background image

N

P

P

P

P

1

0

0

F

2

P

P

P

P

N

P

P

P

P

N

0 6

5.  How to select the Relay for the PUSH BUTTON input.  

The 

Push Button Input

 can activate Relay-1 or Relay-2 according to the function that was chosen for the relay.  

The factory default setting for the Push Button Input is to activate RELAY-1 according to the function chosen.  
You can change this setting by SMS command as follows: 

The letters “ PPPP ” represent the 4 digit PASSWORD.   
The letter “ N “ represents the numbers 1 or 2 for Relay-1 or Relay-2 accordingly.  

 

The unit will send confirmation SMS to confirm

.   

6. How to choose the Relays’ function; Pulse or Latch  

For each one of the relays 1 and 2 you can choose one of the following two functions;  
MOMENTARY (PULSE) or LATCH function (ON / OFF).  
The factory default setting for both the relays is a MOMENTARY function (with a 4 second PULSE). 
You can change the sending the SMS command as follows:   
 
 
The letters “ PPPP ” represent the 4 digit PASSWORD.   
The letter “ N “ represents the Number 1 or 2 for Relay-1 or Relay-2. 
The letter “ F “ represents the FUNCTION,  1 for Momentary or 2 for Latch. 

The unit will confirm by SMS message to the sender accordingly

.   

 

7.  How to set the Relays’ PULSE time interval 

For each one of the relays 1 or 2 you can choose the time interval of the pulse, for the momentary function.  
The factory default setting for both the relays is a 4 second PULSE. 
You can choose the TIME interval for each one of the relays by SMS command as follows: 

 

The letters “ PPPP ” represent the 4 digit PASSWARD.   
The letter “ N “ represents the Number 1 or 2 for Relay-1 or Relay-2. 
The letter “ T “ represents the PULSE time: 
 
Enter:  0   => for ½ a second pulse time.  
Enter:  1   => for 1 second pulse time. (Factory Default for Relay 2). 
Enter:  2   => for 2 second pulse time.  
Enter:  3   => for 3 second pulse time.  
Enter:  4   => for 4 second pulse time. (Factory Default for Relay 1).   
Enter:  5   => for 5 second pulse time.  
Enter:  6   => for 6 second pulse time.  
Enter:  7   => for 7 second pulse time.  
Enter:  8   => for 

10

 second pulse time.  

Enter:  9   => for 

15

 second pulse time.  

The unit will send confirmation SMS to confirm accordingly.   

 

8.   To Lock & Unlock the unit;  

The unit can be LOCKED so that it will not operate or make any calls and announce “wrong command” for any attempt 
to make a call or open the gate.      
To LOCK or UNLOCK the unit send the following SMS command: 
 

 

 
The letters “ PPPP ” represent the 4 digit PASSWORD.   
The letter “ N ” represent “ 1 “  for  LOCK and “ 2 “ for UNLOCK.  
The unit will confirm by SMS to the sender that says: “ 

The system is locked

”  or  “

The system is unlocked

 “ accordingly.  

 
 

Содержание COMMUNICATOR GSM18V82

Страница 1: ...the gate If the person that called was not one of the authorized users it will just hang up and do nothing 4 The SIM CARD You would need a MINI size SIM card to be used with this unit Insert the SIM...

Страница 2: ...Door Station Model DS 12 The push button is not supplied with the unit and can be ordered separately Optional Relay 2 Com Relay 1 N O 12V 24V Ac Dc Min 2Amp Power Supply EXIT Push Button Relay 1 Com...

Страница 3: ...following example is to add the first three phone numbers and delete the fourth one 9999A001 0395720535 A002 0395720555 A003 0395720535 D004 The system will confirm by SMS message to the sender as fo...

Страница 4: ...command sent followed by the word CONFIRMED or FAILED at the end of the message How to Cancel or Activate the SMS service in the unit You can Cancel or Activate the SMS service of the unit by sending...

Страница 5: ...et the Relays PULSE time interval For each one of the relays 1 or 2 you can choose the time interval of the pulse for the momentary function The factory default setting for both the relays is a 4 seco...

Страница 6: ...th Hold commands for both the relays as follows 9999 03 12 03 22 10 How to limit the Talking Time You can select and limit the talking time with the visitor by SMS command The factory default limit ti...

Страница 7: ...he PASSWORD The factory default password is 9999 You can change the password by sending the following SMS message The letters P P P P represent the old password The letters W W W W represent the new p...

Отзывы: