Ecco 6221000 Series Скачать руководство пользователя страница 3

920-0014-00 Rev. C

Page 3 of 5

            

Notes:

1.  Larger wires and tight connections will provide longer service life for components.  For high current wires it is highly 

     recommended that terminal blocks or soldered connections be used with shrink tubing to protect the connections.  

     Do not use insulation displacement connectors (e.g., 3M Scotchlock type connectors).  

2.  Route wiring using grommets and sealant when passing through compartment walls.  Minimize the number of 

     splices to reduce voltage drop.  High ambient temperatures (e.g., under-hood) will significantly reduce the current 

     carrying capacity of wires, fuses, and circuit breakers. All wiring should conform to the minimum wire size and other

     recommendations of the manufacturer and be protected from moving parts and hot surfaces.  Looms, grommets, 

     cable ties, and similar installation hardware should be used to anchor and protect all wiring.

3.  Fuses or circuit breakers should be located as close to the power takeoff points as possible and properly sized to  

 

     protect the wiring and devices.

4.  Particular attention should be paid to the location and method of making electrical connections and splices to

     protect these points from corrosion and loss of conductivity. 

5.  Ground termination should only be made to substantial chassis components, preferably directly to the vehicle

     battery.

6.  Circuit breakers are very sensitive to high temperatures and will “false trip” when mounted in hot environments or 

     operated close to their capacity. 

Wiring Instructions:

Important:

 

Disable power before wiring up the bar.

Important! 

This unit is a safety device, and it must be 

connected to its own, separate fused power point to

assure its continued operation should any other electrical 

accessory fail.

The wiring for the strobe bar is as shown in Figure 3 below. 

All wiring should be a minimum of 18AWG. The positive 

line must have a 10 amp fuse. A switch may be used to 

control the on/off function. 

FUSE (10 AMP)

(USER SUPPLIED)

SWITCH

(USER SUPPLIED)

GROUND

GROUND

ORA

RED

GRN

BLACK

ORANGE WIRE:

 

NO CONNECTION = DOUBLE FLASH

 

GROUNDED = QUAD FLASH

GREEN WIRE:

 

NO CONNECTION = HIGH INTENSITY

 

GROUNDED = MED. INTENSITY

Figure 3

Содержание 6221000 Series

Страница 1: ...ice does not ensure all drivers can or will observe or react to a warning signal Never take the right of way for granted It is your responsibility to be sure you can proceed safely before entering an...

Страница 2: ...end of one of the slots on the base and slide into position Repeat for the other three bolts and place the rubber spacers onto the bolts These spacers mount between the bottom of the strobe bar and th...

Страница 3: ...as possible and properly sized to protect the wiring and devices 4 Particular attention should be paid to the location and method of making electrical connections and splices to protect these points f...

Страница 4: ...tube holder and pulling up Plug in the new tube assembly See Figure 4 Description Part No Replacement Dome Lens Amber R5101LA Replacement Dome Lens Blue R5101LB Replacement Dome Lens Clear R5101LC Rep...

Страница 5: ...THE IMPLIED WARRANTIES FOR MER CHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY EXCLUDED AND SHALL NOT APPLY TO THE PRODUCT BUYER S SOLE AND EXCLUSIVE REMEDY IN CONTRACT TORT OR UNDER ANY O...

Страница 6: ...ca el derecho de paso Es su responsabilidad asegurarse de que puede continuar en forma segura antes de ingresar a una intersecci n conducir con tr nsito que se desplaza en direcci n opuesta reaccionar...

Страница 7: ...remo de una de las ranuras de la base y desl cela hasta la posici n Repita el procedimiento para los otros tres pernos y coloque los separadores de caucho sobre los pernos Estos separadores se colocan...

Страница 8: ...s 4 Se debe prestar especial atenci n a la ubicaci n y al m todo de efectuar las conexiones y los empalmes el ctricos para proteger contra estos puntos contra la corrosi n y la p rdida de conductivida...

Страница 9: ...evo conjunto del tubo Consulte la figura 4 Descripci n N de pieza Lente de la c pula de repuesto color mbar R5101LA Lente de la c pula de repuesto color azul R5101LB Lente de la c pula de repuesto tra...

Страница 10: ...NTE SE EXCLUYEN LAS GARANT AS IMPL CITAS DE COMERCIABILIDAD O APTITUD PARA UN PROP SITO EN PARTICULAR QUE NO SE APLICAR N AL PRODUCTO EL NICO Y EXCLUSIVO REMEDIO DEL COMPRADOR CON RESPECTO AL CONTRATO...

Страница 11: ...it pas que tous les conducteurs verront le signal d avertissement ni qu ils agiront en cons quence Ne tenez jamais la priorit pour acquise Vous tes tenu de vous assurer que vous pourrez agir en toute...

Страница 12: ...a base et faites le glisser pour le mettre en place R p tez cette tape avec les trois autres boulons et placez les espaceurs en caoutchouc sur les boulons Ces espaceurs s installent entre la partie in...

Страница 13: ...uli rement attention l emplacement et la m thode relative aux raccordements lectriques et aux pissures pour prot ger ces points de la corrosion et de la perte de conductivit 5 Les raccords de mise la...

Страница 14: ...ant vers le haut Branchez le nouvel ensemble de tube Voir Figure 4 Description R f rence Lentille de d me de rechange ambre R5101LA Lentille de d me de rechange bleue R5101LB Lentille de d me de recha...

Страница 15: ...E LES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU D APTITUDE UN USAGE PARTICULIER SONT EXCLUES ET NE S APPLIQUERONT PAS AU PRODUIT LE SEUL ET UNIQUE RECOURS DE L ACHETEUR CONTRE LE FABRICANT CONCERNAN...

Отзывы: