IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS BEFORE USING

     DANGER!

WATER TEMPERATURE SETTING

Safety and energy conservation are factors to be considered when selecting the 

water temperature setting. Water temperatures above 125°F can cause severe 

burns or death from scalding. The thermostat is adjusted to its lowest temperature 

position when shipped from the factory. Be sure to read and follow the warnings 

outlined on the label pictured below.

The chart shown above may be used as a guide in 

determining the proper water temperature for your 

home.

         

DANGER: Households with small children, disabled, 

or elderly persons may require a 120°F. or lower 
temperature setting to prevent contact with”HOT” water.

Maximum water temperature occurs while burner is on. 

To find water temperature being delivered, turn on a hot 

water faucet and place a thermometer in the water stream 

and read the thermometer.
The temperature of the water at the outlet of the water 

heater can be regulated by setting the temperature on the 

control panel. The control panel was set at 110°F before it 

was shipped from the factory.

The illustration to the bottom left illustrates the control 

panel and how to adjust the water temperature.

NOTICE:

 When this water heater is supplying general 

purpose hot water requirements for use by individuals, a 

thermostatically controlled mixing valve for reducing point 

of use water temperature is recommended to reduce the 

risk of scald injury. Contact a licensed plumber or the local 

plumbing authority for further information.

NOTICE:

 The factory setting allows operating temperatures 

between 90°F and 140°F.

NOTICE: 

This is a manual water heater. This means that 

the temperature must be set and regulated from the front 

control panel on the water heater and 

NOT

 at your sink 

or shower. Adjusting the water temperature from the sink 

will lower the pressure activation point and turn the water 

heater off. 

DO NOT

 adjust water temperature via your sink 

or shower. You 

MUST 

adjust the temperature at the face 

of the water heater using the control panel. 

The FVI12 is 

a pressure activated manually operated tankless water 

heater. 

Water Temperature

120°F
125°F
130°F
135°F
140°F
145°F
150°F
155°F

Time To Produce a Serious Burn

More than 5 minutes

1 1/2to 2 minutes

About 30 seconds
About 10 seconds

Less than 5 seconds
Less than 3 seconds

About 1 1/2 seconds

About 1 second

Time/Temperature Relationship in Scalds

Table courtesy of Shriners Burn Institute

Water temperature over 125°F can cause severe burns 

instantly or death from scalds. Children, disabled and elderly 

are at highest risk of being scalded. See instruction manual 

before setting temperature at water heater. Feel water 

before bathing or showering. Temperature limiting valves are 

available, see manual.

SAFETY PRECAUTIONS

Safety

Содержание FVI12 Series

Страница 1: ...IS SUBJECT TO CHANGE WITHOUT NOTICE PLEASE VISIT WWW ECCOTEMP COM SUPPORT FOR MORE INFORMATION Phone 866 356 1992 Email Support eccotemp com Address 315 A Industrial RD Summerville SC 29483 English S...

Страница 2: ...IS SUBJECT TO CHANGE WITHOUT NOTICE PLEASE VISIT WWW ECCOTEMP COM SUPPORT FOR MORE INFORMATION Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator Phon...

Страница 3: ...instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity...

Страница 4: ...perature Controls The temperature must be set and regulated from the font control panel and not your sink See page 26 for more info MODEL FLOW U M MAXIMUM TEMPERATURE RISE IN DEGREES 80 75 70 65 60 55...

Страница 5: ...aintenance service or warranty of this water heater should be directed to the seller from whom it was purchased If additional information is required refer to the section on If You Need Service Do not...

Страница 6: ...portant There are many important safety messages in this manual and on your water heater Always read and obey all safety messages This is the safety alert symbol Recognize this symbol as an indication...

Страница 7: ...d at least annually thereafter Refer to the Care and Cleaning section of this manual for more information regarding flue terminal inspection WARNING Gasoline as well as other flammable materials and l...

Страница 8: ...tory The illustration to the bottom left illustrates the control panel and how to adjust the water temperature NOTICE When this water heater is supplying general purpose hot water requirements for use...

Страница 9: ...ry or fire do not connect the water heater to a fuel type not in accordance with the water heater data plate propane for propane water heaters and natural gas for natural gas water heaters These water...

Страница 10: ...to overheating fire flood physical damage or if the gas supply fails to shut off Read this manual entirely before installing or operating the water heater Use this water heater only for its intended p...

Страница 11: ...ITHOUT NOTICE PLEASE VISIT WWW ECCOTEMP COM SUPPORT FOR MORE INFORMATION Phone 866 356 1992 Email Support eccotemp com Address 315 A Industrial RD Summerville SC 29483 English Support Eccotemp com hel...

Страница 12: ...nd a top clearance of 12 inches must be maintained The vent pipe can be up to 32 ft in length with one elbow The vent pipe should be installed with a flame retardant wall thimble Owner must refer to v...

Страница 13: ...tion suitable for Category III venting Failure to install and properly vent the water heater to the outdoors as outlines in the Venting Section of this manual can result in unsafe operation Owner must...

