the integrated magnets to a steel T-bar ceiling frame or other 

metallic surface by placing the sensor on to the metal rail. 

• 

With screws and anchors (not provided) to a wall-board ceiling.

i. 

Use a pencil to mark the mounting base keyhole locations and 

remove the sensor.

ii. 

Using a drill, bore the two holes and insert the anchors.

iii. 

Install the screws, leaving them loose while you place the sensor.

iv. 

Tighten the screws.

• 

With the provided wire adapter straps to a soft ceiling tile. 

i. 

Mark the sensor mounting location on the 

ceiling tile with a pencil. Remove the ceiling tile 

from the T-bar frame.

ii. 

Insert the soft ceiling tile adapters through the 

pair of small holes beside both keyholes on the 

sensors mounting plate. 

iii. 

Poke the adapter tines through the ceiling tile, 

then bend each tine over in opposite directions for 

a secure fit.

iv. 

Replace the ceiling tile.

• 

With double sided tape or Velcro™, not provided. Cut two lengths of 

tape and remove the backing. Place on the mounting surface of the 

sensors back plate, pressing down. Remove the backing from the tapes 

other side and place the sensor on the ceiling surface, pressing firmly.

5.  Refer to the section titled

 Linking the Sensor to a Receiver

.

6.  Once linking is complete, replace the sensor cover. 

Ensure the cover is fully 

seated. 

If the cover is not firmly attached, it could obstruct the lens and 

adversely affect operation.

Lens Masking

Lens  mask  stickers  are  provided  in  the  packaging  for 

 

your convenience.

1. 

As needed, peel off the lens masks to fit the desired 

area to be blocked.

2.  Apply the mask gently to the section of the lens exterior 

to block the required area from occupancy sensing.

Linking the Sensor to a Receiver

This process requires the controller or receiver to be mounted, 

powered and within range of the sensor to be linked.

Lens Mask Applied

Wire Mounts

Содержание RVS-A-xW

Страница 1: ...te the cover must be fully seated for proper operation Resonate Vacancy Occupancy Sensor Description The RVS RCS also referred to as the sensor in this guide is a wireless energy harvesting sensor tha...

Страница 2: ...motion is detected the sensor will transmit an occupied telegram If no motion is detected within 100 seconds the sensor transmits a vacancy telegram 200 seconds total since the previous transmission T...

Страница 3: ...nts as hot moving air may cause the sensor to false trigger Leave at least 4 1 2 m minimum between air vents and the sensor NOTE Incandescent lights may cause false trips when turning on 1 Select a lo...

Страница 4: ...s mounting plate iii Poke the adapter tines through the ceiling tile then bend each tine over in opposite directions for a secure fit iv Replace the ceiling tile With double sided tape or Velcro not p...

Страница 5: ...small screwdriver as a lever and insert under the battery Gently twist the screwdriver so the battery pops out 3 Install or replace the battery with a new CR1632 coin cell battery insuring the positi...

Страница 6: ...ode press and hold the test button for 6 seconds The green LED will begin to blink 2 A quick press and release of the button at this point will allow you to select between test modes Pressing and rele...

Страница 7: ...o to step 2 2 Press and hold the test button again for 6 seconds to select PIR sensitivity adjust mode One of the LEDs will begin blinking based on the selected settings see the Sensitivity Adjust Tab...

Страница 8: ...8 733 0111 Fax 604 815 0078 Email info echoflexsolutions com www echoflexsolutions com Copyright 2015 2017 Echoflex Solutions Inc Specifications subject to change without notice Document 8DC 5543 Revi...