Door/ash pit/cleaning plug and hob cleaning plug seals should be replaced when showing signs of wear 
or every two years whichever comes first.  Rope seals are not covered by the manufacturer’s warranty. 
 

10. FINISHES 
 

On initial firing and perhaps three to five firings after the initial period, your stove will produce what 
would appear to be toxic fumes and is often mistaken for smoke leaking out of the appliance.  The paint 
on the appliance will be “stoved” or cured by your early firings of the appliance.  Do not be concerned 
that this smoke (which does not smell as wood smoke does, it has a factory chemical smell association 
with it). 
 
Please ensure that the room is adequately ventilated and allow the smoke to dissipate in due course 
without adding more fuel at that time. 
If the paint finish should change colour and become grey or white in appearance due to mis-use or over 
heating you should approach your Ecco Stove dealer who will provide you with spray aerosol paint in the 
appropriate colour to make a paint repair. 
The Ecco Stove is produced from a self coloured material and as such variations in colour and texture of 
that material may be evident but adding to the uniqueness of the product, unless ordered as a pre-
factory painted or as ready for paint on site finish to co-ordinate with home decor. 

 
11. AIR CONTROLS 
 

Your Ecco Stove has three systems of air inlets for combustion, however, these have been permanently 
fixed to ensure smokeless operation.  Do not attempt to adjust these permanently fixed air controls. 

 
11A. TERTIARY AIR 

 
The aerated back plates provide tertiary air from a permanently open air inlet at the back of the stove.  
This air supply has no facility for being closed and is set permanently open.

 

 
Tertiary air is introduced to put the level of the air wash / baffle to re-combust volatiles before they exit, 
unburnt, into the double pass contra flow flue ways and chimney flue. 

 

 

 
 
 
 

Содержание E730

Страница 1: ...D002 TESTED TO EN15250 AND EN13240 CAUTION HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS SEE DATA PLATE AND INSTRUCTIONS 1 INTRODUCTION 2...

Страница 2: ...R SUMMER 22 PAINT FINISHES 23 ASSEMBLY 22A HEARTH LOAD BEARING 22B HEARTH DECCORATIVE 24 TECHNICAL A OUTPUTS B WEIGHT C AIR SUPPLY D EXTRACTOR FANS E FLUE DRAUGHT F FLUE GAS MASS G FLUE GAS TEMPERATUR...

Страница 3: ...cco Stove Foster House 2 Redditch Road Studley B80 7AX United Kingdom T 44 0 1527 857 814 E sales eccostove com W www eccostove com Patent pending USA Canada Europe Russia UK Patent nos 2467433 249888...

Страница 4: ...installation and use of the Ecco Stove is regulated by installation regulations specific to the country it is to be installed in building regulations in the UK The installer must be aware that all loc...

Страница 5: ...ch the appliance is situated Radiant heat is emitted by heat from the external surfaces and initial heat from the front glass door panel 4 FLUE OUTLET Your Ecco Stove is only delivered with a top flue...

Страница 6: ...not blacken However high temperature 150 C burning using the secondary air control will clear the glass 200 C is the optimum operating temperature 7 AIRATED BACK PLATE The back panels pre drilled ver...

Страница 7: ...adequately ventilated and allow the smoke to dissipate in due course without adding more fuel at that time If the paint finish should change colour and become grey or white in appearance due to mis u...

Страница 8: ...rtiary control will produce clean combustion and clear any the majority of blackening on the door glass apart from a band at the top or fly ash deposits on the inner face of the glass when the stove r...

Страница 9: ...18 approximately 1 5kg The primary air ash pit front should be pulled out 1mm maximum for 30 seconds to bring flames into view then closed The next 1 5kgs of wood can now be added in the same way Thi...

Страница 10: ...firing warning If when re firing re fuelling or lighting the Ecco stove it must be fired up to 150 C to 200 C for each new wood load for proper combustion if allowed to tick over below this temperatu...

Страница 11: ...Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt...

Страница 12: ...oduce minimum smoke Fuel loaded to be maximum 150mm diameter and 300mm maximum length Ideally re fuel on a bright fire If the fire has burned down to sparse embers the stove may be re fuelled with two...

Страница 13: ...ht should be 175mm in the diameter High temperature hot face inner linings or coatings are suitable materials but ideally with a maximum flue area of 225 x 225mm Pumice hot face linings with insulatio...

Страница 14: ...and sooting in the flue ways Such conditions must be rectified by improving flue performance immediately Clean any tar deposits off the door glass b Repairs or replacements must be carried out by a co...

Страница 15: ...painted This is normal and will only last for a few high firings Ventilate the room well until the smell has cleared 22 ASSEMBLY The Ecco Stove is delivered in 7 main structural parts being bottom sec...

Страница 16: ...with an should be lifted in with a proprietary lifting frame All other items should be lifted by two or more people PARTS A LOWER BOTTOM PART To be placed on level structural hearth this section must...

Страница 17: ...o bed into place Ba Fit the cast iron grate into the recess within the Silicon Carbide grate section with the upstand to the back of the stove to retain the back baffle board C RIGHT SIDE This section...

Страница 18: ...ear of the stove with the V shape forming a void around the tertiary air intake Position the vermiculite spacer blocks for E730 Model flat against the back section such that the pre drilled vermiculit...

Страница 19: ...ions before fitting the top section The flat gasket tape must be forward toward the middle of the stove The hinged ladder back tape is to be adhered to the back of the baffle brick and the top of the...

Страница 20: ...locate the sections beneath it with the locating pips Add all cleaning plugs into place L FLUEING The stove may be connected with a 150mm stove pipe to the flue it will operate on SEE SECTION 19 FLUE...

Страница 21: ...t Dampers may be necessary if the flue draught is in excess of 0 4 water gauge This pipe must include a soot door access plate within 200 mm of the stoves top i Heat energy stored 120 7 MJ j Co concen...

Страница 22: ...tove 1 x Bottom section silicon carbide Ashcan 2 x alloy cleaning pugs 1 x grate section silicon carbide 1 x cast iron fixed grate 2 x side sections silicon carbide 1 x back section silicon carbide 1...

Страница 23: ...ight EccoStove2015 Ecco Stove Foster House 2 Redditch Road Studley B80 7AX United Kingdom T 44 0 1527 857 814 E sales eccostove com W www eccostove com Patent pending USA Canada Europe Russia UK Paten...

Страница 24: ...product has been installed by a recognised in Country registered installer for its type e g HETAS in the UK The product must be operated in line with the operation manual The product must be built in...

Страница 25: ...The Company reserves the right to replace parts as deemed fit or replace the appliance if so decided Replacement parts are free of charge but labour to install such parts is not covered by this warran...

Страница 26: ...ited copyright EccoStove2015 Ecco Stove Foster House 2 Redditch Road Studley B80 7AX United Kingdom T 44 0 1527 857 814 E sales eccostove com W www eccostove com Patent pending USA Canada Europe Russi...

Страница 27: ...O STOVE WARRANTY REGISTRATION ECCO STOVE MODEL E730 ECCO STOVE SERIAL NUMBER INSTALLED BY ADDRESS POSTCODE OR ZIPCODE TELEPHONE NUMBER INSTALLERS REGISTERED BODY AND NUMBER DATE THE ECCO STOVE WAS INS...

Отзывы: