background image

Use only DC 5V. Do not charge with a voltage higher 
than DC 5V - 2A. 

Keep oxygen outlet on the underside of the pitcher 
unobstructed.

Only use manufacturer certified replacement parts and 
charging cables.

Using the pitcher without water may cause electrode 
damage.

If non -water drinks are used, wash the pitcher with citric 
acid within 1 hour.

Only use water when cleaning the exterior of the pitcher. 
Other detergents/chemicals may cause the pitcher to be 
discolored or lose paint.

If the electrodes are completely dry or the product has 
not been used for one week or longer. Fill the pitcher 
with water and use after 20 minutes.

Only use filtered water (R.O. or distilled water) in 
hydration process. 

If the electrodes have calcium build up or are damaged, 
performance can be degraded.  Do not clean the interior 
of the pitcher with chemical detergent.

5

Safety Instructions

Please be sure to  follow these instructions to  prevent electric shock, fire, or 

explosion which  could  result in  personal injury or  product dam age

!

Содержание H2 Pitcher

Страница 1: ...Echo H2 Pitcher Owner s Manual ...

Страница 2: ...ctions 4 Parts 6 Charging Instructions 7 Display Information 8 How to Use 9 How to Clean 10 Troubleshooting 11 Product Specifications 13 Product Warranty 14 The fastest way to reach customer support is to email them at info synergyscience com 2 ...

Страница 3: ...n enriched water in 10 and 20 minute cycles Specialized casing keeps hydrogenated water pure and fresh after filtering Built in rechargeable battery allows the Echo H2 water Pitcher to be used anytime and anywhere Eco friendly made of tritan plastic which is bpa free 3 ...

Страница 4: ...re Allow children to operate or handle the pitcher Use carbonated beverages green tea or alcohol in the pitcher Use water above 140 F 60 C Move the pitcher during hydrogen generation Clean the interior of the pitcher with chemical detergent The electrode will be damaged Use excessive force if product falls is thrown or is dropped call Customer Care see page 2 4 Safety Instructions Please be sure t...

Страница 5: ...etergents chemicals may cause the pitcher to be discolored or lose paint If the electrodes are completely dry or the product has not been used for one week or longer Fill the pitcher with water and use after 20 minutes Only use filtered water R O or distilled water in hydration process If the electrodes have calcium build up or are damaged performance can be degraded Do not clean the interior of t...

Страница 6: ...Handle Water Container Controller Display Main Body Cover Battery Cover Oxygen Outlet Bottom View Side View Parts 6 ...

Страница 7: ...le charging If the battery display LED is Red the pitcher is charging if the LED Display is Green the pitcher is fully charged Use a charging adapter with 5V 2A or higher Hydrogen generation is more effective when pitcher is plugged in and or fully charged Charging For Outlet Charging Connect the C type USB cable to the outlet adapter and to the USB port of the pitcher 7 ...

Страница 8: ...Operation in low current or electrode dry condition Water container is empty Activate with warm water 140 F 60 C or less and use Fill the water container with water and use Display Information Hydrogen Water Button Start stop button 10 minute 20 minute cycle duration select Mute Unmute function End of Operation mute unmute indicator Press hydrogen water button 3 times to mute unmute end of operati...

Страница 9: ... procedures see page 10 Open the top cover and fill with filtered water R O or distilled 10 minute Cycle Press and hold the Hydrogen Water Button for 2 seconds and the BLUE LED will light up at the bottom Display will show 10 minutes After 10 minutes the Echo H2 Pitcher will turn off automatically 20 Minute Cycle For higher concentrations of hydrogen press the operating button twice and the GREEN ...

Страница 10: ...ode is activated Clean the inside with a soft cloth cotton swab or sponge If dust or dirt is not rem oved add som e water and gently swirl several tim es Extra Cleaning Tips For better cleaning use with the power cable connected Water that is rich in m inerals m ay have cloudy bubbles and less hydrogen bubbles If there are less hydrogen bubbles use the above cleaning m ode before use Water Contain...

Страница 11: ... continue to use the pitcher to stabilize page 9 10 LED is not illuminated Product is not charged Check battery and charge if needed Thick bubbles occur Electrodes are dry or not yet stabilized Wet electrodes with water Continue using the pitcher to stabilize Operate 2 or 3 times with warm water 140 F 60 C or less Low battery light blinks during hydrogen water generation Low Battery Charge the Ech...

Страница 12: ...ck for visible cable damage Use a different USB C cable use a different USB Outlet adapter Hydrogen water is generating a fine mist Unstable electrodes Turn off the power clean and stabilize pg 10 Small leaks to the oxygen outlet Drying dried electrode part Pour warm water less than 140 F 60 C to use the electrode area sufficiently wet for more than 10 minutes Operation sound when hydrogen water i...

Страница 13: ...ter ORP 450 900 m V Use tem perature 10 40 50 104 ၀F Body weight About 850g About 1 9 lbs Size W 216 D 103 H 268m m W 8 5 x D 4 05 x H 10 55 in Operating tim e 10 m inutes or 20 m inutes Charge tim e About 90 150 m in Rated voltage DC 5V 2A Product Specification 13 ...

Страница 14: ...r malfunctions please contact the dealer or customer service 4 When requesting the repair service see above for the contact information 5 After purchasing the Echo H2 Pitcher please fill out the form of the warranty and keep it handy Warranty details 1 This product will be repaired in cases where the product is defective within the warranty period 2 During the warranty period if the following occu...