background image

Echoflex Installation Guide

Magnetic Contact Sensor

Magnetic Contact Sensor (MC-31)

 Page 12 of 12

Echoflex

Compliance

For complete regulatory compliance information, see the Echoflex Magnetic 
Contact Sensor datasheet at 

echoflexsolutions.com

.

FCC Compliance

Echoflex Magnetic Contact Sensor

(For any FCC matters):
Echoflex Solutions, Inc.
3031 Pleasant View Road
Middleton, WI 53562
+1 (608) 831-4116

echoflexsolutions.com

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any 
interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference when the equipment is operated in a commercial environment. This 
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used 
in accordance with the instruction manual, may cause harmful interference to radio 
communications. Any modifications or changes to this product not expressly approved by 
Electronic Theatre Controls, Inc. could void the user’s authority to operate the product. Operation 
of this equipment in a residential area is likely to cause harmful interference in which case the user 
will be required to correct the interference at his own expense.

Contains FCC ID: SZV-STM300U

ISED Compliance

This device contains a license-exempt transmitter/receiver that complies with Innovation, Science, 
and Economic Development Canada’s license-exempt RSSs. Operation is subject to the following 
two conditions:

1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired 

operation of the device.

Contains IC ID: 5713A-STM300U

Conformité ISDE

Cet appareil contient un émetteur/récepteur conforme aux CNR d'Innovation, Sciences et 
Développement économique Canada (ISDE) applicables aux appareils radio exempt de licence. 
Son fonctionnement est soumis aux deux conditions suivantes:

1. L'appareil ne doit pas produire d'interférences.
2. L'utilisateur de l'appareil doit accepter toute interférence, même si l'interférence est 

susceptible d'en compromettre le fonctionnement.

Contient ID IC: 5713A-STM300U

Содержание MC-31

Страница 1: ...ity applications that require control to power a room or setback temperature control devices The MC 31incorporates features that assist the installer to position the device without the need for signal...

Страница 2: ...ne of the two slots at the side and gently pry to remove the sensor from the mounting plate 2 Mount the mounting plate using two 6 screws 3 Snap the sensor back into place Mount the Magnet Orienting t...

Страница 3: ...refer to the related product documentation 2 Press the Teach button on the sensor once to send a message The blue LED blinks to confirm a successful transmission 3 Deactivate Link mode on the controll...

Страница 4: ...he Teach button and color LEDs are used to navigate the Tests and Settings Menu The intervals between blinks make it easy to distinguish between single double and triple blinks Exit and Start Over gre...

Страница 5: ...Teach button until the white LED blinks twice 2 Press and release the Teach button to cycle through the menu of color LEDs and stop when the blue LED blinks once 3 Press and hold the Teach button unti...

Страница 6: ...operation a green LED blinks to indicate a contact open event and a red LED blinks to indicate a contact close event The LED Display setting controls whether the operating mode LEDs are enabled or dis...

Страница 7: ...ice 2 Press and release the Teach button to cycle through the menu of color LEDs and stop when the blue LED double blinks 3 Press and hold the Teach button until the white LED blinks twice to select E...

Страница 8: ...LED blink code displays the current setting Press and release the Teach button to navigate the options 4 Press and hold the Teach button until the white LED blinks twice when the target indication di...

Страница 9: ...the green LED triple blinks 3 Press and hold the Teach button until the white LED blinks twice to select Heartbeat Messaging The green LED blink code displays the current setting Press and release the...

Страница 10: ...le through the menu of color LEDs and stop when the blue LED triple blinks 3 Press and hold the Teach button until the white LED blinks twice to select Energy Status Messaging The blue LED blink code...

Страница 11: ...3 Press and hold the Teach button until the white LED blinks twice to select Redundant Messaging The red LED blink code displays the current setting Press and release the Teach button to navigate the...

Страница 12: ...anual may cause harmful interference to radio communications Any modifications or changes to this product not expressly approved by Electronic Theatre Controls Inc could void the user s authority to o...

Отзывы: