Chengdu Ebyte Electronic Technology Co.,Ltd.
E180-Z8910SP User Manual
Copyright ©2012–2021
,
Chengdu Ebyte Electronic Technology Co.,Ltd.
17
type
and sleeping terminal;
Channel
Read/Write
CH11
~
26
The physical channel where ZIGBEE works
;
Send mode
Read/Write
0
、
1
、
2
、
3
、
4
、
5
The transmission modes of the configuration module
are: broadcast mode, multicast mode, short address on
demand mode, long address on demand mode, protocol
on demand, and protocol multicast. For details, please
refer to the corresponding mode function introduction;
Output
mode
Read/Write
0
、
1
、
3
、
4
Configure the data output mode of the module,
respectively:
Penetrate;
Data + short address;
Data + RSSI;
Data + short a RSSI;
Transmit
power
Read/Write
-3~11dbm
The output power of the module requires high power
consumption, and the transmission power can be
reduced to save the average power consumption when
the distance is not required;
Remote
configuratio
n ID
Read/Write
2 Byte
Used to judge whether the data received wirelessly in
the air is a remote configuration command. Customers
can change the unlimited configuration ID according to
their needs. The default is A8 8A;
Local
network
group
number
Read/Write
1
~
254
Used to configure the group number of the device in the
network
;
Target
network
group
number
Read/Write
1
~
254
Used to configure the group number of the
corresponding target when the device is multicast;
Wake-up
period
(sleep time)
Read/Write
1
~
2010S
Used to configure the wake-up period of the terminal
sleeping device. The larger the period, the lower the
overall power consumption, but the greater the delay in
receiving data;
Lost parent
node
reconnectio
n cycle
Read/Write
1
~
2010S
When the parent node is lost (the coordinator is powered
off), the terminal device will reconnect to the previous
network at regular intervals
;
Maximum
number of
reconnectio
ns
Read/Write
0
~
255 times
After the parent node is lost, the maximum number of
reconnections. If the reconnection has not been
successful, the previous network information will be
cleared, and the new network will be rescanned. The
scanning period is equal to the reconnection period;
IO status
Read/Write
High/low
Access/control module GPIO channel level status;
PWM
Read/Write
1us
~
1700ms
The duty cycle and period of the PWM channel of the