Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-Z8910SP User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
35
Send:
FE 01 36 FF
Return: FB 36 Uart_holdtime
Send: FE 01 36 FF
Return: FB 36 64
Configuration instruction format:
Command format
Command example
Send: FD 01 36 Uart_holdtime FF
Return: FA 36
Send: FD 01 36 64 FF
Return:FA 36
Uart_holdtime: The unit of 1
~
255 is 10ms, the default parameter is 100, that is, the serial port will keep waking up for
100*10ms after waking up, and then going to sleep after 1000ms.
6.5.26 Configure endpoint information
Read command format:
Command format
Command example
Send:
FE 05 37 FF
Return: FB 37 Endpoint_info
Send: FE 05 37 FF
Return: FB 37 01 FE B0
05 04
Configuration instruction format:
Command format
Command example
Send: FD 05 37 Endpoint_info FF
Return: FA 37
Send: FD 05 37 01 FE B0
05 04 FF
Return: FA 37
Endpoint_info: 5-byte length data format is endpoint clusterId_H clusterId_L profileId_H profileId_L The default
parameters are endpoint 0x01, clusterId 0xfeb0, profileId 0x0504.
endpoint
clusterId
profileId
clusterId_H
clusterId_L
profileId_H
profileId_L
01
FE
B0
05
04
6.5.27 Trust Center Connection Key
Read command format:
Command format
Command example
Send:
FE 10 38 FF
Return: FB 10 TrustCentLinkKey
Send: FE 10 38 FF
Return: FB 38
5A 69 67 42 65 65 41 6C
6C 69 61 6E 63 65 30 39
TrustCentLinkKey: 16 bytes in length, the default value is the default key of the ZigBee Alliance, and its value is 0x5A
0x69 0x67 0x42 0x65 0x65 0x41 0x6C 0x6C 0x69 0x61 0x6E 0x63 0x65 0x30 0x39
Note: This product uses the default trust center connection key of the ZigBee Alliance, and currently does not support
configuration changes.