Страница 14: ...not less than one square inch per 2 000 BTUH of the total input rating of all the appliances in the enclosure If ducts are used the minimum dimensions of rectangular air ducts shall not be less than...

Страница 15: ...ddress 315 A Industrial RD Summerville SC 29483 English Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator NOTICE The National Fuel Gas Code NFGC manda...

Страница 16: ...required for long pipe runs and outlet fitting s water pressure drops To maintain proper performance ensure sufficient water supply pressure The Required Water Pressure Min Operating Water Pressure 2...

Страница 17: ...ould be installed in the gas line close to the water heater The National Fuel Gas Code NFGC mandates a manual gas shut off valve See NFGC for complete instructions A sediment trap should be installed...

Страница 18: ...for purchase at www eccotemp com For safe operation of the water heater be sure that The pressure rating of the relief valve must not exceed 150 psi the maximum working pressure of the water heater as...

Страница 19: ...uns The maximum recommended unsupported span should be no more than five 5 feet Support isolation hanging bands should be used DO NOT use wire See diagram below DANGER Failure to install the vent adap...

Страница 20: ...ensate formed during operation of the water heater evacuated from the water heater A per foot upward slope is acceptable when it is not possible to vent with a downward slope however a UL approved Cat...

Страница 21: ...4 below 4 horizontally from or 1 above any door operable window or gravity air inlet into any building 3 above any forced air inlet within 10 Vent Clearances When Heater is Installed Indoors Illustra...

Страница 22: ...tion Instructions www novaflex com information_centre zflex 032 Vent 20Residential Z Vent 20Installation 2Guide 20CURRENT pdf Z Flex Ventilation Parts https www eccotemp com installation Part Name Des...

Страница 23: ...o any wall thickness from 3 1 2 to 6 thick If the wall is thicker than 6 the wall thimble may be extended using a piece of 6 diameter snaplock or welded seam galvanized pipe up to 6 long Select the la...

Страница 24: ...akage breaker is recommended GFCI Keep any excess of the power supply cord on the outside of the water heater WARNING Field wiring connections and electrical grounding must comply with local codes or...

Страница 25: ...ructions included with the kit must be carefully followed Hot and Cold Pipe Insulation Installation For increased energy efficiency use pipe insulation Please install the insulation according to the i...

Страница 26: ...w B SIDE INSTALLATION 1 Aim the holes in the water heater onto the expansion screws hang it up and screw the nuts tightly 2 Put the vent pipe through the holes in the wall and connect the elbow with t...

Страница 27: ...ning materials rags etc clear of the heater and vent piping Water heater is properly attached to the wall B Water Supply Water supply has sufficient pressure Air purged from water heater and piping Wa...

Страница 28: ...NOT touch any electric switch DO NOT use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas suppl...

Страница 29: ...if the water heater has not been used for a considerable period of time the repeat of the above procedures may be required due to accumulated air inside the gas pipe Safety Precautions If there is any...

Страница 30: ...ential if the temperature is set too high Households with small children disabled or elderly persons may require a 120 F or lower temperature setting to prevent contact with HOT water Output temperatu...

Страница 31: ...w children to operate or otherwise handle the water heater DANGER Before manually operating the relief valve make certain no one will be exposed to the danger of the hot water released by the valve Th...

Страница 32: ...ter out of the water heater 1 Close the gas shut off valve s 2 Close the water shut off valve 3 Turn the on off switch to the OFF position and disconnect breaker at least 10 seconds after step 1 4 Ope...

Страница 33: ...ow these instructions while draining the water heater can cause serious damage to the water heater as well as personal injury including scalding Draining your Water Heater CONTINUED 6 Month Cleaning R...

Страница 34: ...models using natural or liquid propane gas Some items may not apply Contact Eccotemp to place orders for any parts All parts orders should include The model and serial number of the water heater from...

Страница 35: ...pen hot water faucet completely The main burner goes off when incoming water volume is inadequate Water piping is frozen Allow piping to thaw No electricity or water supply is cut off Check that prope...

Страница 36: ...if the switch or fan is damaged or loose E7 Short Circuit of Air Pressure Switch Motor fan detects a short circuit in air pressure switch Check if the switch is damaged or loose If the error code rema...

Страница 37: ...r than the heat exchanger Labor not included 2 Limited additional Ten Year replacement years 1 through 10 on the heat exchanger when the Product is used in a single family dwelling Labor not included...

Страница 38: ...lute discretion will settle the warrant claim of such defect malfunction or failure to conform to this Warranty In order to make a claim under this Warranty The Owner must notify Eccotemp of the failu...

Страница 39: ...T IS SUBJECT TO CHANGE WITHOUT NOTICE PLEASE VISIT WWW ECCOTEMP COM SUPPORT FOR MORE INFORMATION Phone 866 356 1992 Email Support eccotemp com Address 315 A Industrial RD Summerville SC 29483 English...

Страница 40: ...T IS SUBJECT TO CHANGE WITHOUT NOTICE PLEASE VISIT WWW ECCOTEMP COM SUPPORT FOR MORE INFORMATION Support Eccotemp com help desk Shop Online Eccotemp com products Store Locator Eccotemp com locator Pho...

Отзывы: