![background image](http://html1.mh-extra.com/html/echo/minitech-pro/minitech-pro_instruction-manual_3904043007.webp)
7
Dry Cell Batteries
When the unit is switched on, the Power indicator light will light up GREEN if dry cells
are okay.
If Power indicator shows FLASHING RED when switched on, or changes to FLASHING
RED when in use, then the dry cells are running low and will need to be replaced
within approximately 8 hours.
If the power indicator shows SOLID RED the dry cells will need to be replaced straight
away.
If there is no Light when the unit is switched on, this normally indicates the dry cells
are completely discharged and should be replaced.
Replacement Parts
1002
MiniTech Pro®
105
Drycell
490-1020-01
MiniTech Pro® Carton
940-1014-01
MiniTech Pro® Instruction
101
Headset
104
Stubby Microphone
202/M
Microphone on 1.5 m lead
202/C
Microphone Cable Clip
103MEG
3m Extension Lead
910-1003-01
QR NeckLoop
Technical Specifications
Frequency response
65Hz - 6.5KHz
Maximum Gain
45 dB
Maximum power output
112 dB
Tone control
10 dB range 300Hz, 10dB range 5KHz
Microphone
Electret condenser
Power
2 x AA Drycell
Connections
3.5mm jack for mic/ line in, headset or
neckloop.
Operating Time with Headset
Up to 120 hours
*
Operating Time with NeckLoop
Up to 50 hours
*
Weight with drycell
101 grams
Dimensions with clip
85(H) x 55 (W) x 30 (D) mm
*NOTE -
Results can vary depending on battery type/ age/ capacity/ manufacturer and usage